Records from 2016 to 2022. Most recent: inspection, 30 August 2022.
Inspection history · 8
30 August 2022
PSC B · Deficiency Check · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7540893
20 June 2021
PSC B · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7230087
16 May 2020
COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6951813
14 August 2019
NPV Safety Exam · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6782328
13 August 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6830195
13 May 2019
COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6674441
15 April 2018
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6391607
22 May 2016
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5876196
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 30 August 2022
Resolved
Doors to an Air-Lock should be self-closing and without any hold back arrangements. Vessel has an Air-Lock on the motor room entrance. PSCOs observed the absence of any self-closing arrangements on the outer Air-lock door. In addition, a hold back arrangement was identified on the exterior bulkhead of the motor room.
Cite: 74SOLAS(20) VII/13.1 - IGC(93) 3.6.2
Action taken: 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2022
Resolved 14 September 2022
Resolution: Received vessel operator and class society documentation attesting to class approved repairs and satisfactory operational testing of self-closing air-lock arrangement.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 August 2022
Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. PSCOs observed a certified safe crew notification light on top of the cargo compressor room phone booth, that appeared to not be gas-tight. Improper cable gland with rubber gasket was installed.
Cite: 74SOLAS(20) VII/13.1 IGC(93) 10.1.2
Action taken: 16AC
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2022
Resolved 14 September 2022
Resolution: Received vessel operator and class society documentation attesting to proper plug replacement to the satisfaction of vessel's class society.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 August 2022
Resolved
All liquid and vapor connections should have shut-off valves located as close to the tank as practicable. These valves may be remotely controlled and provide full closure. PSCOs observed 03 COT liquid fill valves to not open fully when tested.
74SOLAS(20) VII/13.1 - IGC(93) 5.6.1.1
Action taken: 10C
Action required: 10 - Deficiency Rectified
Due 30 August 2022
Resolved 30 August 2022
Resolution: Crew dismantled pneumatic fill valves and made the necessary adjustments. Crew re-tested and showed video evidence to PSCOs onboard prior to end of exam.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 August 2022
Resolved
On ships carrying flammable or toxic products or both, a water-spray system shall be installed and capable of uniform distribution. PSCOs observed 06 clogged nozzles.
74SOLAS(20) VII/13.1 - IGC(93) 11.3.1
Action taken: 10C
Action required: 10 - Deficiency Rectified
Due 30 August 2022
Resolved 30 August 2022
Resolution: Crew cleared clogged nozzles.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 August 2019
Resolved
Ships shall automatically transmit the following long-range identification and tracking information: identity of ship, position of ship, and date/time of the position provided (LRIT). Vessel allided LRIT antenna with bridge during inbound transit due to improper keel to highest point measurement with air draft calculations. Vessel required to have LRIT technician attend and attest to operation of LRIT. Vessel required to have classification society attend and attest to technician report, proper re-installatin of LRIT antenna, and verify distance between keel and highest point of vessel. 74SOLAS(14)V/19-1.4.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2019
Resolved 14 August 2019
Resolution: Vessel provided satisfactory technician report, class report attesting to satisfactory operation of LRIT, air draft calculations.