MAURY USCG vessel records
← All vessels

GEORGE III

GEORGE III is a 2022 freight ship. The Coast Guard has recorded 36 inspections since 2018, most recently in March 2026, along with 34 deficiencies — 1 with no resolution recorded —, 3 operational controls and 2 casualty investigations between 2021 and 2024.

Records from 2018 to 2026. Most recent: inspection, 14 March 2026.

Built
2022
Last inspected
14 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9837092
WDK4356
1486054
Flag
UNITED STATES
Maury page id
psix-1486054

Inspections, by type

…with no type recorded3
Years with a record 8 calendar years (2018–2026)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)725.8 ft × 114.8 ft × 57.0 ft
Registered tonnagegross 45,397 / net 34,725
ITC dimensions (L × B × D)725.8 ft × 114.8 ft × 57.0 ft
ITC tonnagegross 45,645 / net 16,599
BuilderKEPPEL AMFELS INC · BROWNSVILLE, TX, UNITED STATES · built 2022
Hull materialSteel
PropulsionDual Fuel (Diesel & Liquefied
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45645 - Convention (Subpart B), Gross Ton
45397 - Regulatory (Subpart C or D), Gross Ton
16599 - Convention (Subpart B), Net Ton
34725 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 36

14 March 2026 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8327533
12 March 2026 Bulk Liquid Transfer Monitor
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8325476
5 March 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8320482
29 October 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8261258
14 October 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8251967
23 September 2025 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8239744
8 May 2025 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8131278
22 January 2025 ISM Oversight · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8072490
6 December 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8044003
4 December 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8044377
23 November 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8038926
8 November 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8026072
27 October 2024 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8025171
25 October 2024 ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8025834
24 October 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8025836
23 October 2024 Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8024032
20 September 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8006583
3 August 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7973316
1 August 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7975717
25 June 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7944126
22 June 2024 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7939894
28 January 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7898419
26 October 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7815111
18 August 2023 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7751124
15 February 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7637149
17 August 2022 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7535706
27 July 2022 COI Inspection · ACP Handover Survey · Initial Certification
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7518213
19 July 2022 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7511219
1 October 2021 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7343182
23 October 2019 Construction Oversight · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6840582
19 December 2018 Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6600654
30 November 2018 Construction Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6596518
5 October 2018 Construction Oversight · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6564677
27 September 2018 Construction Oversight
Physical examination · Activities Europe · Activity 6549696
25 September 2018 Construction Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6547905
9 February 2018 Inclining Experiment · Construction Oversight
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6352749

Deficiency record · 34

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 22 January 2025 Resolved
The company should periodically evaluate the effectiveness of the safety management system in accordance with procedures established by the company. The audits and corrective actions should be carried out in accordance with documented procedures. On 24OCT2024 the vessel was issued a requirement to conduct an internal audit focused on the maintenance of the steering system. The provided audit did not follow established company procedures and did not contain objective evidence of an appropriately conducted or focused audit. Company shall arrange for an external vessel audit with a minimum scope to include this deficiency, the deficiency issued on 24OCT2024, and relevant aspects of the ISM Code. 74 SOLAS (20) IX/3.1 ISM Code 12.4
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2025
Resolved 28 February 2025
Resolution: External SMC audit conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2024 Resolved
Hazardous areas on open decks and other spaces not addressed in this chapter shall be decided based on a recognized standard. The electrical equipment fitted within hazardous areas shall be according to the same standard. MI identified 06 deck lighting fixtures in the vicinity of the fuel storage tanks that appear to have been shorted out and are not operational. Repair and replace the lighting fixtures. IGF Code 12.3.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2024
Resolved 26 November 2024
Resolution: Deficiency accepted by RO as a finding w/ due date of 23DEC2024.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. Vessel does not have on board testing equipment for heat detectors located in hazardous locations. 74 SOLAS (20) II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2024
Resolved 26 November 2024
Resolution: Deficiency accepted by RO as a finding. Associated testing equipment has been ordered and should arrive in 45 days. RO finding has a due date of 06Jan2025.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 8 November 2024 Resolved
The machinery, associated piping systems and fittings shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces and other hazards. Replace section of insulation for fuel supply piping to main engine. 74SOLAS(20) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2024
Resolved 26 November 2024
Resolution: Deficiency accepted by RO as a finding w/ due date of 23DEC2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2024 Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessel's LT cooling water three-way valves for all 03 generators are leaking. 74 SOLAS (20) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2024
Resolved 26 November 2024
Resolution: Deficiency accepted by RO as a finding w/ due date of 23DEC2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2024 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Pilot reported the rudder jammed hard over to port during berthing process. 74 SOLAS(20) I/11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 November 2024
Resolved 27 October 2024
Resolution: Received ABS Class Report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 October 2024 Resolved
Scuppers and discharge pipes originating at any level and penetrating the shell either more than 450 mm below the freeboard deck or less than 600 mm above the Summer Load Line shall be provided with a non-return valve at the shell. MI observed leaking aft scupper (MSD overboard) valve with soft patch and clamps. ICLL (88) Annex 1 22
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 25 October 2024
Resolved 27 October 2024
Resolution: Class accepted deficiency and extended compliance date.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 October 2024 Resolved
Additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. MI observed escape signage blocked in port tunnel at frame 41 outside of machine shop. 74 SOLAS (20) II-2/13.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 October 2024 Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class division. MI observed self closing door to escape trunk in ECR, as identified on Fire Control Plan, unable to automatically close. 74 SOLAS (20) II-2/15.2.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Accepted by RO.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 October 2024 Resolved
Each survival craft shall be stowed: in a state of continuous readiness so that two crew members can carry out preparations for embarkation and launching in less than 5 min. MI observed removable chain outboard of part and starboard life rafts seized preventing crew from ability to quickly deploy. 74 SOLAS (20) III/13.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Accepted by RO.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 October 2024 Resolved
Maintenance... and inspections shall be carried out based on the guidelines developed by the Organization. Multi-cable transit at AC room found improperly sealed. 74 SOLAS (20) II-1/14.2.2.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Accepted by RO.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 October 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. MI observed 4'' fracture inboard aft foot of natural vent pipe on mooring deck. 74 SOLAS (20) I/11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2024
Resolved 8 November 2024
Resolution: Accepted by RO.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 October 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Containment in aft most corner of purifier room IVO fuel tank kick valve found leaking diesel. 74 SOLAS (20) I/11
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2024
Resolved 8 November 2024
Resolution: Accepted by RO.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 October 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date, except as required in paragraph (b) of this section. Vessels annual inspection was conducted without the oversight of a properly qualified machinery inspector holding the low flashpoint fuel qualification. Vessel shall make the vessel available to complete the required inspection. 46 CFR 91.27-1(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Vessel completed remaining inspection items at Sector LA/LB with LFF Machinery inspector.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2024 Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. No. 1 hydraulic reservoir tank is fractured and leaking at the return line. 74 SOLAS (20) II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 8 November 2024
Resolution: Accepted and corrected to the satisfaction of RO.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 October 2024 Resolved
All the steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the Administration. No. 2 steering gear pump oil cooler inlet line soft patched and leaking. 74 SOLAS (20) II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 8 November 2024
Resolution: Accepted and extended by RO.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 24 October 2024 Resolved
...No person may cause a vessel to enter into or get underway on the navigable waters of the United States unless no more than 12 hours before entering or getting underway, the following equipment has been tested: Each rudder angle indicator in relation to the actual position of the rudder. Provide photographs of pre departure test logs for departure from Port of Oakland on 23OCT2024. 33 CFR 164.25(a)(1)(iv)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 8 November 2024
Resolution: Reviewed photographs and log entries of vessel's steering and rudder angle indicator testing during inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 24 October 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Vessels steering system and rudder angle indicators were found to be malfunctioning. Review of ships documentation indicate that the equipment had not been operating properly in the five months preceding the inspection and had yet to be rectified or had the root cause accurately identified. Inspections of the equipment further identified two additional deficiencies including a fracture on the hydraulic reservoir of the #1 steering pump. Company shall conduct an internal audit focused on the maintenance of the steering system and all of its associated components. 74 SOLAS (20) IX/3.1 ISM CODE 10.2
Action required: 705 - Other - as specified
Due 22 January 2025
Resolved 18 February 2025
Resolution: Extended compliance deadline at the request of the company. Cleared for non-acceptance of provided audit and re-issuance of new requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 October 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea and without danger to the ship or persons onboard. Vessel reported 15 degree discrepancies between the command given at the help and the rudder angle indicator. Provide report attesting to the repair and proper operation of the steering and rudder angle indicator. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 23 October 2024
Resolved 27 October 2024
Resolution: Corrected to the satisfaction of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
Smoke detectors alone shall not be considered sufficient for rapid detection of a fire. Flame detectors for bunker stations and rooms of fuel gas system inoperable. Vessel to submit a risk assessment for continued operations and repair plan. IGF 2016 / 11.7.2
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2023
Resolved 18 August 2023
Resolution: Vessel submited risk anaylsis and acceptable mitigating procedures.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 18 August 2023 Resolved
The certificates and records of equipment shall be drawn up in the form corresponding to the models given. Cargo Ship Safety Construction Certificate does not properly endorse the vessel to operate with LNG as a fuel and does not document associated Alternative Designs approved by administration IAW SOLAS 20 II-1 / 55. 74 SOLAS (Consl 20) I / 15
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 1 September 2023
Resolved 13 October 2023
Resolution: ABS issued correct certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
Prior to conducting bunkering operations, pre-bunkering verification shall be carried out and documented in the bunker safety checklist to include: Operation of fire detection equipment. Vessel does not currently have a means to test flame detectors and it is not included in pre-bunker safety checklist. IGF 2016 / 18.4.3
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 13 October 2023
Resolution: Vessel added magentic function test to procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
Tank High and Overfill alarms shall be tested prior to fuel operation in accordance with 18.4.3 (Pre-bunker procedures). Vessel did not test high/overfill alarms prior to bunkering and it is not included in the Pre-bunker safety checklist.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 13 October 2023
Resolution: Vessel added High/Overfill checks to DOI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
A risk assessment shall be conducted to ensure that risks arising from the use of low-flashpoint fuels affecting persons on board, the environment, the structural. Approved risk assessment requires the opposite bunker station to be monitored. Vessel did not have CCTV monitored during bunkering ops and it is not included in bunkering procedures. IGF 2016/4.2 Risk Assessment #35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 13 October 2023
Resolution: Procedures updated to provide full time monitoring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 August 2023 Resolved
A fuel system schematic/piping and instrumentation diagram (P&ID) shall be reproduced and permanently mounted in the ship's bunker control station and at the bunker station. Ship does not have a P&ID located at the bunkering station. IGF 2016 / 18.4.2.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 13 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 August 2023 Resolved
The bunkering manifold shall be designed to withstand external loads during bunkering. Saddle to support Bunker line is too low and requires crew to utilize wood blocks and strap downs to secure it. IGF 2016 / 8.4.1
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 13 October 2023
Resolution: vessel built saddle to use on low saddle and uses crane with support holster to keep hose secure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
Equipment installed in hazardous areas shall be minimized to that required for operational purposes and shall be suitably and appropriately certified. Vessel is utilizing a chain fall for bunkering that is not certified for hazardous spaces. IGF 2016 / 3.2.5
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 1 September 2023
Resolved 28 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
All pipelines or components which may be isolated in a liquid full condition shall be provided with relief valves. Identified areas on HP return and LNG fuel supply lines from tanks with two valves in series and no relief valve. IGF 2016 / 7.3.1.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 28 January 2024
Resolution: Valves currently locked in open position, vessel to make pernament modifications at next DD or Tank Inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
The setting of the PRV's shall not be set higher than the vapor pressure that has been used in the design of the tank. Vessel unable to provide calibration/manfacturer certification for Tank PRV setting (MARVS). IGF 2016 / 6.7.2.4
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2023
Resolved 28 January 2024
Resolution: Received and uploaded PRV certificates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
The arrangement and installation of fuel piping shall provide the necessary flexibility to maintain the integrity of the piping system. Support bracket for PRV on high pressure skid found broken on a system that has had a previous failure. IGF 2016 / 7.3.5
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2023
Resolved 13 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 No resolution recorded
Each liquefied gas fuel tank shall be fitted with a high level alarm. STBD tank high level alarm is mislabeled when activated as a 98% overfill alarm. IGF 2016 / 15.4.2.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2023 Resolved
An audible and visual alarm system to give warning on both sides of the airlock shall be provided to indicate if more than one door is moved from the closed position. MI's found alarms for airlocks disabled. IGF 2016 / 5.12.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 August 2023
Resolved 18 August 2023
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 25 May 2021 Resolved
Multiple atex items have been and multiple items have been identified by ADMINISTRATION that have not been taken for action
Action required: 703 - Prior to bunkering operations
Resolved 28 July 2022
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 29 April 2021 Resolved
IGF CODE 5.10 REGULATIONS FOR DRIP TREYS. DRIP TREY DO NOT MEET 5.10.1/5.10.4. multiple drip trey utilaze a cascade system to capture LNG and run to piping wit ha valve and flange arangement with n otrey under to protect carbon steel.
Condition: Design Flaw
Action required: 703 - Prior to bunkering operations
Resolved 28 July 2022
Resolution: prior to cool down

Casualty record · 2

1 October 2021Routine · role: Involved in a Marine Casualty · activity 7343182
24 October 2024Routine · role: Involved in a Marine Casualty · activity 8025836
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.