Records from 2016 to 2026. Most recent: inspection, 6 February 2026.
Inspection history · 23
6 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8307056
23 September 2025
PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8239961
18 December 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8049021
6 July 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7734454
20 March 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7670363
6 December 2022
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7605194
16 January 2022
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7387497
21 December 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7347724
8 November 2021
Excursion Permit
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7344199
27 January 2021
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7132044
3 November 2020
Drydock Extension · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7088568
28 September 2020
MARPOL Annex IV Survey · COI Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · Deficiency Check · Drydock Extension
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7065126
25 September 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7072048
6 August 2020
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7023846
14 January 2020
Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6889248
10 December 2019
Annual Inspection · Plan Review (Other than "T") · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6850243
16 October 2018
Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Periodic Inspection · MARPOL Annex V Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6562138
28 September 2018
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6550700
22 December 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6327829
1 November 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6301536
12 December 2016
Deficiency Check · MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification · MARPOL Annex VI Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6056235
8 December 2016
Examination of Repairs · Construction Oversight · Damage Survey · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6054880
15 January 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5798382
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 23 September 2025
Resolved
For any vessel that is equipped with ballast water tanks bound for ports or places in the US...Submit the ballast water report no later than 6 hours after arrival. Master did not submit ballast water report within 6 hours of arriving to port.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 September 2025
Resolved 24 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2023
Resolved
Each generator arranged for parallel operation must have reverse-power. Reverse-power was not able to be done due to generator not being reset by 3rd party tech. Provide tech report for completion of reverse-power.
46 CFR 111.12-11(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 6 July 2023
Resolution: Generator override corrected by CAT tech.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 21 December 2021
Resolved
For each ship subject to regulations 5 and 6 of this Annex, details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of a bunker delivery note which shall contain at least the information specified in appendix V to this Annex. The bunker delivery note shall be kept on board the ship in such a place as to be readily available for inspection at all reasonable times. It shall be retained for a period of three years after the fuel oil has been delivered on board. The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered taking into account guidelines developed by the Organization. The sample is to be sealed and signed by the supplier’s representative and the master or officer in charge of the bunker operation on completion of bunkering operations and retained under the ship’s control until the fuel oil is substantially consumed, but in any case for a period of not less than 12 months from the time of delivery. At the time of inspection vessel did not have bunker delivery notes or fuel samples on board for inspection. Provide bunker delivery notes and fuel samples for next bunkering and provide corrective actions to ensure compliance with fuel quality requirements. - MARPOL Annex VI, Reg 18
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 22 December 2021
Resolution: Vessel received bunkers 22DEC2021 and obtained bunker delivery note and sample.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 21 December 2021
Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications. (b) Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Vessel failed to complete annual periodic safety tests. Emergency generator engine overspeed, jacket water high temperature and low lube oil tests were not conducted. Complete PSTPs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 22 December 2021
Resolution: Vessel completed PSTPs.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 December 2021
Resolved
Each emergency switchboard must have the following: (1) An ammeter with a selector switch that connects the ammeter to show the current for each phase. Emergency generator switchboard ammeter inoperable. Demonstrate proper operation of ammeter.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 16 January 2022
Resolution: Vessel provided objective evidence showing working ammeter.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 6 November 2020
Resolved
The safety managment system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention.
The vessel Safety Management System Manual, Revision 21, Section 9.0 requires that all PR-17s and 835s issued to the vessel shall have a work order submitted through Preventer, and requires management to review all report of non-conformaties and implement correct actions.
Following CG-835s issued during COI inspection on 28SEP2020, no work orders were submitted via "Preventer," and no records were available regarding management review. CG-835s were not resolved by the due date of 28OCT2020.
Complete internal safety audit and provide corrective action prior to 06FEB2021.
SOLAS 74a IX/3.1
ISM 9.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2021
Resolved 27 January 2021
Resolution: Vessel completed internal audit and provided report and corrective actions.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 November 2020
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provision of the relevant regulations and rules and with any additional requirements which may be established by the company.
The Vessel Safety Systems Manual, Revision 21, Section 10.3 states that proceudres for maintenance and inspection are contained in the SIP manual, and that the vessel maintenance software (Preventer) contains the step by step instructions required to complete the above referenced critical equipment preventative maintenance. On board Preventer system did not conatain tasks for calibration of the oil content meter, rescue boat davit tests and servicing of release mechanism. Periodic safety test prcedure completion was a task which was not completed.
Complete internal safety audit and corrective action plan prior to 06FEB2021.
SOLAS 74a IX/3.1
ISM 10.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2021
Resolved 27 January 2021
Resolution: Vessel completed internal audit and provided report and corrective actions.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 6 November 2020
Resolved
Each company should develop, implement and maintain a safety management system which includes instruction and procedures to ensure safe operation of ships and protection of the envireonment in compliance with relevant international and flag state legislation.
Vessel Health Safety Environmental Continuous Improvement Manual (HSE CIM), Chapter 29, states inspections by ABS ad the USCG will be coordinated by the vessel manager, and that all documentation will be filed accordingly. Vessel amster has coordinated inspections of vessel. Notice of COI inspection request was made less than one week prior.
Complete internal safety audit and provide corrective action plan prior to 06FEB2021.
SOLAS 74a IX/3.1
ISM 1.4.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2021
Resolved 27 January 2021
Resolution: Vessel completed internal audit and provided report and corrective actions.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 6 November 2020
Resolved
The company should establish procedures to ensure that personnel transferred to new assignments related to safety and protection of the environment are given proper familiarization with their duties.
The HSE CIM, Chapter 30, states that the Chief Engineer shall prepare a handover log prior to being relieved from the vessel. The report shall remain on board until all listed deficiencies from ABS, USCG adn the vessel manager are corrected. No handover log was created for Chief Engineer relief on 01OCT2020, and five USCG deficiencies were outstanding.
Complete internal safety audit and provide corrctive action plan prior to 06FEB2021.
SOLAS 74a IX/3.1
ISM 6.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2021
Resolved 27 January 2021
Resolution: Vessel completed internal audit and provided report and corrective actions.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 28 September 2020
Resolved
Operational tests and overhaul is required for rescue boat release mechanisms at five-year intervals. Provide testing and overhaul report. - SOLAS 74a III/20, MSC 96/25
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 6 November 2020
Resolution: Vessel procured and installed replacement CAR 35 off load relaese hook. Off load relaese function was tested in presence of marine inspector after installation.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 28 September 2020
Resolved
The accuracy of bilge alarms must be checked at IOPP renewal surveys. Provide calibration report for bilge alarm (oil content meter).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 6 November 2020
Resolution: Technician attended 05NOV2020 and conducted calibration. Report was provided to marine inspectors on 06NOV2020.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 28 September 2020
Resolved
Periodic testing procedures (PSTPs) describe mechanical/manual testing of machinery. Vessel is equipped with electronically controlled engines and was not able to demonstrate tests. Provide revised PSTPs and/or demonstrate tests of machinery safeties. 46CFR130.480/46CFR62.20-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 6 November 2020
Resolution: PSTPs were conducted in presence of marine inspector on 06NOV2020. Attending Caterpillar technician and vessel chief engineer conducted tests.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 September 2020
Resolved
Latches for the CO2 fixed fire fighting system control boxes on main deck were found seized. Replace latches.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 6 November 2020
Resolution: Vessel replaced latches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2020
Resolved
Port air receiver pressure release valve did not relieve at designed pressure. Replace and demonstrate proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 6 November 2020
Resolution: Vessel procured and installed replacement relief valve. Valve was tested satisfactorily in presence of attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 September 2020
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valves that are arranged to have remote control. Shutoff valve on port generator day tank not functioning.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 September 2020
Resolved 28 September 2020
Resolution: Vessel dissassembled and rebuilt valve, then demonstrated operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2018
Resolved
The relief valve for the port air receiver is not operating. Repair or replace relief valve and prove proper operation of the same.
Action required: 10 - Deficiency Rectified
Due 12 December 2019
Resolved 12 December 2018
Resolution: Deficiency found and corrected during inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 December 2018
Resolved
All QAWTD's and the Engine Room emergency escape QAWTH were not sealing properly. Adjust all QAWTD's and hatches to make watertight.
Action required: 10 - Deficiency Rectified
Due 14 December 2018
Resolved 12 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 December 2018
Resolved
Found all lifebuoy floatlight batteries expired. Replace all floatlight batteries.
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 December 2018
Resolved
Found the emergency generator not assuming the load within the required 45 seconds. Make adjustments and prove proper operation of the emergency generator.
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 12 December 2018
Resolved
Compass not mounted correctly.(missing screws)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
Resolution: Missing screws replaced
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 12 December 2018
Resolved
Retroflective tape missing from the bottom of the rescue boat, The boat is not sel righting.
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
Resolution: Retro placed on bottom of the boat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 12 December 2018
Resolved
Search light in rescue boat did not work.
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
Resolution: Battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 12 December 2018
Resolved
Flashlight missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
Resolution: Flashlight with sparebatteries place in bag for rescue boat.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 12 December 2018
Resolved
Fire team attemted to attack a fire inside without SCBA's. half the crew stated they did not us the SCBA's to fight fires they were just for rescue.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
Resolution: Met with Master, vessel representive and Safety Officer. Crew trained and drill redone satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 December 2018
Resolved
3 exterior emergency lights did not operate.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
Resolution: E-lights replaced and tested.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 December 2018
Resolved
Rupture disk ruptured in 1 of the mud tank vents.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2018
Resolved 12 December 2018
Resolution: Rupture disk replaced.
Documentation › Logs/Records › Oil Record Book
Issued 1 November 2017
Resolved
Improper documentation of the ORB
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 22 December 2017
Resolution: Witnessed proper logging in ORB.
Fire Fighting › Fire Pumps › Pressure
Issued 1 November 2017
Resolved
Main and emergency fire pump gage on the bridge not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 22 December 2017
Resolution: Witnessed proper operation of fire pump gauges on bridge.
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 1 November 2017
Resolved
Tech files for the mains and the generators not onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 4 December 2017
Resolution: Tech files onboard.
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 1 November 2017
Resolved
Parts changes and maintenance in engineering not properly documented in tech files.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 4 December 2017
Resolution: Parts and maintenance properly documented on Tech files.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 1 November 2017
Resolved
Recommending internal audit of the ISM system to be conducted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 22 December 2017