Records from 2016 to 2020. Most recent: inspection, 25 August 2020.
Inspection history · 14
25 August 2020
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7038945
9 December 2019
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6869765
14 November 2019
Administrative Inspection · MTSA Verification · Deficiency Check · Periodic Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6854497
29 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6844291
9 September 2019
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6807600
3 April 2019
Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6655259
13 November 2018
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6579880
23 July 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6488211
20 June 2018
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6450304
6 February 2018
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6350188
15 September 2017
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6267068
16 May 2017
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6152085
17 March 2017
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6101563
18 October 2016
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6024757
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 November 2019
Resolved
A Class-1 door may be installed at any place if the vessel's pilothouse contains a visual indicator showing whether the door is open or closed. Indicator light does not change upon opening and closing of watertight door for the emergence escape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 26 November 2019
Resolution: Attended vessel and verified that indicator on bridge alarms when engine room door and espace hatch are opened.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 November 2019
Resolved
The following tests and inspections of fire-extinguishing equipment must be performed by the owner, operator, or master, or by a qualified servicing facility, to verify compliance with paragraph (a) of this section: All systems for detecting smoke and fire, including sensors and alarms, must be inspected and tested. Smoke detection system has not been inspected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 26 November 2019
Resolution: Verified record of latest fire detechtion inspection. Received updated procedures detailing the frequency, method and recording of testing fire detection system. Vessel procedures are attached in deficiency documents.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 November 2019
Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to provide services necessary for safety under normal and emergency conditions. Vessel's RADAR does not continue operation on emergency power.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 26 November 2019
Resolution: Attended vessel and verified that radar and port/starboard navigation lights operate on emergency power.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2018
Resolved
Engine room bulkhead penetration for PAM wireng not approved. provide plans for proper repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2019
Resolved 5 April 2019
Resolution: made penetration into engine room for PAMs watertight.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2018
Resolved
Metalic penetration for crane hydraulic drain line on engine room not proper. Provide plans for repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2019
Resolved 5 April 2019
Resolution: Installed approved piping to access the engine room from the hydraulic deck crane return line.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 4 October 2017
Resolved
Replace repair the following alarm sensors, PMDE HI OIL TEMP, SMDE HI OIL TEMP, STB R/G oil temp by 13OCT17
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 13 October 2017
Resolution: All 3 sensors were procured and installed, company provided certs for each and attested install. cleared 835 item.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 15 September 2017
Resolved
conduct PSTP IAW approved procedures.
Action required: 705 - Other - as specified
Due 9 October 2017
Resolved 4 October 2017
Resolution: test conducted
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 September 2017
Resolved
Repack through bulkhead penetrations in eng room by 13OCT17
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 13 October 2017
Resolution: All through bulkhead penetrations were sealed with fire retardant penetrate, cleared 835.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 15 September 2017
Resolved
Prove proper operations on alarm panel, during lamp test banks for #2 Generator and #1 MDE failed to light during test. Repair by 13OCT17.
Action required: 705 - Other - as specified
Due 1 January 2018
Resolved 11 January 2018
Resolution: Tech Reps from Gulf Coast visit repair actions. RCV letter from Tech's stating they rewrote the program to correct failed test lighting. Tested panel "Alarm Test" conducted and local test of HI bilge lifted, tests SAT.