MAURY USCG vessel records
← All vessels

MAERSK YORKTOWN

MAERSK YORKTOWN is a freight ship. The Coast Guard has recorded 40 inspections since 2017, most recently in December 2025, along with 31 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 16 December 2025.

Built
Not recorded
Last inspected
16 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 December 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9289192
1098024
Flag
UNITED STATES
Maury page id
psix-1098024

Documentation record

Registered dimensions (L × B × D)607.8 ft × 105.6 ft × 55.4 ft
Registered tonnagegross 24,488 / net 10,441
ITC dimensions (L × B × D)607.8 ft × 105.6 ft × 55.4 ft
ITC tonnagegross 24,488 / net 10,441
BuilderSTRALSUND, GERMANY
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsRegistry, Canadian bulk freight
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24488 - Convention (Subpart B), Gross Ton
24488 - Dead Weight, Ton
10441 - Displacement, Ton
10441 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 40

16 December 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8302452
12 December 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8295921
26 October 2025 Annual Inspection · MSP Select Annual Oversight
Physical examination · Activities Europe · Activity 8255380
25 March 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8099744
1 February 2025 Administrative Inspection
Administrative · Activities Europe · Activity 8073092
8 October 2024 Administrative Inspection
Administrative · Activities Europe · Activity 8015996
12 September 2024 Administrative Inspection
Administrative · Activities Europe · Activity 8001206
13 July 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7957243
2 July 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7947081
24 June 2024 MSP COI Oversight · COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 7941139
10 June 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7931583
6 May 2024 Administrative Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 7907143
27 April 2024 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8062799
12 February 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7864140
11 January 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7848027
7 November 2023 Annual Inspection · MSP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7756662
13 October 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7811864
7 July 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7735604
17 May 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7690314
27 February 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7642368
31 January 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7629490
24 January 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626478
1 September 2022 MSP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7527699
16 June 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7496570
7 May 2022 Administrative Inspection
Administrative · Activities Europe · Activity 7445998
6 November 2021 MTSA/ISPS Verification · Annual Inspection · MSP Annual Oversight
Physical examination · Activities Europe · Activity 7333244
20 April 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7178806
19 October 2020 Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight · MSP Select Handover Survey
Physical examination · Activities Europe · Activity 7074526
30 September 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6824186
19 August 2019 COI Inspection · MTSA/ISPS Verification · MSP COI Oversight
Physical examination · Activities Europe · Activity 6787836
18 August 2019 Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 6761289
23 April 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6669082
7 December 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6593464
7 November 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6576361
11 August 2018 Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6507876
27 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6467849
19 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6448949
9 April 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6387663
15 December 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6325033
13 June 2017 Reflagging & Initial Certification · COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6162081

Deficiency record · 31

01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 26 October 2025 Resolved
After any survey of the ship has been completed, no change shall be made in the equipment covered by the survey, without the sanction of the Administration, except the direct replacement of such equipment and fittings. Vessel installed new Oil Content Meter meeting MEPC 107(49). IOPP Form A issued by RO was not updated to reflect this new equipment. MARPOL 73/78 Annex I / Reg 6.4.2
Action required: 15 - Rectify deficiencies by next port
Resolved 29 October 2025
Resolution: Received updated IOPP Form A
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 26 October 2025 Resolved
After any survey of the ship has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey, without the sanction of the Administration, except the direct replacement of such equipment and fittings. Scavenge Air Cooler System tank discharge piping was modified from as built condition. Discharge piping connected to OWS overboard piping beyond OWS was removed by crew. Crew now pumps scavenge air drain tank to sludge tank with portable pumps and hoses and discharges all ashore. The new system should be made permanent, use of portable hoses/pumps will not be authorized by administration. Complete ABS review/approval of modification and new procedures. (See drawings M 134 & M 160) MARPOL Annex I / Reg 14.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2025
Resolved 25 November 2025
Resolution: Verified finding issued in ABS MyFreedom Portal.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 26 October 2025 Resolved
Oil filtering equipment shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 parts per million. In considering the design of such equipment, the Administration shall have regard to the specification recommended by the Organization. Repair holed OWS piping near 3-way valve. In addition, as noted in Item 02, scavenge air drain tank piping to OWS overboard piping removed and blanked off. Maintain seal log/plastic seal and/or permanently secure blank. MARPOL Annex I / Reg 14.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2025
Resolved 8 January 2026
Resolution: ABS finding 771.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2025 Resolved
During testing of auxiliary boiler standby feed pump (following ATP/PSTP procedures), standby feed pump did not turn on as stated in PSTP. Crew reviewed electrical diagrams and identified design which prohibited auto-standby start when breaker F9B & F7B are tripped. Determine with ABS if electrical system/power source requires modification or if PSTP can be updated for pressure switch auto-start only. During inspection, tested auto-start with low pressure to pressure switch (not on PSTP). SOLAS 74am (04 Cons Ed) Ch II-1/46.2
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2025
Resolution: Verified finding issued in ABS MyFreedom Portal.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 26 October 2025 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operations. PSTP procedures were revised by crew/company in July 2025 to Revision 2.2. Complete approval process with ABS engineering. Provide ABS approval letter to USCG-ACTEUR office. SOLAS 74am (04 Cons Ed) Ch II-1/46.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2025
Resolved 8 January 2026
Resolution: ABS finding 772.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 October 2025 Resolved
All electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in the normal manner. Various dead end wires identified in fore peak/bow thruster space near tank gauging system. SOLAS 74am (04 Cons Ed) Ch II-1/45.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 November 2025
Resolution: ABS Finding 774.0
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 26 October 2025 Resolved
The company should ensure that each ship is manned with qualified, certificated and medically-fit seafarers in accordance with the national and international requirements. During review of the crew’s medical certificates, identified 2 crew members on board that had not submitted their medical waivers to the master as per company sign on procedures. Corrected on the spot. SOLAS 74am (04 Cons Ed) CH IX/3.1; ISM Code Part A 6.2.1
Action required: 10 - Deficiency Rectified
Resolved 27 October 2025
Resolution: Discussed ISM requirements with Master.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 October 2025 Resolved
In multi-engine installations which are supplied from the same fuel source, means of isolating the fuel supply and spill piping to individual engines shall be provided. During testing of remote fuel shut-off valves, Main Engine FO inlet valve failed to fully close. Crew replaced spring on quick closing valve and retested satisfactory. SOLAS 74am (04 Cons Ed) II-2 / 4.2.2.5.5
Action required: 10 - Deficiency Rectified
Resolved 27 October 2025
Resolution: Corrected while on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 November 2023 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Port aft hull of lifeboat shows a hairline crack in the gelcoat, which requires further investigation. 74 SOLAS 20 III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2023
Resolved 21 November 2023
Resolution: Hatecke, lifeboat manufacturer, determined hairline crack was only gelcoat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 7 November 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported one-inch diameter hole in Port FW tank. 74 SOLAS 20 I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 21 November 2023
Resolution: Temp repair approved until special survey in August 2024.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 7 November 2023 Resolved
All ships of 3,000 gross tonnage and upwards shall have a 3 GHz radar. Vessel reported inoperable s-band radar. ABS has issued a short-term SLE certificate valid until 10 January 2024. Flag dispensation is granted to the vessel MAERSK YORKTOWN until 10 January 2024. 74 SOLAS 20 V/19.2.7
Action required: 705 - Other - as specified
Due 10 January 2024
Resolved 4 December 2023
Resolution: S-band radar transceiver replaced by authorized tech / sat test conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023 Resolved
The ring, line and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Vessels loadline and draft marks are not legible. ICLL 66 I/8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2023
Resolved 21 November 2023
Resolution: The load line mark and draft mark were both painted in white, with the draft mark painted as much as possible above the water level and found satisfaction by the attending surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 2 September 2022 Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm setpoints, the procedure to be followed, and the expected test result. The fire, heat, and flame detector numbers in the Periodic Safety Procedure (ABS approval date 06May2019) do not correspond with the detector numbers in the Consillium Fire Detection Panel or labeled on board the vessel. Cite: 46 CFR 61.40-10(a) NVIC 01-13 CH-1 Enclosure(2) 3.2.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2022
Resolved 9 September 2022
Resolution: ABS provided preliminary report with finding number.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 September 2022 Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate for key shipboard operations concern the safety of the personnel, ship and protection of the environment. Multiple entries in the Lock-Out Tag-Out (LOTO) log or tags identified on LOTO equipment do not follow the SMS procedure 07-01-02-01.900 found in the LOTO logbook. Cite: SOLAS 2020 IX/Reg 3, ISM Code Part A 7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2022
Resolved 9 September 2022
Resolution: ABS provided preliminary report with finding number.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 7 November 2021 Resolved
Ventilators in position 1 or 2 to spaces below freeboard deck or decks of enclosed superstructures shall have coamings of steel or other equivalent material, substanitally constructed and efficiently connected to the deck. Approx 5 cm from dem, a 2 cm hole was identified in ventilator V3, as indicated on ILLC Lloyd's Registry Form 2026 (ABS equivalent to LL-11-D/stamped by ABS 16Jun2017). ILLC 66/88 Reg 19.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2021
Resolved 2 December 2021
Resolution: Received satisfactory class report.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 19 October 2020 Resolved
Provide letter from the previous flag or the Recognized Organization identifying the approved fire control plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2020
Resolved 25 October 2020
Resolution: Vessel Rep provided letter from RO approving FCP.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 19 October 2020 Resolved
Repair vent in #5 cargo hold to original condition.
Action required: 10 - Deficiency Rectified
Due 19 November 2020
Resolved 21 October 2020
Resolution: Repaired prior to departure with contractor. Pictures attached.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 August 2019 Resolved
The emergency generator set must shut down automatically upon loss of lubricating oil pressure. The EDG did not shut down when simulationg loss of lube oil pressure as per approved PSTPs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 21 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › International Sewage Pollution Prevention Cert.
Issued 7 September 2018 Resolved
The U.S. is not signatory to MARPOL 73/78 Annex IV; an International Sewage Pollution Prevention Certificate may not be issued on behalf of the Coast Guard. ABS has issued this certificate instead of a Statement of Voluntary Compliance to demonstrate compliance. Provide evidence that proper documentation has been issued.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2018
Resolved 12 September 2018
Resolution: Submitted evidence of SOVC issued by class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 August 2018 Resolved
Satisfactory means shall be provided for the protection of the crew. Repair wasted/ corroded guard rail and ladder identified at main ddeck starboard side at bay 21, and at ladder to satellite antenna on top of superstructure.Must fix prior to the next credit drydock.
Action required: 705 - Other - as specified
Resolved 5 October 2018
Resolution: Cleared via photos
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 11 August 2018 Resolved
The condition of the ship and its equipment shall be mainatined to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Door locks were found inoperable on decks A, B, C, D, and upper deck. Repair locks to the satisfaction of the Recognized Organization.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2018
Resolved 30 November 2018
Resolution: Cleared via class report. Attached.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 December 2017 Resolved
Ensure proper operation of the time delay release for the CO2 system covering the emergency generator room.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 4 January 2018
Resolution: Vessel provided a class report stating repairs have been completed to the EDG CO2 system.
Communications › Long Range Identification and Tracking (LRIT) › Software Package Update
Issued 13 June 2017 Resolved
Provide new LRIT conformance test report due to reflag into US registry IAW NVIC 01-13.
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 23 June 2017
Resolution: Received new conformance test report indicating proper system operation and new software update after reflag.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 June 2017 Resolved
Repair corroded or bent guard rails around the ship IAW ILLC 66/88 Reg 25.
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 10 July 2017
Resolution: ABS provided correction report.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 June 2017 Resolved
Renew HFO vent piping forward of the accommodation on port side cargo deck. ILLC 66/88 Reg 19.
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 10 July 2017
Resolution: ABS provided correction report.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 13 June 2017 Resolved
Repair doors with missing handles or key holes, one door is located in inner Bosn' store, one door is located on deck A cleaning gear locker. SOLAS II-2/reg9.
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 10 July 2017
Resolution: ABS provided correction report.
Deck/Cargo › Holds/Tanks › Hatch
Issued 13 June 2017 Resolved
Repair multiple cargo hold vent covers with corroded, bent or missing latching mechanisms. SOLAS II-2/reg 14.
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 10 July 2017
Resolution: ABS provided correction report.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 June 2017 Resolved
Replace fire control plan symbol near the accommodation entrance, p/s, with approved IMO fire control plan symbols. SOLAS II-2/Reg 15
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 10 July 2017
Resolution: ABS provided correction report.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 June 2017 Resolved
Repair non-functioning emergency lights and exit lights found during blackout test: Emg-lights: Outside chief engineer's stateroom and Deck E main stairway. Exit-Lights: Port side poop deck, Deck D SOLAS II-2/Reg 13
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 10 July 2017
Resolution: ABS provided correction report.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 June 2017 Resolved
Place IMO placards/signs indicating whether a space is smoke detector protected or head detector protected space IAW approved fire control plan. SOLAS II-2/reg 15.
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 10 July 2017
Resolution: ABS provided correction report.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 June 2017 Resolved
Vessel is authorized an interim acceptance PUMS endorsement. Vessel has until the next scheduled dry dock to close all gaps not in accordance with USCG NVIC 01-13 enclosure (2) 3.2.1.
Action required: 705 - Other - as specified
Due 29 June 2019
Resolved 20 August 2019
Resolution: Verified remaining PUMS gaps as stated by vessel.

Ownership record