SAINT CHARLES

SAINT CHARLES is a 1951 freight ship. The Coast Guard has recorded 133 inspections since 1990, most recently in June 2022, along with 251 deficiencies and 8 casualty investigations between 2005 and 2011.

Records from 1990 to 2022. Most recent: inspection, 28 June 2022.

Built
1951
Last inspected
28 June 2022
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ6440
Flag
UNITED STATES
367138670, 367797780
Maury page id
psix-67883

Inspections, by type

…with no type recorded19
Years with a record 28 calendar years (1990–2022)
The 133 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)95.8 ft × 36.0 ft × 7.6 ft
Registered tonnagegross 233 / net 158
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAVONDALE MARINE WAYS, INC · AVONDALE LA, UNITED STATES · built 1951
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 July 2026 · expires 31 August 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it233 - Regulatory (Subpart C or D), Gross Ton
158 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD3966MMSI 367138670 · active · compulsorily equipped · granted 17 June 2026, expires 8 September 2036
WDJ6440MMSI 367797780 · active · compulsorily equipped · granted 30 June 2017, expires 30 June 2027
WDI4437MMSI 367698630 · expired · compulsorily equipped · granted 22 October 2015, cancelled 7 March 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 133

28 June 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7466144
10 June 2021 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7189819
14 May 2020 MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6953113
22 May 2019 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6690737
14 June 2017 Internal Structural Exam · Drydock Exam · Deadweight Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6173773
13 June 2012 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4342958
8 December 2011 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4198268
8 December 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4204491
19 September 2011 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4149495
19 September 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4150680
18 August 2011 COI Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4104422
7 July 2011 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4061502
25 February 2011 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3947319
2 December 2010 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3905462
15 September 2010 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3852856
2 March 2010 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3683820
21 December 2009 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3653667
15 December 2009 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3653645
12 December 2009 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3658858
8 December 2009 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3646349
27 July 2009 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3534547
2 May 2008 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3283399
2 May 2008 Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3302336
12 November 2007 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3126196
11 October 2007 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3124356
20 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3001870
18 July 2007 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3024209
8 May 2007 Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2925210
11 April 2007 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2905698
30 January 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2864161
7 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2867199
5 January 2007 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2852249
24 October 2006 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2812947
12 July 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2777594
11 July 2006 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2709330
8 March 2006 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2598389
4 January 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2590446
6 December 2005 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2547798
17 August 2005 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2513958
2 June 2005 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2387508
29 March 2005 MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2322239
9 March 2005 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2310584
23 February 2005 COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2297520
23 November 2004 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2250318
1 September 2004 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2220716
18 May 2004 Deficiency Check · Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2071360
26 February 2004 COI Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2013434
24 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978844
18 November 2003 Deficiency Check · Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1949789
19 August 2003 Quarterly Examination · Deficiency Check
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1880556
25 June 2003 Quarterly Examination · Deficiency Check
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1797370
13 March 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1767765
24 October 2002 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1694726
16 August 2002 Drydock Extension · Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1662219
22 May 2002 COI Inspection · Deficiency Check
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1619323
2 April 2002 Deficiency Check
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1600143
19 February 2002 Quarterly Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1487892
14 November 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410696
9 September 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 772451
22 August 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1423632
22 May 2001 Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1393689
10 May 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 124160
16 April 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062976
20 March 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1064588
21 February 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465619
4 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 92436
29 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 41283
28 August 2000 Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382016
19 June 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1053308
6 June 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 133837
23 May 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449318
14 April 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 70408
22 February 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1049666
1 December 1999 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812481
24 November 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433568
25 August 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460340
24 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1093774
14 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809431
3 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 805182
25 May 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1438836
20 April 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 132518
20 April 1999 Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442826
19 April 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1123749
2 March 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388741
23 December 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808107
1 December 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388656
2 September 1998 Deficiency Check · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427565
2 June 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472516
4 March 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1378291
4 December 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441320
30 October 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1450086
18 August 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383647
9 August 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 26183
14 July 1997 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1114214
30 June 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1112855
5 June 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380890
16 April 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1099402
5 March 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439838
26 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152500
8 February 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 87859
10 December 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404279
5 September 1996 Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446388
6 June 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360541
29 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1081916
11 April 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1080698
6 March 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385655
19 December 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380365
20 September 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434303
8 June 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435645
22 March 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355145
20 January 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 870024
20 December 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422455
15 September 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414361
16 June 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407338
21 December 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401794
23 September 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407199
22 June 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439414
9 March 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455054
30 December 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830237
21 October 1992 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426889
21 October 1992 Examination of Repairs · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469394
27 September 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259809
26 June 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266337
26 March 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263758
19 December 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1253883
26 September 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 935994
26 June 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232924
3 April 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232089
25 February 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917964
3 January 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241145
3 October 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924557
3 July 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906053
5 April 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216389

Deficiency record · 251

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 June 2022 Resolved
Periodic safety test must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Normally conducted annually. Engineer onboard did not conduct PSTPs throughout the year in accordance with the approved procedures. Conduct all PSTPs IAW approved procedures, log completion and retain log onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 12 August 2022
Resolution: PTSPs conducted and recorded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 June 2022 Resolved
The electrical installations shall be maintained in good electrical and mechanical condition to the satisfaction of the [name withheld] box covers missing for the flood lights that illuminate the FWD and AFT decks exposing outlets to weather. Repair outlet boxes returning them to weather-tight condition to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 12 August 2022
Resolution: Floodlight junction outlets had weather-proof covers installed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 28 June 2022 Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter for transferring - (a) To or from the vessel; and (b) From tank to tank within the vessel. Vessel could not provide transfer procedures for the transfer of oily bilge residues to and from vessels into the 18,000 gallon tanks on deck. Provide procedures that meet the requirements of 33CFR part 156.
Action required: 703 - Prior to bunkering operations
Due 12 July 2022
Resolved 12 August 2022
Resolution: Transfer procedures created and stored onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2022 Resolved
Each Lifebuoy stowage must be marked with the words “LIFEBUOY” or “LIFE BUOY” or with the appropriate symbol from IMO resolution A.760(18). Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port. There were no markings for any of the Lifebuoy stowage location and the lifebuoy mounted on the port aft bulkhead of the superstructure had no markings indicating the name of the vessel or the port. Label stowage locations and lifebuoys to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 12 August 2022
Resolution: Labeling provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 June 2022 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The request for inspection was submitted with less than 30 days before the due date (required by 46 CFR 91.25-5). This annual inspection began after the 3 month window from the anniversary date and is not completed due to the number and severity of outstanding deficiencies. Correct the outstanding deficiencies in order to complete the annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2022
Resolved 12 August 2022
Resolution: Inspection completed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 June 2022 Resolved
Hose used to transfer oil or hazardous material must meet the requirements of § 154.500 of this chapter. The transfer hose for oil must be annually hydrostatically tested at least 1.5 times the maximum allowable working pressure. The previous test was conducted in May 2021.
Action required: 703 - Prior to bunkering operations
Due 12 July 2022
Resolved 12 August 2022
Resolution: Hose tested and record retained onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 June 2022 Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. The alcohol test strips onboard were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 12 August 2022
Resolution: New alcohol test strips onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 June 2022 Resolved
Except as provided by § 15.725 of this part, no vessel may be navigated unless it has in its service and onboard the crew complement required by the COI. The vessel made more than one voyage with an individual serving as Master who was only endorsed as a Master of Towing Vessels on Western Rivers. Properly licensed Master required when carrying cargo or conducting bunkering operations (not-towing).
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2022
Resolved 12 August 2022
Resolution: Clarification of "occasional towing" made by OCMI and licensing requirements, owner notified.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 28 June 2022 Resolved
Fire detection, manual alarm, and supervised patrol systems are not required except in special cases; but if installed, the systems must meet the applicable requirements of 46 CFR, part 76. A framed chart or diagram must be installed in the wheelhouse or control station adjacent to the detecting cabinet indicating the location of the various detecting zones and giving instructions for the operation, maintenance, and testing of the system. The vessel master was unable to produce testing procedures or records for the installed fire detection system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 12 August 2022
Resolution: Diagram and instructions posted in the wheelhouse.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 June 2022 Resolved
As appropriate for the intended voyage, all vessels except barges, vessels operating exclusively on rivers, and motorboats other than those certificated for ocean or coastwise route, must carry adequate and up-to-date charts. The electronic and paper charts had not been updated.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2022
Resolved 12 August 2022
Resolution: Electronic chart system installed with automatic updates.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 June 2022 Resolved
The installation of all lifesaving appliances and arrangements must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. The port side ring buoy near the wheelhouse had degraded grab lines, worn retro-reflective tape, improperly secured light, and the light battery was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 12 August 2022
Resolution: Lifering replaced with a new one.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 June 2022 Resolved
The installation of all lifesaving appliances and arrangements must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. The life float did not have the required paddles and the painter line / weak link assembly was improperly installed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2022
Resolved 12 August 2022
Resolution: Paddles provided and weak link assembly with line properly installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 June 2021 Resolved
No means shall be provided for locking doors giving access to either of the two required means of escape. Doors had padlocks on the outside. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 92.10-20(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 19 November 2021
Resolution: Sent pictures of doors with padlock removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2021 Resolved
Furniture and furnishings. (a) For the purpose of this subpart, rooms containing “fire resistant furnishings” are considered to be those in which: (2) Case furniture such as bookshelves, desks, cabinets, counters, beds, or other freestanding furniture are constructed in accordance with the requirements in § 72.05-55 (a)(1) in subchapter H of this chapter. The Marine Inspector observed the furniture in the crew lounge included wooded bunk bed frames and regular mattresses. Owner to either remove, replace with fire resistant marine grade furniture, or provide proof that the mattresses and couches are fire resistant. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 116.423
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 9 February 2022
Resolution: Sent pictures of furniture being removed.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 June 2021 Resolved
Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. (2) Protection of passengers, crew, other persons, and the vessel from electrical hazards. The two electrical outlets at the galley sink need to be GFCI type outlets. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 111.01-1 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 19 November 2021
Resolution: Sent pictures of outlets ini galley with GFCI type outlets.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 June 2021 Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The Marine Inspector observed both of the fire control plans kept on board in the tubes at the port & starboard brows were waterlogged and unusable. Owner to reprint & replace with better watertight tubes as well. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 116.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 19 November 2021
Resolution: Sent pictures of replaced watertight tubing and new fire control plan.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 May 2020 Resolved
Each fire hose must be subjected to a test pressure equivalent to the maximum pressure to which it may be subjected during operation. However, each fire hose must be subjected to a pressure of at least 100 p.s.i.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2020
Resolved 11 June 2020
Resolution: Vessel provided a receipt of hoses being pressure tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2020 Resolved
If an approved size III, IV, or V fire extinguisher has wheels and is not required by Table 95.50–10(a), it must be securely stowed when not in use to prevent it from rolling out of control under heavy sea conditions.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2020
Resolved 11 June 2020
Resolution: Vessel supplied pictures of the BV secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 May 2020 Resolved
With the exception stated in paragraph (a)(2) of this section, it shall be the responsibility of the master to assure himself that all exposed cargo hatches and other openings in the hull. Main deck watertight door gasket needed replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2020
Resolved 11 June 2020
Resolution: Vessel crew installed a new gasket on door.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2020 Resolved
Life byoys on port and stbd pilot house rails need retro reflective tape replaced. (b) Type II—Weather resistant material used on continuously exposed rigid surfaces
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 11 June 2020
Resolution: Vessel crew replaced new reflective tape.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 May 2020 Resolved
Each hand portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least 1/2 inch high. Engine room fire extinguishers need to be labeled
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 11 June 2020
Resolution: Vessel's crew labeled all fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2020 Resolved
Batteries. Each battery used in a fire detecting and alarm system must meet Subpart 111.15 of this chapter Batteries did not have an expiration date and owner could not show documentation of last renewal. Replace with new batteries.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2020
Resolved 11 June 2020
Resolution: Vessel rep submitted a receipt of newly installed batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 May 2020 Resolved
Numerous pieces of equipment, stove, bunk beds, freezer, tool boxes) not properly secured. Vessel crew must secure equipment to make safe for operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2020
Resolved 11 June 2020
Resolution: Vessel rep supplied photos of all equipment secured in place.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 June 2019 Resolved
Multiple items in the medical kit were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 14 June 2019
Resolution: Expired items were replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 11 June 2019 Resolved
Main deck aft WTD was pad-lockable from outside instead of being lockable from the inside.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 14 June 2019
Resolution: Locking arrangement from the inside was installed on the aft WTD.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 April 2018 Resolved
Owner or Operator shal resubmit a Fire Control Plan in accordance with 46CFR 71.65-5 (d) using the icons from IMO Res. A.953(23). Fire Control plan is hand drawn and must be redrawn professionally for final approval by OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2018
Resolved 21 May 2018
Resolution: OCMI approved submitted plans that were verified by marine inspector onboard.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 June 2012 Resolved
Make permanent repairs to the holed fwd bulkhd in the engine room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2012
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 13 June 2012 Resolved
Repair/replace scored intermediate bearing on the stbd propeller shaft
Action required: 705 - Other - as specified
Resolved 20 September 2012
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 13 June 2012 Resolved
Repair seals on the P/S intermediate propeller shaft bearings in the shaft alley
Action required: 705 - Other - as specified
Resolved 20 September 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2012 Resolved
Repair wtd and bilge alarm indicator lights
Action required: 705 - Other - as specified
Resolved 10 October 2012
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 June 2012 Resolved
Clean and remove oily waste from the engine room bilges
Action required: 705 - Other - as specified
Due 18 September 2012
Resolved 18 September 2012
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 June 2012 Resolved
Replace stair treads leading from aft deck to passenger accommodation area
Action required: 705 - Other - as specified
Resolved 20 September 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 June 2012 Resolved
Replace first aid kit
Action required: 705 - Other - as specified
Resolved 10 October 2012
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 13 June 2012 Resolved
Clean/repair or remove stove in galley
Action required: 705 - Other - as specified
Resolved 10 October 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marine Type Label
Issued 13 June 2012 Resolved
Replace portable fire extinguishers that have illegible operating instructions
Action required: 705 - Other - as specified
Resolved 10 October 2012
Electrical › Electric Supply System (service) › Cable
Issued 13 June 2012 Resolved
Reattach electrical cables on rescue boat winch controller
Action required: 705 - Other - as specified
Resolved 10 October 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 June 2012 Resolved
Re-label life jacket storage to indicate location of child size life preservers
Action required: 705 - Other - as specified
Resolved 10 October 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 June 2012 Resolved
Repair inoperative emergency lights throughout the vessel
Action required: 705 - Other - as specified
Resolved 13 June 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 June 2012 Resolved
Repair broken welds on P/S vehicle gates
Action required: 705 - Other - as specified
Resolved 10 October 2012
Electrical › Electric Generation Source (service) › Power Requirement
Issued 8 December 2011 Resolved
1. To be completed by 15Dec2011 and prior to getting the vessel underway with passengers prove the proper operation of the STBD generator to the USCG. Currently the engine cannot be started.
Due 15 December 2011
Resolved 8 December 2011
Fire Fighting › Fire Pumps › Bearings
Issued 8 December 2011 Resolved
. To be completed by 15Dec2011 and prior to getting the vessel underway with passengers prove the operation of both fire pumps. Currently one has the clutch burnt out and the other cannot be run due to the generator that has the PTO cannot run.
Due 15 December 2011
Resolved 8 December 2011
Operations/Management › Drills/Instruction › Fire
Issued 8 December 2011 Resolved
3. To be completed by 15Dec2011 Complete the fire and boat drill that were not done due to the Generator and fire pump problems of 08Dec2011.
Due 15 December 2011
Resolved 13 January 2012
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 19 September 2011 Resolved
Remain at present location to complete repairs to the satisfaction of the attending Marine Inspector prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 20 September 2011
Resolution: Received tech report from company mechanic; replaced stbd 1-0-1 valve on clutch. Vsl optested satisfactorily.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 February 2011 Resolved
As per rule 27 inland navigation rules this vessel is required to have the not under command red all around lights on its mast.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 April 2011
Resolved 24 May 2011
Resolution: Proper navigation are installed on vessel as per rule 27 of the inland navigation rules
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 25 February 2011 Resolved
Repair stbd side throttle controls for both main engines n the pilot house.
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 24 May 2011
Resolution: New throttle controls have been installed for both main engines on the starboard side of the pilot house. New controls demonstrated to be working properly.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 25 February 2011 Resolved
Replace broken glass in the pilot house stbd side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 24 May 2011
Resolution: Glass replaced in starboard side of pilot house
Electrical › Electric Generation Source (service) › Ground Detection
Issued 25 February 2011 Resolved
Find and eliminate ground as indicated on switchboarda in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 24 May 2011
Resolution: Ground found and eliminated on switchboard in engine room
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 25 February 2011 Resolved
On both main engines the L/O shut down pressure switch (New AutoTest System) will not work as installed, position of the valve in the wrong location. Also the gauge needs to be a lower range type gauge. This will allow testing properly and reading the L/O pressure acurately.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 24 May 2011
Resolution: Proper gauge and proper location of vavle is installed on both main engines. Tested the operation of new installations. All satisfactory.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 25 February 2011 Resolved
Rescue Boat, replace the dead mans cable on the engine. Currently the cable is so tangled up it can not be used properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 24 May 2011
Resolution: Dead mans cable on the engine of the recue boat has been replaced and coan now be used properly
Construction/Loadline › Penetrations › Weld
Issued 25 February 2011 Resolved
Install proper stuffing rube penetration in the CO2 room where a new cable was run without the proper fittings.
Action required: 705 - Other - as specified
Due 25 March 2011
Resolved 24 May 2011
Resolution: Proper stuffing boxes are installed in CO2 room where new cable has been run
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 February 2011 Resolved
Prior to sailing with passengers re install the time delay bottle that blocks the manual pull "B" at the actual manual activation point. This was re located but to a wrong position.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2011
Resolved 28 February 2011
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 December 2010 Resolved
Repair emergency lighting at the forward main deck, shaft alley and rudder room.
Due 2 January 2011
Resolved 5 January 2011
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 2 December 2010 Resolved
Prove generator circuit breaker meets the requirements of 46CFR111.12
Due 2 January 2011
Resolved 5 January 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 December 2010 Resolved
Replace worn life ring lines
Due 2 January 2011
Resolved 5 January 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 December 2010 Resolved
Conduct and document crew training on the operation and safeguards concerning the fixed CO2 fire extinguishing system.
Due 2 January 2011
Resolved 5 January 2011
Navigation › Piloting/Steering › Compass Deviation Table
Issued 2 December 2010 Resolved
Update compass deviation card.
Due 2 January 2011
Resolved 5 January 2011
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 December 2010 Resolved
Renew/replace life jacket donning placards
Due 2 January 2011
Resolved 5 January 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 2 December 2010 Resolved
Replace portable fire extinguishers that have a marginal charge and those with worn and illegible operating instructions.
Due 2 January 2011
Resolved 5 January 2011
Lifesaving › Rescue Boat Equipment › Paddle/Oar
Issued 2 December 2010 Resolved
Replace rescue boat oars
Due 2 January 2011
Resolved 5 January 2011
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 2 March 2010 Resolved
3. To be completed prior to 09Mar2010: Port running light upper bulb inop. Change once and failed again. Trouble shoot and repair. Prior to night operations.
Action required: 705 - Other - as specified
Due 9 March 2010
Resolved 5 March 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 21 December 2009 Resolved
Repair/replace the holed MSD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 July 2009 Resolved
CO2 system test report completed by Louisiana Fire Extinguishing, Inc. dated 27Jul09 is not acceptable, complete re-testing of entire system is required and to be witnessed by a member of the crew. Report is not accurate as to condition of the CO2 system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 27 July 2009 Resolved
At engine room CO2 activation station, the instructions are wrong. There is currently no "C" handle to break glass for. New instruction labels are required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 27 July 2009 Resolved
In actual CO2 room there is no CO2 Siren in that compartment, Remove the siren sign that states leave space when siren is activated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 27 July 2009 Resolved
At the main pull station outside the port engine room entrance there is no CO2 diagram as required by 46CFR 76-15-10(h), Draft up and install diagram.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 July 2009 Resolved
Provide written engineering automation procedures with all details required to conduct engineering tests. Include tools needed, gauges to watch, set points, and what to expect when set points are reached.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 July 2009 Resolved
Prove proper operation of engineering automation IAW new automation procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 27 July 2009 Resolved
Prove the operation of all sounding tubes, reach rods, and remote operated valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 July 2009 Resolved
The engine room ventilation shutdown from the CO2 system is not working. It did not work previously even when the report from the Louisiana Fire Extinguishing Inc. stated all systems operational. Prove system to Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 27 July 2009 Resolved
Remove the fuel shut off sign at the bunker station, this is not a fuel shut off valve but is a beginning of line fill valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 27 July 2009 Resolved
Update station bill to correctly reflect crew compliment and vessel equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 July 2009 Resolved
Demonstrate proper operation of vent covers and dampers
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 27 July 2009 Resolved
Physically separate the child and adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 July 2009 Resolved
Replace lanyards on ring buoys float lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 July 2009 Resolved
Replace the float light on bridge ring buoys and properly install float light bracket on the stbd side of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2009
Resolved 28 August 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 30 January 2007 Resolved
Re-label placards for life rings and wipe down all life jackets.
Action required: 705 - Other - as specified
Resolved 6 March 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 January 2007 Resolved
Clean out all battery boxes of trash and fluids. Remove corrosion from battery terminals.
Action required: 705 - Other - as specified
Resolved 6 March 2007
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 30 January 2007 Resolved
Replace cable on hand control for rescue boat winch.
Action required: 705 - Other - as specified
Resolved 6 March 2007
Stability › Unintentional Flooding › General
Issued 30 January 2007 Resolved
Replace pin on hatch cover leading to MSD space.
Action required: 705 - Other - as specified
Resolved 6 March 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 January 2007 Resolved
De-scale and retard rust on plating and framing in MSD space.
Action required: 705 - Other - as specified
Resolved 6 March 2007
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 12 July 2006 Resolved
Repair "Low Control Air" alarm.
Action required: 705 - Other - as specified
Resolved 2 August 2006
Construction/Loadline › Structures › Superstructure
Issued 12 July 2006 Resolved
Repair stbd vehicle deck gate.
Action required: 705 - Other - as specified
Resolved 2 August 2006
Deck/Cargo › Mooring/Anchoring › Winch
Issued 12 July 2006 Resolved
Repair hand wheel for anchor windlass.
Action required: 705 - Other - as specified
Resolved 2 August 2006
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 12 July 2006 Resolved
Repair faucet in crews head.
Action required: 705 - Other - as specified
Resolved 2 August 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 July 2006 Resolved
Provide additional emergency lighting port and stbd engineroom aft.
Action required: 705 - Other - as specified
Resolved 2 August 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2006 Resolved
Conduct weight test of the fixed CO2 system cylinders.
Action required: 705 - Other - as specified
Resolved 12 April 2006
Engineering › Bilge Water Management System › Pump
Issued 8 March 2006 Resolved
Prove proper operation of the bilge pumping system.
Action required: 705 - Other - as specified
Resolved 4 April 2006
Lifesaving › Buoyant Apparatus › Float Free
Issued 8 March 2006 Resolved
Make proper repairs to the IBA canister mounting bracket.
Action required: 705 - Other - as specified
Resolved 4 April 2006
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 8 March 2006 Resolved
Prove proper operation of jacket water and oil pressure alarms on both gensets and main engines.
Action required: 705 - Other - as specified
Resolved 4 April 2006
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 6 December 2005 Resolved
Prove alarm panel in E/R and P/H provide an indication (audible and visual) for each alarm listed.
Action required: 705 - Other - as specified
Resolved 4 April 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 December 2005 Resolved
Ensure all electrical distribution panels can be properly closed.
Action required: 705 - Other - as specified
Resolved 4 April 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 August 2005 Resolved
Update fire safety plan.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Engineering › Steering Gear System › Hydraulic Hose
Issued 17 August 2005 Resolved
Replace marked hydraulic hoses on steering gear system in engineroom.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 17 August 2005 Resolved
Remove oil soaked rags and clean engine room bilges.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 17 August 2005 Resolved
Prove proper operation of the engine room alarm panel.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 17 August 2005 Resolved
Prove proper operation of the under voltage trips on both ships service generators.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 August 2005 Resolved
Update operating instructions.
Action required: 705 - Other - as specified
Resolved 18 October 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 February 2005 Resolved
replace counter weight on life jacket locker at port vehicle deck.
Action required: 705 - Other - as specified
Resolved 29 March 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 23 February 2005 Resolved
Repair jacket water leak on forward end of the stbd main engine.
Action required: 705 - Other - as specified
Resolved 29 March 2005
Engineering › Fuel Oil Service System › Hose
Issued 23 February 2005 Resolved
Replace as required, all fuel oil supply and return hoses on both main engines and gensets. Hoses shall meet SAE J1942 requirement for the intended service.
Action required: 705 - Other - as specified
Resolved 29 March 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 February 2005 Resolved
Remove excess water from battery boxes in engine room.
Action required: 705 - Other - as specified
Resolved 29 March 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 23 February 2005 Resolved
Plug holes in motor controllers for both control air compressors.
Action required: 705 - Other - as specified
Resolved 29 March 2005
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 23 November 2004 Resolved
Repair gauges on pilot house console for port main engine water temp and port shaft tach.
Due 15 December 2004
Resolved 20 January 2005
Engineering › Compressed Air System (start air) › Compressor
Issued 23 November 2004 Resolved
Replace flex hose at the discharge of the aft air compressor in the engineroom.
Due 15 December 2004
Resolved 20 January 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 November 2004 Resolved
Replace glass on ventillation shutdown for CO2 system.
Due 15 December 2004
Resolved 20 January 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 23 November 2004 Resolved
Renew operating instructions.
Due 15 December 2004
Resolved 20 January 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 November 2004 Resolved
Prove proper operation of the pilot house alarm panel.
Due 15 December 2004
Resolved 20 January 2005
Engineering › Compressed Air System (start air) › Compressor
Issued 18 May 2004 Resolved
Replace crushed oil filter on #2 air compressor.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Engineering › Bilge Water Management System › Pump
Issued 18 May 2004 Resolved
Install cover on bilge pump start/stop switch.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 May 2004 Resolved
Recharge/service fire extinguisher in engineroom.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Electrical › Electric Supply System (service) › Transformer
Issued 18 May 2004 Resolved
Repair stuffing tubes on transformer in engineroom.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Engineering › Steering Gear System › Ram
Issued 18 May 2004 Resolved
Replace pin on stbd steering gear hydraulic ram.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 18 May 2004 Resolved
Install cover on lighting fixture above steering pump in engineroom.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Engineering › Reduction Gearing/Clutches › Casing
Issued 18 May 2004 Resolved
Re-route and tighten hose on stbd reduction gear.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 May 2004 Resolved
Update compass deviation table.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 May 2004 Resolved
Make free, the retaining screws on ventilation dampers atop both stacks.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 May 2004 Resolved
Properly terminate cables on the mast headlight.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Lifesaving › Buoyant Apparatus › Marking
Issued 18 May 2004 Resolved
Remove old markings for life raft locations about the superstructure.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 18 May 2004 Resolved
Replace rescue boat winch cable and prove proper operation of the rescue boat NAVLTS.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 18 May 2004 Resolved
Provide working sink in restroom.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 May 2004 Resolved
Provide emergency lighting about the vehicle deck and rescue boat/IBA launching station.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 May 2004 Resolved
Provide bilge alarm for rudder room and shaft alley.
Action required: 705 - Other - as specified
Resolved 9 July 2004
Electrical › Electric Supply System (service)
Issued 18 November 2003 Resolved
Repair loose wiring on port side fan where it meets the switch box in passenger area. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 18 December 2003
Resolved 24 November 2003
Electrical › Electric Supply System (service)
Issued 18 November 2003 Resolved
Repair loose wiring on stbd side heater in passenger space. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 18 December 2003
Resolved 24 November 2003
Electrical › Electric Supply System (service)
Issued 18 November 2003 Resolved
Properly install/reconnect wiring on stbd side fan. Wiring should properly go through connector. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 18 December 2003
Resolved 24 November 2003
Engineering › Lubricating Oil Service System
Issued 18 November 2003 Resolved
Oil plug in CO2 room not secured. Plug does not properly secure/fasten. LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Due 18 December 2003
Resolved 24 November 2003
Engineering › Steering Gear System
Issued 18 November 2003 Resolved
Stbd side rudder angle indicator has only one nut, should be double nutted or drilled and pinned. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Engineering › Steering Gear System
Issued 18 November 2003 Resolved
Stbd side rudder stop outboard has a broken weld in way of angle clip. LEGACY COMPONENT DESC: Rudder
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Construction/Loadline › Penetrations
Issued 18 November 2003 Resolved
Port side aft wiring through-deck stub leaking water into aft steering. LEGACY COMPONENT DESC: Pipe Flange
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Construction/Loadline › Structures
Issued 18 November 2003 Resolved
Stbd side stern escape scuttle unable to be securely fastened. LEGACY COMPONENT DESC: Scuttle
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Engineering › Shafting/Propeller Arrangements
Issued 18 November 2003 Resolved
Stbd side shaft indicating sensor in sewage room loose/not securely fastened. LEGACY COMPONENT DESC: Propeller Shaft
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Engineering › Shafting/Propeller Arrangements
Issued 18 November 2003 Resolved
Port side intermediate shaft bearing shim stock loose/not properly mounted, in sewage room. LEGACY COMPONENT DESC: Bearing
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
Spare circuit breaker in breaker panel has improper breaker installed, the panel has a 70 amp breaker installed and the panel indicates a 20 amp should be installed. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper Installation
Due 18 December 2003
Resolved 24 November 2003
Electrical › Electric Generation Source (service)
Issued 18 November 2003 Resolved
Wiring on port and stbd generators is loose. Properly secure wiring. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
Ampmeter does not indicate/display amperage for port and stbd generators. Replace/repair ampmeters. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Accommodation/Occupational Safety › Potable Water System
Issued 18 November 2003 Resolved
Potable water tank is leaking. Properly repair leak from tank. LEGACY COMPONENT DESC: Tank
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
Overhead lighting above #2 generator and stbd engine has loose wiring. Properly mount/secure wiring. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Fire Fighting › Fire Pumps
Issued 18 November 2003 Resolved
Properly test or replace relief valves on #1 and #2 fire pumps at the pumps. Relief valves are not relieving at 125 psi. LEGACY COMPONENT DESC: Relief Valves
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Electrical › Electrical Distribution System (service)
Issued 18 November 2003 Resolved
Remove hard wiring to reefer in passenger area. Install electrical outlet to properly supply power to reefer. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 18 November 2003 Resolved
Secure reefer in passenger area to bulkhead.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Electrical › Lighting (service)
Issued 18 November 2003 Resolved
230 volt ground fault lights dim, hard to see with current white covers, install clear covers or brighter lights.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2003
Resolved 24 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 August 2003 Resolved
Prove proper operation of stbd main diesel engine low lube oil shutdown.
Condition: Improper/Lack of Maintenance
Due 27 August 2003
Resolved 27 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 August 2003 Resolved
Prove proper operation of port main diesel engine low lube oil shutdown, and overspeed alarm and shutdown.
Condition: Improper/Lack of Maintenance
Due 27 August 2003
Resolved 27 August 2003
Navigation
Issued 19 August 2003 Resolved
Prove proper operation of primary masthead light.
Condition: Improper Installation
Due 2 September 2003
Resolved 28 August 2003
Navigation › Piloting/Steering
Issued 24 June 2003 Resolved
Prove proper operation of the anchor light. Prior to vessel ever being anchored.
Condition: Unknown
Due 24 July 2003
Resolved 19 August 2003
Navigation › Piloting/Steering
Issued 21 May 2003 Resolved
Prior to placing vessel back in service, Properly repair the manual steering shaft in the steering compt. aft coupling with the chain sprocket. Machine shaft and sprocket for new key. Welding sprocket is not holding now. Welding again unsat. Key is shifting in key way and could shatter sprocket
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2003
Resolved 23 May 2003
Engineering › Compressed Air System (control)
Issued 21 May 2003 Resolved
Air compressors port side aft in engine room. Install guards on rotating parts. Guards are on shaft coupling but are required on the flywheel. LEGACY COMPONENT DESC: Compressor
Condition: Improper Installation
Due 21 June 2003
Resolved 24 June 2003
Communications › Internal Communications System
Issued 21 May 2003 Resolved
The sound powered phine in the steering compt. is barely understandable, little or no volume when talking to bridge. Can not hear the bridge very well when communicating. LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Unknown
Due 21 June 2003
Resolved 24 June 2003
Electrical › Electrical Distribution System (service)
Issued 21 May 2003 Resolved
Electrical distribution panel fwd in engine room, label index to include all apm ratings for each circut. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 21 June 2003
Resolved 24 June 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 May 2003 Resolved
Renew port MDE alarm covers, labels for the low lube oil pressure, low water level. Stbd MDE high water temp., gear oil pressure.
Due 21 June 2003
Resolved 24 June 2003
Communications › Internal Communications System
Issued 21 May 2003 Resolved
Sound powered phone on the bridge, label the selector to include the steering gear room. LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper Installation
Due 21 June 2003
Resolved 24 June 2003
Electrical › Electrical Distribution System (service)
Issued 21 May 2003 Resolved
Under the P/S bridge controls, replace wire nuts, properly dead end electrical wires, properly connect wires with butt connector splices. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 18 July 2003
Resolved 19 August 2003
Lifesaving › Launching Appliances
Issued 21 May 2003 Resolved
Renew rescue boat electrical wire for winch, currently wire has been pinched by moving parts and is being cut. LEGACY COMPONENT DESC: Davit
Condition: Damaged By Earlier Event
Due 21 June 2003
Resolved 24 June 2003
Electrical › Electrical Distribution System (service)
Issued 21 May 2003 Resolved
Batteries in the engine room port side fwd. Replace bare wires going to the batteries.
Condition: Improper/Lack of Maintenance
Due 21 June 2003
Resolved 24 June 2003
Navigation › Piloting/Steering
Issued 21 May 2003 Resolved
Renew the secondary stern light, currently burnt out.
Condition: Improper/Lack of Maintenance
Due 21 June 2003
Resolved 24 June 2003
Electrical › Electrical Distribution System (service)
Issued 21 May 2003 Resolved
Find and repair ground in 230 volt system. E/R ground fault light shows ground in one leg. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Due 24 July 2003
Resolved 25 June 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 May 2002 Resolved
Prove proper operation of starboard main diesel engine overspeed shutdown. LEGACY COMPONENT DESC: Governor
Condition: Unknown
Due 5 June 2002
Resolved 3 June 2002
Resolution: Item cleared.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 May 2002 Resolved
Prove proper operation of starboard main diesel engine low lube oil pressure shutdown.
Condition: Unknown
Due 5 June 2002
Resolved 3 June 2002
Resolution: Item cleared.
Operations/Management › Drug and Alcohol Testing
Issued 22 May 2002 Resolved
Provide proof of MIS form submitted to CG headquarters for CY 01. LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Due 5 June 2002
Resolved 3 June 2002
Resolution: Item cleared.
Lifesaving
Issued 22 May 2002 Resolved
Provide life saving equipment operational checklists in accordance with 46 CFR 199.190.
Condition: Unknown
Due 22 June 2002
Resolved 3 June 2002
Resolution: Item cleared.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 May 2002 Resolved
Conduct man overboard drill making recovery with rescue boat.
Due 22 May 2002
Resolved 3 June 2002
Resolution: Item cleared.
Engineering › Lubricating Oil Service System
Issued 19 February 2002 Resolved
Install and prove proper operation of main propulsion engine (both port and stbd) low lube oil pressure alarms and shutdowns. LEGACY COMPONENT DESC: Pump Prime Mover
Condition: Unknown
Due 29 March 2002
Resolved 2 April 2002
Construction/Loadline
Issued 22 August 2001 Resolved
CROP AND RENEW MANHOLE COVER TO SHAFT ALLEY.
Condition: Unknown
Due 22 August 2001
Resolved 22 August 2001
Navigation
Issued 22 May 2001 Resolved
REPAIR HYDRAULIC LEAK IN STEERING GEAR BOX.
Condition: Unknown
Due 22 June 2001
Resolved 29 May 2001
Fire Fighting
Issued 22 May 2001 Resolved
REDO FIRE PROCEDURES TO INCLUDE PA ANNOUNCEMENT BY THE CAPTAIN AND THE ADDITION OF AN EXTRA DECK HAND.
Condition: Unknown
Due 22 June 2001
Resolved 28 June 2001
Fire Fighting
Issued 22 May 2001 Resolved
REPAIR OR RENEW PORT FIRE PUMP AND PROVE PROPER OPERATION IN ACCORDANCE WITH 46 CFR 76.10-5.
Condition: Unknown
Due 18 August 2002
Resolved 16 August 2002
Resolution: Tested sat.
Engineering
Issued 22 May 2001 Resolved
HAVE FUEL TRANSFER PROCEDURE ONBOARD.
Condition: Unknown
Due 22 June 2001
Resolved 28 June 2001
Fire Fighting
Issued 22 May 2001 Resolved
#1 FIRE PUMP (PORT SIDE) PUMP DOES NOT SUPPLY ENOUGH WATER PRESSURE. VESSEL IS TO REPAIR ITEM PRIOR TO RETURNING TO OPERATION.
Condition: Unknown
Due 22 June 2001
Resolved 29 May 2001
Construction/Loadline
Issued 20 March 2001 Resolved
CROP AND RENEW FRACTURED SECTION OF DECK PLATE IWO DRAIN VENT AFT OF BATHROOM.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Construction/Loadline
Issued 21 February 2001 Resolved
Complete missing weld IWO port shaft flange through bulkhead in shaft compartment.
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Construction/Loadline
Issued 21 February 2001 Resolved
Gauge readings required to identify fracture at main deck IWO drain vent aft of bathroom.
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Construction/Loadline
Issued 21 February 2001 Resolved
Make proper and permanent repairs to #9 longitudinal in aft shaft compartment.
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Construction/Loadline
Issued 21 February 2001 Resolved
Ensure shaft compartment manhole cover properly seals.
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Construction/Loadline
Issued 21 February 2001 Resolved
Complete approx. 6" missing weld IWO port aft rudder compartment knuckle.
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Construction/Loadline
Issued 21 February 2001 Resolved
Properly weld fracture IWO stbd main beam diagonal brace next to MSD in shaft compartment.
Condition: Unknown
Due 21 February 2001
Resolved 21 February 2001
Navigation
Issued 28 August 2000 Resolved
REPAIR STEERING GEAR HYDRAULIC OIL LEAK AT CONTROL VALVE STBD SIDE AFT ENGINE ROOM.
Condition: Unknown
Due 28 August 2000
Resolved 30 August 2000
Electrical
Issued 28 August 2000 Resolved
LOCATE AND CORRECT ALL GROUND FAULTS ON VESSEL.
Condition: Unknown
Due 28 August 2000
Resolved 30 August 2000
Engineering
Issued 28 August 2000 Resolved
REPLACE TWO JACKET WATER HOSES ON PORT MAIN ENGINE AT AFT EXHAUST MANIFOLD UNDER MANIFOLD.
Condition: Unknown
Due 28 August 2000
Resolved 30 August 2000
Electrical
Issued 28 August 2000 Resolved
REPLACE PLASTIC WIRE TIES IN CO2 ROOM HOLDING CABLES WITH METAL TIES.
Condition: Unknown
Due 28 August 2000
Resolved 30 August 2000
Fire Fighting
Issued 28 August 2000 Resolved
REPLACE FIRE EXTINGUISHER BRACKET IN ENGINE ROOM FORWARD (NO.5).
Condition: Unknown
Due 28 August 2000
Resolved 30 August 2000
Accommodation/Occupational Safety
Issued 28 August 2000 Resolved
REPAIR RED FOX SANITATION DEVICE CURRENTLY PUMPING WATER OUT AIR INTAKE.
Condition: Unknown
Due 28 August 2000
Resolved 30 August 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Replace void sounding cover on #2.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Replace panama chock on port bow.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Replace panama chock on stbd bow.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Accommodation/Occupational Safety
Issued 23 May 2000 Resolved
Replace stbd fan in pax compt.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Weld two fractures by port gate latch.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Engineering
Issued 23 May 2000 Resolved
Prove operation of starboard eng gov. (Excessive hunt @ idle)
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Crop and renew brace port side e/r.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Crop and renew bracket port stern bull rail.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Reweld 45 degree angle stbd side fwd gate behind pin.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Reweld all painted areas on bull rail.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Weld crack in steering compt by escape hatch painted red.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Lifesaving
Issued 23 May 2000 Resolved
Replace wire rope on rescue boat winch.
Condition: Unknown
Due 23 May 2000
Resolved 23 May 2000
Construction/Loadline
Issued 1 December 1999 Resolved
MAKE PROPER REPAIR TO BULWARKS AT STARB. SIDE CAR GATE.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Construction/Loadline
Issued 24 November 1999 Resolved
WELD HOLES IN BULKHEAD OF RESCUE BOAT/EMERGENCY GEAR LOCKER ON MAIN DECK AND MAKE COMPARTMENT WEATHER TIGHT.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Construction/Loadline
Issued 24 November 1999 Resolved
POST APPROVED LOADING PLAN ON VESSEL.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Lifesaving
Issued 24 November 1999 Resolved
REPLACE RESCUE BOAT DAVIT WINCH WIRE WITH WIRE OF BETTER STRENGTH AND SUITABILITY FOR OPERATION WITH WINCH.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Navigation
Issued 24 November 1999 Resolved
MAKE REPAIRS TO ANCHOR LIGHT AND DEMONSTRATE.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Lifesaving
Issued 24 November 1999 Resolved
REINSTALL RESCUE BOAT DAVIT FLOODLIGHT.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Electrical
Issued 24 November 1999 Resolved
PERMANENTLY HARD WIRE ALL CONSTAVOLT SYSTEMS ( NO PLUG INS FOR PERMANENTLY INSTALLED SYSTEMS).
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Lifesaving
Issued 24 November 1999 Resolved
INSTALL PROPER HANDRAIL ON HURRICANE DECK AND INSTALL SAFETY CHAINS AT TOPSOF ESCAPE LADDERS.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Lifesaving
Issued 24 November 1999 Resolved
INSTALL GENERAL ALARM IN ENGINEERING SPACE AND DEMONSTRATE SAME.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Fire Fighting
Issued 24 November 1999 Resolved
REMOVE RAGS FROM CABLEWAYS BETWEEN DECKS IN PILOTHOUSE AND PROPERLY SEAL WITH FIRE RETARDENT MATERIAL.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Electrical
Issued 25 August 1999 Resolved
ADD RUBBER MAT BEHIND SWITCHBOARD AND REPLACE LABELS MISSING IN 115V 3 PHASE DISTRIBUTION PANEL IN ENGINE ROOM.
Condition: Unknown
Due 25 September 1999
Resolved 1 October 1999
Construction/Loadline
Issued 25 August 1999 Resolved
LABEL SEACHESTS IN ENGINE ROOM AND TIGHTEN PACKING NUTS ON STBD SEACHEST VALVE AND LABEL DISCONTINUED FUEL VALVE.
Condition: Unknown
Due 25 September 1999
Resolved 1 October 1999
Electrical
Issued 25 August 1999 Resolved
SECURE TOP COVER TO ENGINE ROOM SWITCHBOARD.
Condition: Unknown
Due 25 September 1999
Resolved 1 October 1999
Lifesaving
Issued 25 August 1999 Resolved
INSTALL COUNTER WEIGHTS ON ALL DECK LIFEJACKET BOXES TO ALLOW EASE OF OPENING.
Condition: Unknown
Due 25 September 1999
Resolved 1 October 1999
Electrical
Issued 25 August 1999 Resolved
PLUG THROUGH BULKHEAD BREACH BETWEEN RUDDER ROOM AND SHAFT ALLEY_x001C_ COMPARTMENT.
Condition: Unknown
Due 25 September 1999
Resolved 1 October 1999
Navigation
Issued 25 August 1999 Resolved
ADD BRACES TO STEERING RAM SUPPLY OIL PIPING BY VALVES IN RUDDER COMPARTMENT.
Condition: Unknown
Due 25 September 1999
Resolved 1 October 1999
Lifesaving
Issued 25 August 1999 Resolved
INSTALL OR PROVIDE FIRST AID KIT FOR RESCUE BOAT.
Condition: Unknown
Due 29 August 1999
Resolved 1 October 1999
Fire Fighting
Issued 25 August 1999 Resolved
ADD VENT DAMPERS TO EXHAUST STACKS AND DEMONSTRATE EXHAUST BLOWER DAMPERS AND LABEL SAME ON PASSENGER DECK.
Condition: Unknown
Due 25 September 1999
Resolved 1 October 1999
Navigation
Issued 25 May 1999 Resolved
PROVIDE MEANS TO SOUND WHISTLE WITH LOSS OF ELECTRICAL POWER.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Documentation
Issued 25 May 1999 Resolved
INSTALL FIRE MAIN DIAGRAM, OPERATING INSTRUCTIONS AND ALIGNMENT DIAGRAMS.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Documentation
Issued 25 May 1999 Resolved
INSTALL BILGE SYSTEM DIAGRAMS AND OPERATING INSTURCTIONS AND ALIGNMENT DIAGRAMS.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Lifesaving
Issued 25 May 1999 Resolved
PERMANENTLY LABEL ALL DECK FITTINGS.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Engineering
Issued 25 May 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Construction/Loadline
Issued 25 May 1999 Resolved
REPLACE 4 RAIL SUPPORTS ON STBD SIDE AS MARKED.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Construction/Loadline
Issued 25 May 1999 Resolved
GOUGE AND REWELD RAIL SUPPORTS AS MARKED.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Navigation
Issued 25 May 1999 Resolved
REPAIR COMPASS AND PROVIDE COMPASS DEVIATION TABLE FOR SAME.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Lifesaving
Issued 25 May 1999 Resolved
REMOVE OIL AND CLEAN ENGINE ROOM BILGES.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Documentation
Issued 25 May 1999 Resolved
INSTALL CO2 PIPING DIAGRAM AND OPERATING INSTRUCTIONS.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Navigation
Issued 20 April 1999 Resolved
INSTALL LIMIT SWITCHES FOR STEERING SYSTEM.
Condition: Unknown
Due 20 May 1999
Resolved 5 May 1999
Navigation
Issued 20 April 1999 Resolved
REPARI USING APPROVED PLANS, THE JOCKEY BAR FOR STEERING SYSTEM. INSTALL SUPPORT ROLLER FOR JOCKEY BAR.
Condition: Unknown
Due 20 May 1999
Resolved 5 May 1999
Accommodation/Occupational Safety
Issued 2 March 1999 Resolved
REPAIR DECK, STBD SIDE AFT, IN PASSENGER COMPARTMENT.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Lifesaving
Issued 2 March 1999 Resolved
REPLACE FWD GENERAL ALARM ON FRONT OF PILOT HOUSE.
Condition: Unknown
Due 9 March 1999
Resolved 10 March 1999
Navigation
Issued 2 March 1999 Resolved
PROVIDE PROPER RUNNING LIGHTS FOR RESCUE BOAT.
Condition: Unknown
Due 9 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 1 December 1998 Resolved
PROVIDE/INSTALL PROPER FIRE EXT. BRACKETS IAW MFG APPROVAL NUMBER ON INDIVIDUAL EXTINGUISHERS TOW TO THREE TYPES ARE NEEDED._x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Electrical
Issued 1 December 1998 Resolved
PROPERLY LABEL AND OR INSTALL PROPER CIRCUIT BREAKERS ON THE FOLLWOING E/R SWITCH BOARD BREAKERS. A) SEWER BREAKER LABELED 15A 20A INSTALLED_x001C_ B) MAIN BILGE PUMP LABELED 20A 15A INSTALLED_x001C_ C) SPARE LABELED 20A 40A INSTALLED._x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Unknown
Issued 1 December 1998 Resolved
REPAIR SOUND POWERED PHONE COMMUCICATIONS BETWEEN BRIDGE AND ENGINE ROOM, UNTIL REPAIRED PORTABLE COMMS TO BE USED.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Navigation
Issued 1 December 1998 Resolved
REPAIR LEAKS IN STEERING GEAR PUMPS/FITTINGS LOCATED IN E/R AFT STBD SIDE._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 2 December 1998
Electrical
Issued 1 December 1998 Resolved
FIND GROUND FAULT IN 115 VOLT GROUND TEST LAMPS.
Condition: Unknown
Due 4 January 1999
Resolved 2 December 1998
Accommodation/Occupational Safety
Issued 2 September 1998 Resolved
SECURE DECK PLATE IN ENGINE ROOM TO DECK FRAMES.
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Electrical
Issued 2 June 1998 Resolved
CLEAR GROUNDS IN 230V ELECTRICAL SYSTEM.
Condition: Unknown
Due 8 June 1998
Resolved 25 June 1998
Lifesaving
Issued 2 June 1998 Resolved
PROVE PROPER OPERATION OF HIGH WATER TEMPERATURE ALARMS ON AL P/S MDE'S & P/S SSG'S.
Condition: Unknown
Due 8 June 1998
Resolved 25 June 1998
Engineering
Issued 2 June 1998 Resolved
PROVE PROPER OPERATION OF PORT MDE OIL PRESSURE GUAGE.
Condition: Unknown
Due 8 June 1998
Resolved 25 June 1998
Electrical
Issued 2 June 1998 Resolved
CLEAR GROUNDS IN 110V ELECTRICAL SYSTEM.
Condition: Unknown
Due 8 June 1998
Resolved 25 June 1998
Engineering
Issued 2 June 1998 Resolved
PROVE PROPER OPERATION OF ALL ALARMS ON STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 2 June 1998
Resolved 25 June 1998
Navigation
Issued 5 June 1997 Resolved
INSTALL APPROVED WHISTLE LIGHT APPLIANCE AND APPROVED LIGHT.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Engineering
Issued 5 June 1997 Resolved
INSTALL PROPER OIL PRESSURE SENDING UNIT IN ENGINE ROOM IN WAY OF PORT MAINENGINE.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Lifesaving
Issued 16 April 1997 Resolved
PROVIDE AN OUTBOARD MOTOR PROPELLED RESCUE BOAT AND DAVIT FOR LAUNCHING.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Lifesaving
Issued 5 March 1997 Resolved
PROVIDE AN OUTBOARD MOTOR PROPELLED RESCUE BOAT AND DAVIT FOR LAUNCHING.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Electrical
Issued 10 December 1996 Resolved
INSTALL NEW ENGINE OIL PRESSURE GAUGE FOR PORT GENERATOR IN ENGINE ROOM.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Engineering
Issued 10 December 1996 Resolved
INSTALL NEW ENGINE OIL PRESSURE GAUGE FOR PORT MDE ON PORT SIDE OF BRIDGE CONSOLE.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Accommodation/Occupational Safety
Issued 29 April 1996 Resolved
MAKE DECK SCUTTLES OPERABLE FROM BELOW DECK IN THE STEERING GEAR SPACE AND SPACE FWD OF STEERING GEAR SPACE AND MARK IAW 46 CFR 78.47-40.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Electrical
Issued 29 April 1996 Resolved
INSTALL AND PROVE PROPER OPERATION OF EMERGENCY LIGHTING, IN STEERING GEAR SPACE AND SPACE FWD OF STEERING GEAR SPACE, IAW 46 CFR 112.15.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Accommodation/Occupational Safety
Issued 6 March 1996 Resolved
PROVE TYPE AND COAST GUARD APPROVAL OF INSTALLED MARINE SANITATION DEVICE.
Condition: Unknown
Due 6 April 1996
Resolved 7 March 1996
Electrical
Issued 6 March 1996 Resolved
INSTALL AND PROVE PROPER OPERATION OF EMERGENCY LIGHTING, IN STEERING GEAR SPACE AND SPACE FWD OF STEERING GEAR SPACE, IAW 46 CFR 112.15.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Accommodation/Occupational Safety
Issued 6 March 1996 Resolved
MAKE DECK SCUTTLES OPERABLE FROM BELOW DECK IN THE STEERING GEAR SPACE AND SPACE FWD OF STEERING GEAR SPACE AND MARK IAW 46 CFR 78.47-40.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 20 December 1994 Resolved
REMOVE ALL FLAMMABLE MATERIAL AND LIQUIDS STOWED UNDER BRIDGE CONTROL CONSOLE.
Condition: Unknown
Due 20 January 1995
Resolved 20 December 1994
Fire Fighting
Issued 20 December 1994 Resolved
MOUNT FIXED CO2 BOTTLES TO PROVIDE AT LEAST 2 INCHES BETWEEN FLOORING AND BOTTOM OF CYLINDERS.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Electrical
Issued 20 December 1994 Resolved
PROPERLY BAND ELECTRICAL WIRING IN CO2 ROOM AND ENGINEROOM BESIDE GENERATORSWITCHBOARD WITH METAL BANDING.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994

Casualty record · 8

9 March 2005Routine · role: Involved in a Marine Casualty · activity 2310584
4 January 2006Routine · role: Involved in a Marine Casualty · activity 2590446
5 January 2007Routine · role: Involved in a Marine Casualty · activity 2852249
21 November 2009Routine · role: Involved in a Marine Casualty · activity 3639008
12 December 2009Routine · role: Involved in a Marine Casualty · activity 3658858
15 September 2010Routine · role: Involved in a Marine Casualty · activity 3852856
19 September 2011Routine · role: Involved in a Marine Casualty · activity 4150680
8 December 2011Routine · role: Involved in a Marine Casualty · activity 4204491
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.