← All vessels
ELAR TRADER
ELAR TRADER is a 2010 freight ship. The Coast Guard has recorded 5 inspections since 2019, most recently in November 2025, along with 5 deficiencies.
Records from 2019 to 2025. Most recent: inspection, 18 November 2025.
- Built
- 2010
- Last inspected
- 18 November 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9409534 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6YK9
1083960
Flag
BAHAMAS, THE
—
Maury page id
psix-1083960
Inspections, by type
Years with a record
3 calendar years (2019–2025)
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it12169 - Convention (Subpart B), Net Ton
37781 - Dead Weight, Metric Ton
46927 - Displacement, Metric Ton
24099 - Convention (Subpart B), Gross Ton
37781 - Dead Weight, Metric Ton
46927 - Displacement, Metric Ton
24099 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
18 November 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8267967
19 October 2022
In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7580238
27 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7544594
22 August 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7540389
24 April 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6669089
Deficiency record · 5
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2022
Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While anchored, on 19 October 2022, the vessel was allided with on the starboard side causing visible damage to the hull near the unloaded water line.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 August 2022
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company; in meeting these requirements, the company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken.
VOP-S-05 states in section 1.2, "Inspection and maintenance of life saving and fire-fighting equipment planning and performance of maintenance of the fire-fighting equipment is done as per 'planned maintenance schedule of life-saving and fire-fighting equipment (attachment 1)'." VOP and referenced Attachment 1 does not specify proper testing procedures for testing fixed fire detection systems. As dilineated in deficiency 02, crew does not have quipment to test fire detection. In addition, PSCE observed crew attempting to test heat detection with torch. When PSCE asked about SMS procedures, crew stated they did not have the correct part to test, but only ordered needed equipment today.
VOP-E-04/A "Critical Equipment Testing Schedule" states and shows oily water separator: recirculation valve/pump stop shall be checked by C/E monthly. PSCE observed monthly checks did not include recirculation valves. As dilineated in deficiency 04, recirculation valve is inoperable with records of parts ordered in November 2021. Crew found ordered part onboard, though no plans for replacing were discussed or actions for replacement initiated. Crew has been testing system without flow.
Recommend internal audit with a focus on testing procedures for fixed fire detection, and for testing Oily Water separator. Internal audit to be completed within 30 days.
74SOLAS(20) IX/3.1
ISM Code 10.1, 10.2.1, 10.2.2, 10.2.3
Action Taken: 705ac
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 August 2022
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use; and fire-protection systems and fire-fighting systems and appliances shall be properly tested and inspected.
PSCO observed crew unable to test fire detection systems. Crew stated there is no proper testing equipment onboard.
74SOLAS(14) II-2/14.1
Action Taken: 17ac
26AUG22:
Vessel provided substantial evidence of their inability to obtain IR testing equipment. The requested part is already delivered in Port Everglades. Amended deficiency to next US port.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 August 2022
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Howeer, hold back arrangements fitted with remote release devices of the fail-safe type may be utilized.
PSCE observed hold back line on self-closing door in steering gear room, leading to Emergency Fire-pump.
Cite: 74SOLAS(14) II-2/9.4.2.2
Action Taken: 10c
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 22 August 2022
Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In addition, it shall be provided with alarm arragements to indicate when this level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. In considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the Organization.
PSCO unable to verify operation of OWS due to inoperable recirculation valves. Crew tested alarm without flow, and when asked by PSCOs to test with flow, received high temperature alarm on OCM. Crew could not produce successful test with observable flow, and automatic stop.
Cite: MARPOL I/14.7
Action Taken 17ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.