Records from 2016 to 2024. Most recent: inspection, 7 December 2024.
Inspection history · 8
7 December 2024
In-Service Inspection · Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8044587
22 June 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7939912
19 April 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7433994
7 May 2021
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7191542
9 August 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6778105
6 October 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6017530
6 October 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6017696
25 September 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6005984
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 December 2024
Resolved
The master shall ensure that ship's personnel continuously monitor cargo operations. where possible, the ship's draught shall be checked regularly during loading or unloading to confirm the tonnage figures supplied. Each draught and tonnage observation shall be recorded in cargo logbook. If significant deviations from the agreed plan are detected, cargo or ballast operations or both shall be adjusted to ensure that the deviations are corrected. it was reported that the vessel was observed to have a significant list and overdraft from the original loading plan. While in attendance, draft surveyor identified approximately 750 metric tons that were unaccounted for in vessel's signed loading plan. PSCO observed forward echo depth sounder alarming on bridge and crew unable to account for additional tonnage.
74SOLAS(20)VI/7.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2021
Resolved
07110 - Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO discovered ships water-mist system in manual mode. The crew stated that the last time the system was serviced was 6 days ago and that the electrician likely left it in that manner.
74 SOLAS (14) II-2/14.2.1.2
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2021
Resolution: Recieved Class report attesting to rectification of deficiencies.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2021
Resolved
99101 - Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position with a valve protection cap in place. PSCO observed multiple oxygen bottles stored on deck tied to a rail and multiple oxygen and acetylene bottles in a storage room without caps and not in a rack.
46 CFR 147.60(b)
17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2021
Resolution: Received Class report attesting to rectification of deficiencies.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 May 2021
Resolved
07199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the purifier room alarm did not display and create computer entry log.
74 SOLAS (14) I/11(a)
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2021
Resolution: Recieved Class report attesting to rectification of deficiencies.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 May 2021
Resolved
04103 - Alleyways, stairways, and exits giving access to the muster embarkation stations shall be lighted. Multiple emergency lighting arrangements leading to embarkation stations were found inoperable.
74 SOLAS (14) III/11.5
16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2021
Resolution: Recieved Class report attesting to rectification of deficiencies.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 7 May 2021
Resolved
15110 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Crew was unable to provide service records for the maintenance of the water-mist fire extinguishing system. Additionally, procedures for testing/operation of the water-mist system were inadequate to prevent the crew from maintaining the system in a state of operational readiness. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The Captain of the Port questions the adequacy of the vessel's SMS under the ISM Code. An internal audit is required within 90 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the report to the USCG when completed.
74 SOLAS (14) IX/3.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2022
Resolution: Received ISM internal audit.
Electrical › Electric Generation Source (emergency) › Generator
Issued 25 September 2016
Resolved
Each emergency generating set arranged to be automatically started shall be equiped with a second source of energy unless manual starting can be demonstrated to be effective. PCPO observed that the manual start was not able to start the emergency generator, proving to be ineffective. The result is the emergency generating set does not have a second source of energy as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2016
Resolution: Survey report received. Second set of independent batteries installed with a means of charging.