Inspection history · 7
13 October 2020
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7071841
10 October 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7071843
29 January 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6616711
3 July 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6458878
17 May 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6148273
10 May 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6138671
15 December 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6058539
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 October 2020
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. LANYARD REQUIRED FOR KILLSWITCH IS MISSING TO PROPERLY START RESCUE BOAT.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2020
Resolution: Vessel aquired new kill switch lanyard. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 October 2020
Resolved
A FOOD RATION TOTALLING NOT LESS THAN 10,000KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMODATE; THESE RATIONS SHALL BE KEPT IN AN AIRTIGHT PACKAGING AND BE STORED IN A WATERTIGHT CONTAINER. 04 OUT OF 20 REQUIRED RATIONS HAD LOST AIRTIGHT QUALITY.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2020
Resolution: Vessel acquired provisions. Deficiency Rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 October 2020
Resolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. 02 CLASS A BOUNDARY DOORS IN GALLEY WERE SECURED OPEN WITH HOLD-BACK HOOKS.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 October 2020
Resolution: Crew removed door hold backs. Deficiency Rectified.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 October 2020
Resolved
EACH VESSEL MUST HAVE THE FOLLOWING: SIMPLE OPERATING INSTRUCTIONS WITH A BLOCK DIAGRAM PERMANENTLY DISPAYED ON THE NAVIGATION BRIDGE AND IN THE STEERING GEAR COMPARTMENT. VESSEL DOES NOT HAVE A BLOCK DIAGRAM DISPLAYED IN THE STEERING GEAR COMPARTMENT.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 October 2020
Resolution: Crew posted block diagram in steering space. Deficiency Rectified.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 July 2018
Resolved
0725-Fixed Fire Extinguishing Installation- Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed water mist system supply valve and individual engine room space valve in the closed postion. Crew moved to open position.
SOLAS 74 (2014) Ch. II-2/14.2.1.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 3 July 2018
Resolution: Crew moved valves to open position
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 July 2018
Resolved
0715-Detection- The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Fire detection and fire alarm systems; Crew was unable to demonstrate operation of fire detection or fire alarm systems due to multiple inoperable flame detectors. Crew was able to change sensors and test flame detectors and fire alarm system satisfactorily.
SOLAS 74(2014) Ch. II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 July 2018
Resolution: Crew changed sensors.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 July 2018
Resolved
2535-Development of Plans for shipboard ops- Every company should develope, implement, and maintain a safety management system which includes the following functional requirements: Instructions and procedures to ensure safe operation of the ship. Vessel did not have procedures for testing watermist system.
SOLAS 74 (2014)Ch. IX/3.1 ISM Code 1.4.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 29 January 2019
Resolution: Procedures for testing water mist now available onboard and included in PMS.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 July 2018
Resolved
2535-Development of plans for shipboard ops- Every company should develope, implement, and maintain a safety management system which includes the following functional requirements: Instructions and procedures to ensure safe operation of the ship. Vessel did not have procedures for flame detector testing.
SOLAS 74 (2014) Ch. IX/3.1 ISM Code 1.4.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 20 July 2018
Resolution: Received procedures for testing flame detector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 July 2018
Resolved
0730-Appliances (General Equipment)- Flame detectors shall be tested according to standards EN 54-10:2001 and IEC 100095-504. Alternative testing standards may be used as determined by the administration. Flame detectors could not be tested by approved means and were inoperable. Provided approved test equipment.
SOLAS 74 (2014) Ch. II-2/7.2.2 FSS Code Ch.9.2.3.1.5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 20 July 2018
Resolution: Received documented procedures stating test equipment.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 10 May 2017
Resolved
Fire-Fighting systems shall be kept in good working order and readily available for immediate use. Water mist system above D.O. purifier found with nozzle head missing and pipe end obstructed.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 10 May 2017
Resolved 26 May 2017
Resolution: Nozzle replaced with spare on board on pipe over D.O purifier. Visually verified by USCG.