MAURY USCG vessel records
← All vessels

SILVER SKY

SILVER SKY is a freight ship. The Coast Guard has recorded 13 inspections since 2018, most recently in July 2026, along with 14 deficiencies and 2 operational controls.

Records from 2018 to 2026. Most recent: inspection, 23 July 2026.

Built
Not recorded
Last inspected
23 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9448140
3E3734
1081846
Flag
PANAMA
Maury page id
psix-1081846

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (2018–2026)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it12300 - Dead Weight, Ton
27067 - Displacement, Ton
47090 - Convention (Subpart B), Gross Ton
14315 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 13

23 July 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8445720
22 July 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8445378
2 February 2026 PSC A
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8300770
10 June 2025 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8155707
3 June 2025 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8147774
31 October 2024 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8027831
31 January 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7857297
4 February 2023 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7628744
17 September 2019 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6813599
13 September 2019 ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6807505
3 June 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6702338
8 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6658157
17 February 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6354716

Deficiency record · 14

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 3 June 2025 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THESHIP IS MAINTAINED IN ACCORDANCE WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS ESTABLISHED BY THE COMPANY. THE TECHNICAL AND OPERATIONAL NATURE OF THE DEFICIENCIES NOTED BELOW PROVIDE OBJECTIVE EVIDENCE OF A SERIOUS FAILURE OF THE IMPLEMENTATION OF THE ISM CODE. AND EXTERNAL AUDIT REPORT SATISFACTORY TO THE COAST GUARD MUST BE SUBMITTED PRIOR TO CLEARANCE OF THIS DEFICIENCY.74 SOLAS (20) IX/3 ISM CODE 10.1
Action required: 30 - Ship detained
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Cleanliness of engine room
Issued 3 June 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 3 June 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 3 June 2025 Resolved
THE SAFETY MANAGEMENT SYSTEM SHOULD INCLUDE PROCEDURES ENSURING THAT NON-CONFORMITIES, ACCIDENTS AND HAZARDOUS SITUATIONS ARE REPORTED TO THE COMPANY, INVESTIGATED AND ANALYZED WITH THE OBJECTIVE OF IMPROVING SAFETY AND POLLUTION PREVENTION. PSCO OBSERVED A LACK OF REPORTING OF NON-CONFORMITIES AS PER THE SMS. NON-CONFORMITY FORMS, CORRECTIVE ACTION REQUESTS, AND FOUND ISSUES IN THE ENGINE ROOM WERE NOT COMPLETED OR ROUTED UP TO THE COMPANY, NOR WERE THEY SENT TO COMPANY ON REQUIRED TIMELINE. KNOWLEDGE OF THIS SECTION OF THE SMS WAS HEAVILY LACKING IN THE CREW AND CAPATIN. 74 SOLAS (20)IX/3 ISM CODE 9.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 3 June 2025 Resolved
THE SAFETY MANAGEMENT SYSTEM SHOULD PROVIDE FOR MEASURES THAT THE COMPANY'S ORGANIZATION CAN RESPOND AT ANY TIME TO HAZARDS, ACCIDENTS AND EMERGENCY SITUATIONS INVOLVING ITS SHIP. PSCO OBSERVED EMERGENCY ESCAPE WITHOUT APPROPRIATE ROPE AND HARNESS PROVIDED INSIDE. ROPE WAS NOT MOUNTED ON UPLLEY SYSTEM INSTALLED, AND WAS INSTEAD LOOPED UNSECURED AROUND LADDER ARM, AND HARNESS WAS NOT AVAILABLE IN SPACE. 74 SOLAS (20)IX/3 ISM CODE 8.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 June 2025 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. PSCO OBSERVED EXTENSIVE OIL COLLECTIONS IN ENGINE ROOM. PSCO OBSERVED SPRAYING OIL COMING FROM GENERATOR, LEAKING DIRTY OIL FROM #2 STEERING PUMP, BLACK OIL COLLECTED IN BARREL AND IN SINK WITHIN OIL PURIFYING ROOM, OIL COLLECTED IN CONTAINMENT AROUND TANKS, THICK BLACK OIL IN CONTAINMENT ABOVE THE INCINERATOR, AND OIL IN CONTAINMENT AND ON DECK FLOORS NEAR BILGE. ADDITIONALLY, PSCO OBSERVED DIRTY RAGS, SOME HEAVILY SOAKED WITH OIL, IN ALL SPACES WITHIN THE ENGINE ROOM, INCLUDING THE PURIFYING ROOM AND ECR. PSCO OBSERVED DIRTY AND CLEAN COMBUSTIBLE MATERIALS STORED THROUGHOUT ENGINE ROOM, AS WELL AS OTHER OILED COMBUSTIBLES (SHEETS, STRAPS, AND WOOD). OVERALL CLEANLINESS OF ENGINE ROOM WAS SUBSTANDARD. 74 SOLAS (20)II-2/4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 June 2025 Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCO OBSERVED ALL THREE GENERATORS WITH BLACK OIL IN AND ON SURFACES OF CONTAINMENT; ON THE #3 GENERATOR, METAL SHEET WAS RIGGED TO THE SIDE OF THE GENERATOR USING ROPE TO KEEP SPRAY OF BLACK OIL FROM ESCAPING GENERATOR CONTAINMENT. PSCO OBSERVED LEAKING JACKET WATER ON THE M/E #2, 5, 7 CYLINDER HEADS, PRODUCING A STREAM OF SUSTAINED WATER TO CREATE AND ARC OF AROUND 90° OUTWARDS. PSCO OBSERVED INCINERATOR WITH HEAVILY WORN INSULATION ON THE DOOR, SO TO EXPOSE METAL WIRING. WEARING IN CENTER EXCEEDED 4 INCHES IN DEPTH. 74 SOLAS (20) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2025 Resolved
ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED A STEADY LEAK OF BLACK OIL FROM ON THE #2 STEERING GEAR PUMP. CREW WAS UNABLE TO GET THE STEERING GEAR PUMP TO BECOME OPERATIONAL FOR OVER AN HOUR. REPAIRS WERE COMPLETED TO REGAIN FUNCTIONALITY, WITH CAUSE CLAIMED TO BE COUPLER ISSUE. TEMPORARY REPAIRS MADE, REQUEST CLASS CONFIRMATION. 74 SOLAS (20)II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 June 2025 Resolved
AFTER ANY SURVEY UNDER ARTICLE 14 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURE, EQUIPMENT, ARRANGEMENTS, MATERIAL OR SCANTLING COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED REPAIRS BEING MADE TO THE EQUIPMENT AND TANKS AND ASSOCIATED SYSTEMS THAT WERE NOT APPROVED BY CLASS, INCLUDING REPAIRS DONE TO FUEL TANK USING EPOXY AND FIBERGLASS AND REPAIRS DONE TO A GENERATOR USING A METAL SHEET AND STRAPS, AND DUCT TAPE USED ON FLASHING INSTEAD OF FLASHING TAPE. ICLL ARTICLE 15
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 June 2025 Resolved
SPECIAL CONSIDERATION SHALL BE GIVEN TO THE DESIGN, CONSTRUCTION AND INSTALLATION OF PROPULSION MACHINERY SYSTEMS SO THAT ANY MODE OF THEIR VIBRATIONS SHALL NOT CAUSE UNDUE STRESSES IN THIS MACHINERY IN THE NORMAL OPERATING RANGES. PSCO OBSERVED MOUNT FOR THE EXHAUST SYSTEM FROM THE ENGINE THAT HAD COME LOOSE, AND ITEMS OF METAL AND WOOD HAD BEEN SHOVED BETWEEN THE MOUNTING PLATE IN AN ATTEMPT TO PREVENT VIBRATION RATHER THAN REPAIRS WERE MADE. 74 SOLAS (20) II-1/26.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 3 June 2025 Resolved
MAIN AND EMERGENCY SWITCHBOARDS SHALL BE SO ARRANGED AS TO GIVE EASY ACCESS AS MAY BE NEEDED TO APPARTUS AND EQUIPMENT, WITHOUT DANGER TO PERSONNEL. WHERE NECESSARY, NONCONDUCTING MATS OR GRATINGS SHALL BE PROVIDED AT THE FRONT AND REAR OF THE SWITCHBOARD. PSCO OBSERVED MISSING ELECTRICAL MATTING IN FRONT OF HIGH VOLTAGE PANELS IN PURIFYING ROOM. 74 SOLAS (20) II-1/45.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 6 June 2025
Resolution: Received, reviewed and accepted class report from (ABS) stating the deficiency was rectified. USCG PSC Officers attended vessel and validated that deficiency was rectified. Please see attached Class Report in Documents.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 3 June 2025 Resolved
AN EEBD IS A SUPPLIED AIR OR OXYGEN DEVICE ONLY USED FOR ESCAPE FROM A COMPARTMENT THAT HAS A HAZARDOUS ATMOSPHERE AND SHALL BE OF AN APPROVED TYPE. PSCO OBSERVED EEBD OVER-PRESSURIZED. WORKING PRESSURE MUST BE 21mpa AND BOTTLE WAS AT 24mpa. INSPECTION OF BOTTLE OCCURED 31MAY25. TRAINING CONDUCTED AND BOTTLE REPLACED WITH SPARE. CORRECTED ON THE SPOT. 74 SOLAS (20) II-2/13 FSS CODE CH.3/2.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 June 2025
Resolution: Crew members were able to replace EEBD bottle with spare and conducted training on the spot. Deficiency correct on the spot as observed by PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2025 Resolved
FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS, GALLEY BOUNDARIES AND STAIRWAY ENCLOSURES OTHER THAN POWER-OPERATED WATERTIGHT DOORS AND THOSE WHICH ARE NORMALLY LOCKED SHALL SATISFY THE FOLLOWING REQUIREMENTS; THE DOORS SHALL BE SELF-CLOSING AND BE CAPABLE OF CLOSING WITH AND ANGLE OF INCLINATION OF UP TO 3.5° OPPOSING CLOSURE. PSCO OBSERVED FIRE DOOR ON PURIFYING ROOM TO BE NON-FUNCTIONAL. DOOR LATCH WAS DAMAGED AND WOULD NOT LATCH SHUT UPON CLOSING. REPAIRED ON SCENE AND TESTED FOR OPERATION. 74 SOLAS (20) II-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 June 2025
Resolution: Vessel crew members were able to repair damaged door latch on the spot. Deficiency correct on the spot as observed by PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2025 Resolved
THE CONSTRUCTION OF DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS, WITH THE MEANS OF SECURING THEM WHEN CLOSED, SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME EQUIVALENT TO THAT OF THE BULKHEADS IN WHICH THE DOORS ARE SITUATED. THIS BEING DETERMINED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES CODE. PSCO OBSERVED FIRE DOOR TO STEERING GEAR ROOM HAS GASKET HEAVILY WORN. REPAIRED ON SCENE AND TESTED FOR OPERATION. 74 SOLAS (20) II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 June 2025
Resolution: Vessel crew members repaired worn gasket on fire door leading into the steering gear room. Deficiency corrected on the spot as observed by PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.