Inspection history · 20
29 April 2026
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8343660
6 April 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8343654
3 June 2025
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8150226
28 May 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7922082
21 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7882742
24 April 2023
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7673083
7 June 2022
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7470699
24 May 2022
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7457609
24 February 2022
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7401009
3 June 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7214115
12 August 2020
Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 7031378
18 May 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6955165
11 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6924884
17 June 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6716622
19 April 2018
Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6395135
5 March 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6365806
2 June 2017
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6163717
28 June 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5922939
7 April 2016
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5853174
12 January 2016
Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5795969
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 April 2026
Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. Vessel has missed their drydock deadline of 26FEB2026. Vessel is restricted from carrying passengers until drydock credit is given.
46 CFR 176.100(b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2026
Resolution: Completed credit drydock.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 28 May 2024
Resolved
Vessels must carry at least 3 red hand flares approved in accordance with 46 CFR 160.021 and 3 hand orange smoke distress signals in accordance with 46 CFR 160.037. Vessel's orange hand smoke signals were expired. Replace all expired pyrotechnic signals with new distress signals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 May 2024
Resolution: received satisfactory evidence that flares have been replaced with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2024
Resolved
At least one ring life buoy must be fitted with a lifeline of at least 60 feet in length which must be attached around the body of the ring life buoy. Ring buoy lifeline was attached to buoy grab lines. Remove lifeline from buoy grab lines and attach line to body of buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 5 June 2024
Resolution: Received satisfactory evidence (photos) for the vessel's water light lanyard of at least 3 ft in length and vessel's lifeline around the body of ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2024
Resolved
Each ring life buoy with a floating water light must have a lanyard of at least 3 feet but not more than 6 feet in length securing the water light around the body of the ring life buoy. Water light was found to be of insufficient length. Replace and attach appropriate length line to water light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 5 June 2024
Resolution: Received satisfactory evidence (photos) for the vessel's water light lanyard of at least 3 ft in length and vessel's lifeline around the body of ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 21 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Vessel lacks longitudinal structural members. Thus, the wood planking that rests on top of the pontoons sags in between the lateral supports. Vessel needs additional longitudinal supports of rigid construction - repair at next drydock. 46 CFR 177.100
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 29 April 2026
Resolution: MI did not see any additional sagging or softness in wood planking. Added a special note for point on interest at next inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
The metal framing just above the pontoons contained metal fasteners joining the wood beams to it. The metal around the fasteners was corroded, rendering the fastener & washers inefficient. Replacing the washers with a larger one will prove more coverage and support. Locations (from FWD to AFT):
PORT & STBD side at Compartments 1 & 2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 May 2024
Resolution: O/O provided photo evidence of repair (see Documents section).
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 21 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Vessel placed wooden (supportive) blocks in between the lateral metal framing to support sagging, wood planking. The wooden supports need to be permanently affixed/fastened to the base (i.e. wooden planking above the pontoons).
Locations (from FWD to AFT):
PORT side at Compartments 5 & 6
STBD side at Compartment 4
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 3 May 2024
Resolution: O/O provided photo evidence of repair (see Documents section).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Screws and washers drilled into base (i.e. wooden planking above the pontoons) were significantly corroded & require replacement.
Location (from FWD to AFT):
PORT side at FWD & AFT part of Compartment 4 (02 fasteners total)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 May 2024
Resolution: O/O provided photo evidence of repair (see Documents section).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
IAW a special note posted in 22APR2022, the pontoon plate thickness is 0.190". During today's inspection, pitting was found all throughout the upper half (unpainted portion) of the pontoons on both the PORT and STBD sides. All pits were measured to be no greater than 0.050" in depth. Covering the entirety of the pontoon with a protective paint/epoxy coating (to the satisfactory of the MI) is sufficient to reduce rate of pitting and spread; MI's should continue to monitor pitting & reassess at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 May 2024
Resolution: O/O provided photo evidence of repair (see Documents section).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2023
Resolved
Portable fire extinguisher installation and locaton must be to the satisfaction of the Officer in Charge, Marine Inspection. The brackets for the forward stbd side and aft port side portable fire extinguishers were not intended for use as fire extinguisher brackets. Replace brackets with maunfacturer type brackets.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2023
Resolved 15 May 2023
Resolution: Unit received documentation from vessel representative verifying installation of manufacturer type fire extinguisher brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2023
Resolved
Each item of lifesaving equipment determined by the marine inspetor to not be in serviceable condition must be repaired or replaced. Life ring was found to not be in serviceable condition at time of inspection. Repair or replace to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 15 May 2023
Resolution: Unit received documentation from vessel representative verifying replacement of life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Both port and starboard fuel supply lines were of diminished integrity due to exposure to the elements. Replace in accordance with manufacturer's requirements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 7 June 2022
Resolution: Damaged fuel line replaced w/appropriate hose & double clamped. Cleared via photo.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2022
Resolved
Portable and Semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. NFPA 10 chapter 6.1.3.6 states: Fire extinguishers installed under conditions where they are subject to dislodgement shall be installed in manufacturer’s strap-type brackets specifically designed for this problem. Current portable fire extinguisher brackets do not adequately protect the fire extinguishers from dislodgement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 7 June 2022
Resolution: Fire extinguishers secured from swinging on hanger via intalled straps. Cleared via photo.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 February 2022
Resolved
During the examination all accessible parts of the vessel's underwater body...shall be made available for examination. Multiple pits were identified during drydock inspection. Significant superficial material and growth were present on vsl's port and starboard pontoons as well as support beams. Thoroughly clean pontoons and support beams for re-inspection and be prepared to pressure test port and starboard pontoons.
Action required: 705 - Other - as specified
Resolved 22 April 2022
Resolution: Recieved letter attesting to the thickness of the pontoons .190" aluminum. All pitting is within policy.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 17 June 2019
Resolved
Master did not have required medical certificate issued with license.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2019
Resolved 15 July 2019
Resolution: Recieved email with picture of required medical certificate.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2019
Resolved
Close off sewage tank electrical switch to make watertight and remove dead end wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2019
Resolved 15 July 2019
Resolution: Recieved email with pictures of the capped off electrical switch and dead end wiring removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2019
Resolved
Retain copy of random drug testing results for 1 year.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 June 2019
Resolved 18 June 2019
Resolution: Corrected on the spot. O/O agreed to retain copies of random drug testing.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 August 2018
Resolved
Inspectors found a weak section of plywood deck at the embarkation point. Owner was instructed to make temporary repairs to the satisfaction of the attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2018
Resolved 30 August 2018
Resolution: The owner installed a piece of marine plywood over the soft sections of the deck. See attached photos.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 August 2018
Resolved
Vessel's port outboard engine was found not operational. Vessel must prove operation of all propulsion machinery prior to caring passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2018
Resolved 17 August 2018
Resolution: Owner took his vessel to a yard where it was repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 23 April 2018
Resolved
BS01. Replace recalled Kidde Fire Extiniguishers: 01 10:BC and 01 40:BC.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 3 May 2018
Resolution: The operator procured new fire extinguishers
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 April 2018
Resolved
BS02 Conduct and log drug and alcohol training.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 18 May 2018
Resolution: Master provided records of DAPI training
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 23 April 2018
Resolved
BS03 Provide MIS report data.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 3 May 2018
Resolution: The owner provided a copy of the 2017 MIS report as required.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 April 2018
Resolved
BS04 Provide training logs to Coast Guard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2018
Resolved 18 May 2018
Resolution: Master provided records of crew training
Documentation › Logs/Records › Logbook (official)
Issued 8 June 2017
Resolved
Provide log for 2017 drills, training and lifesaving equipment maintenance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 June 2017
Resolution: 21JUN2017: Received e-mail from [name withheld] regarding the vessel logbook and MIS Report.
EKO01: Provide log for 2017 drills, training and lifesaving equipment maintenance. 46CFR185.520
EKO02: Provide 2016 MIS report.
All deficiencies clear
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 8 June 2017
Resolved
Provide MIS report for year 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 19 June 2017
Resolution: 21JUN2017: Received e-mail from [name withheld] regarding the vessel logbook and MIS Report.
EKO01: Provide log for 2017 drills, training and lifesaving equipment maintenance. 46CFR185.520
EKO02: Provide 2016 MIS report.
All deficiencies clear
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 June 2016
Resolved
DC01: Replace port and starboard sidelight fixtures. 46 CFR 183.420. Due 29JUL16.
Action required: 705 - Other - as specified
Due 9 August 2016
Resolved 5 March 2017
Resolution: Witnessed test of new sidelights, all sat.