Records in 2020. Most recent: inspection, 9 November 2020.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2020
Resolved
07126 - MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCOS OBSERVED POOLED OIL UNDER THE MAIN ENGINE, ALL 3 GENERATORS, UNDER THE PURIFIER CONTROL PANEL, AND PURIFIERS. OIL LEAKS WERE OBSERVED THROUGHOUT THE ENGINE ROOM. ON THE MAIN ENGINE, ALL 3 GENERATORS, IN THE PURIFIER ROOM, ON THE FUEL OIL TRANSFER PIPELINES, NEAR THE AFTER PEAK TANK FROM DECK 3 TO THE BILGE, AND FROM THE OVERHEAD IN THE EDG ROOM. MULTIPLE BUCKETS AND RAGS WERE COLLECTING OIL LEAKS THROUGHOUT THE ENGINE ROOM.
74 SOLAS (04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 28 August 2020
Resolved
15108 - THE COMPANY SHOULD ENSURE ANY NON-CONFORMITY IS REPORTED WITH ITS POSSIBLE CAUSE, IF KNOWN. THE VESSEL FILLED OUT REQUIRED “PSC INSPECTION AND ROUTINE MAINTENANCE FOR MASTERS / CH. ENGINEERS” PRIOR TO ARRIVAL TO BALTIMORE CHECKING THAT THE OIL FILTERING EQUIPMENT AND EMERGENCY ESCAPE TRUNK SELF-CLOSING FIRE DOORS WERE “OK.”
74 SOLAS (14)IX/3
ISM Code 10.2.2
Condition: Invalid
Action required: 30 - Ship detained
Resolved 29 August 2020
Resolution: External audit to be carried out addressing this def.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 28 August 2020
Resolved
14104 - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION. VESSEL’S CREW FAILED TO PROPERLY OPERATE THE OILY WATER SEPARATOR.
MARPOL Annex I/6.4.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 August 2020
Resolved
07124 - ANNUAL INSPECTIONS SHOULD BE CARRIED OUT FOR THE FIXED GAS FIRE-EXTINGUISHING SYSTEMS, WATER MIST SYSTEMS, BREATHING APPARATUS AND PORTABLE FOAM APPLICATORS. THE LAST ANNUAL INSPECTIONS FOR THE LISTED EQUIPMENT WERE CONDUCTED IN APRIL 2019.
74 SOLAS (04)II-2/14.2.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 28 August 2020
Resolved
14501 - EVERY SHIP OF 100 GT AND UPWARDS SHALL CARRY A GARBAGE MANAGEMENT PLAN WHICH THE CREW SHALL FOLLOW. PER THE VESSEL’S GARBAGE MANAGEMENT PLAN, GARBAGE SHOULD BE STORED IN DESIGNATAED LOCATION (POOP DECK) IN SECURE CONTAINERS. PSCO OBSERVED LARGE QUANTITY OF GARBAGE IN PLASTIC BAGS STORED IN THE DECK COMPRESSOR ROOM.
MARPOL Annex V/10.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 August 2020
Resolved
07199 - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION. PSCO OBSERVED OIL LEAKING INTO EDG ROOM OVERHEAD. ADDITIONALLY, POOLED OIL WAS OBSERVED ON THE DECK OF THE “DECK COMPRESSOR ROOM “LOCATED DIRECTLY ABOVE THE EDG ROOM.
74 SOLAS (14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 August 2020
Resolved
07120 - MEANS OF ESCAPE FROM THE PROTECTED ENCLOSURE IN THE MACHINERY SPACE SHALL HAVE SELF-CLOSING FIRE DOORS. THE FIRE DOORS TO THE EMERGENCY ESCAPE ON THE BOTTOM DECK AND DECK 3 DO NOT LATCH CLOSED.
74 SOLAS (04) II-2/13.4.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2020
Resolved
11118 - A SUFFICIENT NUMBER OF LIFEJACKETS SHALL BE CARRIED FOR PERSONS ON WATCH. ONE LIFEJACKET WAS MISSING FROM THE ENGINE CONTROL ROOM.
74 SOLAS (14)III/7.2.4
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 August 2020
Resolved
02105 - HYDRAULIC POWER OPERATED STEERING GEAR SHALL BE PROVIDED WITH ARRANGEMENTS TO MAINTAIN THE CLEANLINESS OF THE HYDRAULIC FLUID. PSCO OBSERVED HYDRAULIC OIL POOLED AROUND AND UNDER THE STEERING GEAR.
74 SOLAS (14)II-1/29.12.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2020
Resolution: Received class report attesting to repairs.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 August 2020
Resolved
01315 - EACH COMPLETED PAGE OF THE OIL RECORD BOOK SHALL BE SIGNED BY THE MASTER. TWO COMPLETED PAGES OF THE OIL RECORED BOOK WERE NOT SIGNED BY THE MASTER.
MARPOL Annex I/17.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2020
Resolution: Received class report attesting to correction of ORB.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 28 August 2020
No resolution recorded
01107 - DUE TO THE ABOVE OBJECTIVE EVIDENCE THE CAPTAIN OF THE PORT QUESTIONS THE ADEQUACY OF THE IMPLEMENTATION OF THE VESSEL'S SAFETY MANAGEMENT SYSTEM. AN EXTERNAL AUDIT IS RECOMMENDED TO BE CONDUCTED WITHIN 30 DAYS BY THE FLAG STATE OR RECOGNIZED ORGANIZATION TO DETERMINE WHETHER THE SHIP IS OPERATING IN ACCORDANCE WITH THE ISM CODE.
74 SOLAS (14)IX/3.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days