MAURY USCG vessel records
← All vessels

DLB SUPER CHIEF

Built
1999
Last inspected
4 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 June 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK8406
492193
Flag
UNITED STATES
Maury page id
psix-492193

Documentation record

Registered dimensions (L × B × D)240.0 ft × 72.0 ft × 16.0 ft
Registered tonnagegross 2,559 / net 767
ITC dimensions (L × B × D)240.0 ft × 72.0 ft × 16.0 ft
ITC tonnagegross 2,559 / net 767
BuilderCORN ISLAND SHIPYARD INC · GRANDVIEW, IN, UNITED STATES · built 1999
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itIndustrial Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2559 - Convention (Subpart B), Gross Ton
767 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

4 June 2026 Administrative Inspection · Damage Survey · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8391335
28 July 2025 Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8196344
1 April 2025 Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8103587
1 August 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7972331
7 August 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7762587
19 April 2022 COI Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7434099
21 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7012265
19 March 2020 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6928875
31 January 2020 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6901988
14 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6683672
12 July 2018 Administrative Inspection · Deficiency Check · Annual Inspection · Commercial Dive Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6477112
16 March 2017 Administrative Inspection · COI Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam · Commercial Dive Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6106607
25 July 2016 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5952957

Deficiency record · 48

09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 4 June 2026 Resolved
Water heaters electrically heated with capacity of less than 120 gallons, with heat input less that 200,000 BTU's per hour, must be listed by Underwriters Laboratories (UL) under UL 174 or UL 1453, and be protected by a preseason-temperature relief device. One (01) water heater on the O2 deck suffered from a fire in a maintenance cabinet caused by a shorted heating element. Vessel must provide repair proposal or replace in kind, and provide proof remaining water heater meets above requirements prior to departure. 46 CFR 53.01-10(c)(1)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2026
Resolution: Inspected sat installation of water heaters.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 28 July 2025 Resolved
MSD Sewage tanks must be free of defects that would allow toxic substances to escape to the interior of the vessel. MSD sewage tank top was wasted and the forward corner was open to the space.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2025
Resolution: New top installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 July 2025 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked. The entrance to the CO2 storage space was missing the required marking. 46 CFR 97.37–11
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2025
Resolution: Verified signs posted.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 28 July 2025 Resolved
General arrangement plans shall show, for each deck, the location of fire extinguishing appliances. The fire extinguisher indicated on the fire control plan for the dive control station was found missing from its enclosure and 1 not serviced.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2025
Resolution: Fire extinguishers replaced
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 July 2025 Resolved
Flexible connections between CO2 cylinders and distribution piping shall be re-tested when the cylinders are tested. CO2 Cylinders were tested 2025, no recent test conducted on flexible connections installed 6/2017.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2025
Resolution: Hoses replaced.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 28 July 2025 Resolved
A ship 300 gross tons or more must have an enclosed deck area around each bulk lube oil tank. The coaming on the upper deck port side (where the two hydraulic oil tote tanks are stored) is wasted and needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2025
Resolved 30 July 2025
Resolution: Containment repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2025 Resolved
At least two lifebuoys, each with attached self-activating smoke signals, must be stowed where they can be quickly released from the navigating bridge and should, when released, fall directly into the water without striking any part of the vessel. Vessel did not have the bridge buoys properly mounted to free fall; remount buoys in the proper location.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2025
Resolved 24 July 2026
Resolution: Brackets are on order est del 4-6 weeks. Verified during JUL2026 annual.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2025 Resolved
By October 1, 1999, fit retroreflective material on all floating appliances approved under approval series 164.018. Multiple life buoys did not have the proper retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2025
Resolved 30 July 2025
Resolution: Retro replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 July 2025 Resolved
The emergency loads must transfer to the final emergency power source in no more than 45 seconds after failure of the normal source of power. The emergency generator automatically started and started supplying power in one minute 32 seconds.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2025
Resolved 30 July 2025
Resolution: Verified the generator took load in 40 seconds.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2025 Resolved
The emergency lighting supplied by the final emergency power source must be sufficient to allow crew to find their way to open decks and to survival craft, muster stations, and embarkation stations with all watertight doors and fire doors closed. Multiple emergency lights were not working (PVHO, dive control room, second deck bow near fire station #20 and port side liferafts).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2025
Resolved 30 July 2025
Resolution: verified e-lighting.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 July 2025 Resolved
An inspection shall be made when any important alterations are undertaken. 12 CO2 bottles relocated from main deck to below deck. The installation was not IAW approved drawing or type approval manual. Both doors to the CO2 storage space opened inward. Not fitted w/ independent exhaust from bottom (6 air changes). Fire related boundaries not equivalent to control station A60 Submit proposal and plans to OCMI and MSC for approval.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2025
Resolved 24 July 2026
Resolution: Verified installation and testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 July 2025 Resolved
Nonmetallic flexible hose may be used in fuel oil system lengths not exceeding 30 inches. The #4 winch motor fuel supply hoses (before and after the Racor filter) exceeded 30 inches in length.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2025
Resolved 30 July 2025
Resolution: Filters moved allowing a shorter hose.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 July 2025 Resolved
Nothing shall limit the inspector from making such tests and inspections deemed necessary to be assured of the seaworthiness of the vessel. The fuel gauge (float gauge) for the emergency generator fuel tank was broken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2025
Resolved 31 July 2025
Resolution: Gauge replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 1 April 2025 Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by § 91.45-1. The general scope of the plans shall be as noted in § 91.55-5. Provide an updated fire control plan to include portable accommodation modules (PAMs) and all updates to fire-fighting and lifesaving equipment. Provide the installation plans for the lavatory/laundry PAM for approval by either ABS or USCG Marine Safety Center in accordance with CG-ENG Policy Letter 01-16. Provide PAM General Arrangement drawing to include dimensions, manufacturer, and serial number. PAM systems such as fire detection, general alarm, public address, and sanitary piping should be integrated to the host vessel systems.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 26 July 2026
Resolution: PAMS were on 2014 fire plan. Created CG# and added to COI.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 1 April 2025 Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by § 91.45-1. The general scope of the plans shall be as noted in § 91.55-5. Provide an updated fire control plan to include portable accommodation modules (PAMs) and all updates to fire-fighting and lifesaving equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2025
Resolved 4 November 2025
Resolution: Fire plans had the PAMS since 2014
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 5 August 2024 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Vessel had 02 SART's with expired batteries and missing emergency broadcast placard. Replaced expired batteries/SART's and add placard. 46 CFR 91.25-50
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2024
Resolved 6 August 2024
Resolution: Satisfactory documentation of renewed SARTS and broadcast placard were provided. See attached in deficiency documents tab.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 5 August 2024 Resolved
For vessels assigned a load line, see subchapter E (Load Lines) of this chapter, for special requirements as to strength, closure of openings, etc. Vessel's Load Line was not marked in accordance to the Load Line certificate issued. Correct in accordance to certificate at next Dry-Dock. 46 CFR 92.01-5
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 7 April 2025
Resolution: Vessel load line was repainted IAW Load Line cert.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 August 2024 Resolved
All vessels must have draft marks plainly and legibly visible upon the stem and upon the sternpost or rudderpost or at any place at the stern of the vessel as may be necessary for easy observation. Vessel's draft marks were not visibly painted. Make visible by next Dry-Dock. 46 CFR 97.40-10
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 7 April 2025
Resolution: Vessel's draft marks repainted.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 August 2024 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety of the vessel. EEBD in the 02-accommodation level was found empty. Breaker panel in accommodation PAM had a missing blank. 46 CFR 91.25-50
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 15 August 2024
Resolution: Photo evidence of correction provided by vessel rep to MI's.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 August 2024 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety of the vessel. Smoke detector on the 02-accommodation accommodation level was missing. The detector was reinstalled and tested satisfactorily. 46 CFR 91.25-50
Action required: 10 - Deficiency Rectified
Resolved 5 August 2024
Resolution: Crew reinstalled and tested satisfactoirly.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 August 2024 Resolved
In each crew berthing area and wash area, the owner or operator must display information in a visible location regarding sexual assault and sexual harassment, retaliation, and drug and alcohol usage and the procedures and resources to report crimes, including sexual assault and sexual harassment IAW 46 USC 11101 and CVC Policy Letter 23-04. Vessel had not yet equipped each these areas with the above information. - 46 USC 11101 CVC Policy Letter 23-04
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 7 August 2024
Resolution: Information regarding SASH was displayed in 19 staterooms, 16 Heads, and 5 common spaces.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 August 2024 Resolved
Owners and operators of applicable vessels must establish a master key control system and related provisions for use of master keys, and record keeping. Vessel does not currently have a master key control system. 46 USC 3106(a)(1) CVC Policy Letter 23-06
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 10 October 2024
Resolution: Vessel provided information of switching door hadnles to lockless and that all doors operate as intended.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 August 2023 Resolved
The boundary bulkheads and decks separating the accommodations from cargo and machinery spaces, galleys, main pantries and storerooms, other than small service lockers, shall be of “A” Class construction. Structural fire protection insulation missing on main deck overhead, underneath crew accommodations. Replace structural fire protection in accordance with approved plan.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 9 August 2023
Resolution: There is an air gap between compartment divisions and no documentation can be found identifying the division as A-60.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 August 2023 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. PAM M4B08KI2S180 installed on vessel's top deck at time of inspection. This PAM was not installed in accordance with CG-ENG PL 01-16. PAM may not be utilized on vessel until installed in accordance with CG-ENG PL 01-16.
Action required: 705 - Other - as specified
Due 8 August 2023
Resolved 27 November 2023
Resolution: PAM Removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 8 August 2023 Resolved
Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. Provide guards for rotating machinery on both fire pumps.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 9 August 2023
Resolution: Guards replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2023 Resolved
Inspector will determine that all fire-extinguishing equipment is in suitable condition. Portable CO2 extinguisher in emergency generator space had a wasted hose and no maintenance tag.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 9 August 2023
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2023 Resolved
The hydrants for exterior locations may substitute two 1 1/2 in outlets, each with a 1 1/2-in hose, supplied through a wye connection. Only one 1 1/2-in hose was provided at various exterior fire stations. Provide two hoses at each exterior fire station.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2023
Resolved 9 August 2023
Resolution: Hoses added.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 August 2023 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked. Properly label CO2 bottle storage space as well as entrances to spaces protected by CO2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 9 August 2023
Resolution: Space marked.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2023 Resolved
The branch line valves of all fire extinguishing systems shall be plainly and permanently marked. Label control valves in CO2 storage space to reflect drawing that is posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 9 August 2023
Resolution: System labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 August 2023 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Fuel hose chafed on generator. Replace hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 9 August 2023
Resolution: Hose replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 August 2023 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Batteries in emergency generator space were corroded and covered in acid. Repair/replace batteries to the satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 9 August 2023
Resolution: Battery installations cleaned.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 August 2023 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Fire pump motor electrical cable box was missing a grommet. Replace grommet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 9 August 2023
Resolution: Grommet replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 August 2023 Resolved
Each navigation light must meet the following: Meet the technical details of the applicable navigation rules. Anchor light inoperable. Repair/replace anchor light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 14 September 2023
Resolution: Light replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 August 2023 Resolved
Each device must be free of design defects that would allow toxic substances to escape to the interior of the vessel. MSD had multiple sewage leaks. Repair to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 9 August 2023
Resolution: MSD cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2023 Resolved
No repairs, replacements, or alterations shall be made to pressure vessels or their mountings without prior approval by the [name withheld] on pressure vessel were wasted. Provide repair proposal and effect repairs to the satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 9 August 2023
Resolution: Feet replaced.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 3 May 2022 Resolved
Barges with sleeping accommodations for more than six persons must display plans in accordance with their general arrangement. Vessel had missing firefighting and lifesaving items from general arrangement plan. Arrange firefighting and lifesaving items in accordance with the plan.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: Verified items on the fire and safety plan were in the locations described. All items were found in satisfactory location and condition.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 3 May 2022 Resolved
Marine Sanitation Device must be free of design defects that would allow toxic substances to escape into the interior of the vessel. Marine Safety Device tank top was leaking. Repair tank top.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: The Marine Sanitation Device was verified to be free of defects.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 May 2022 Resolved
The announcing station must be located adjacent to the general emergency alarm contact maker on the emergency bridge. Announcing system was not adjacent to the general alarm system. Make announcing system adjacent to the general alarm system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 5 May 2022
Resolution: The PA system was tested and found in satisfactory condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 May 2019 Resolved
Emergency stop of the emergency generator was inoperable. Replace or repair emergency pull stop.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 May 2019 Resolved
Fire boundary door leading to the galley had a mechanical stop installed to allow the door to be propped open. Remove mechanical stop to fire boundary protected space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2019 Resolved
OWS was inoperable at the time of inspection. Ensure OWS is operational and can preform function test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2019 Resolved
Identified 04 lifeings needing name and hailing port restenciled, and retroreflective material to be repalced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 May 2019
Resolved 14 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 May 2019 Resolved
Identified living quarter vent on port side accomodations deck that needed the weather tight gasket to be replaced. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2019 Resolved
Identified distribution panel on the main deck in vicinity of dive shack that was missing a handle to secure the panel door. Corrected on the spot.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 May 2019 Resolved
Identified several Emergency lights that were inoperable. Vsl is replacing lights with LED's.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2019 Resolved
Heat detector in the Galley space has paint on the sensor piece. Vsl to remove paint and ensure detector functions properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2018 Resolved
Numerous fans on main deck and engine spaces wired with extension cords. Fans should be wired with cable as per 111.60
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2018
Resolved 16 August 2018
Resolution: All wiring ran with marine cable as per 111.60.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 July 2018 Resolved
Provide a dive supervisor, conduct diving gear inspection as per applicable parts of 46 CFR 197. This is to be conducted prior to any dive operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2018
Resolution: Dive checklist completed

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.