MAURY USCG vessel records Sign in
← All vessels

STARFISH ENTERPRISE

STARFISH ENTERPRISE is a 2009 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2009, most recently in September 2025, along with 19 deficiencies.

Records from 2009 to 2025. Most recent: inspection, 3 September 2025.

Built
2009
Last inspected
3 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE8920
1001120
Flag
UNITED STATES
367411240
Maury page id
psix-1001120

Inspections, by type

Years with a record 15 calendar years (2009–2025)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)51.3 ft × 19.2 ft × 6.2 ft
Registered tonnagegross 40 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderH & H MARINE INC · STEUBEN, ME, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portEASTPORT, ME
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE8920MMSI 367411240 · active · compulsorily equipped · granted 4 April 2019, expires 22 May 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

3 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8158058
24 April 2025 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8103413
5 June 2024 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7921745
6 September 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7785254
16 March 2023 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7651850
1 September 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7548879
27 April 2021 DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7183732
15 October 2020 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7077641
3 April 2019 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6655400
13 August 2018 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6510732
12 September 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6264823
3 May 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6138580
23 August 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5980663
10 September 2015 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5221913
27 May 2014 Deficiency Check · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4870735
8 September 2011 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4140274
27 September 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3858631
10 February 2009 Simplified Stability Test · Hull Examination · Initial Certification · Construction Oversight
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3500093

Deficiency record · 19

Fire Fighting › Fire Pumps › Power Source
Issued 12 September 2017 Resolved
Repair the hydraulic system for the fire/bilge pump; vls restricted to <49 pax.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2017
Resolution: Corrected
Communications › Alarms/Indicators › High Water Alarm
Issued 12 September 2017 Resolved
Repair the auto bilge pump indicating system
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 4 October 2017
Resolution: Corrected
Engineering › Bilge Water Management System › Interface Detector
Issued 9 September 2016 Resolved
Steering room indicator light for the high water alarm/light did not work; repair or replace light.
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 26 September 2016
Resolution: High water alarm light was repaired.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 September 2016 Resolved
01 PFD was condemed, vsl was short 7 adult PFDs; total adult PFDs on board as required on COI is 82. Vsl restricted to 74 total persons onboard until new PFDs are onboard.
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 26 September 2016
Resolution: 08 new adult lifejackets were purchased to meet the vsl's total pfd count.
Construction/Loadline › Penetrations › Gasket
Issued 10 September 2015 Resolved
Repair/Replace gasket to hatch in starboard lazaret hatch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 October 2015
Resolved 22 October 2015
Resolution: Received photo of new gasket in place.
Engineering › Fuel Oil Service System › Filter
Issued 10 September 2015 Resolved
Replace petcock on fuel filter with plug.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 October 2015
Resolved 22 October 2015
Resolution: Received photo of new plug with filter.
Lifesaving › Hand Flares › Quantity
Issued 10 September 2015 Resolved
Provide 2 additional orange smoke and 2 additional red hand flares, OR 4 additional red hand flares.
Due 10 October 2015
Resolved 22 October 2015
Resolution: Rceived proof of new flares purchased.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 June 2014 Resolved
Replace lanyard(s) connected to life float(s) for both floating electric water lights.
Due 23 June 2014
Resolved 23 June 2014
Resolution: Operator replaced both lanyards.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 June 2014 Resolved
Provide listed of covered employees under drug consortium.
Due 23 June 2014
Resolved 23 June 2014
Resolution: Operator provided list of covered employees.
Electrical › Electrical Distribution System (service) › Switch
Issued 16 June 2014 Resolved
Label electrical switches at operating station.
Due 23 June 2014
Resolved 23 June 2014
Resolution: Operator labeled electrical switches at operating station.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 September 2011 Resolved
Prove proper operation of 1 lifefloat waterlight.
Condition: Improper/Lack of Maintenance
Due 8 October 2011
Resolved 27 September 2011
Engineering › Bilge Water Management System › Not Operational
Issued 8 September 2011 Resolved
Bilge high water indicator light for E/R not operational.
Condition: Improper/Lack of Maintenance
Due 8 October 2011
Resolved 27 September 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 September 2010 Resolved
Prove proper operation of vessel rescue lights.
Condition: Improper/Lack of Maintenance
Due 27 October 2010
Resolved 22 October 2010
Fire Fighting › Fire Pumps › Pressure
Issued 27 September 2010 Resolved
Prove proper operation of fire pump gauge.
Condition: Improper/Lack of Maintenance
Due 27 October 2010
Resolved 22 October 2010
Engineering › Fuel Oil Service System › Valve
Issued 27 September 2010 Resolved
Provide marking for fuel shutoffs.
Condition: Improper Installation
Due 27 October 2010
Resolved 22 October 2010
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 27 September 2010 Resolved
Provide spacers for buoyant apparatus.
Condition: Improper Installation
Due 27 October 2010
Resolved 22 October 2010
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 10 February 2009 Resolved
Submit "as built" electrical plan to MSD Belfast.
Action required: 705 - Other - as specified
Due 9 September 2009
Resolved 16 April 2010
Resolution: Details of changes to the electrical plan were submitted and are minor in nature. Submittal of an entirely new plan will not be necessary. The changes made were reviewed with no deficiencies noted.
Lifesaving › Lifefloat › Quantity
Issued 10 February 2009 Resolved
Provide a 22 person lifefloat. Vessel is restricted to carrying not more than 62 total persons on board when operating beyond 3 miles LBS or any Limited Coastwise route until cleared.
Action required: 705 - Other - as specified
Due 9 August 2009
Resolved 7 October 2009
Resolution: Owner advised that new 22 person lifefloat was received and has been installed onboard.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 February 2009 Resolved
Provide cover for panelboard IWO stereo amplifier.
Action required: 705 - Other - as specified
Due 16 July 2009
Resolved 7 October 2009
Resolution: Owner advised that cover has been provided.

Ownership record