BLUE WARRIOR

BLUE WARRIOR is a 1973 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2025, along with 14 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 12 May 2025.

Built
1973
Last inspected
12 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1001675
Flag
UNITED STATES
Maury page id
psix-1001675

Documentation record

Registered dimensions (L × B × D)36.0 ft × 12.3 ft × 7.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM, WA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTH LAKE TAHOE, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

12 May 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8139378
16 May 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7908370
25 April 2024 Internal Structural Exam · Hull Examination · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7902010
18 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7685935
3 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7446793
29 April 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179401
19 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6987140
29 May 2020 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6967408
14 November 2019 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6858517
13 May 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681340
23 April 2019 Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6670578
21 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6417069
12 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6147023
2 June 2016 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5895165

Deficiency record · 14

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 May 2025 Resolved
Firefighting drills shall be logged and include the following: date of drill and general description of the drill scenario and training topics. Last fire/MOB drill logged was May 2025. 46 CFR 185.524
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 15 May 2025
Resolution: Operator logged appropriate drill
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2025 Resolved
Each floating waterlight must be attached to the lanyard with a corrosion resistant clop...and allow the waterlight to be quickly disconnected from the ring life buoy. Waterlight was spliced to buoy. 46 CFR 180.70 (d)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 15 May 2025
Resolution: Operator installed clip on waterlight line
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2024 Resolved
The owner or managing operator must provide satisfactory evidence of required fire protection equipment servicing to the marine inspector. Vessel operator to provide corresponding fire servicing report. 46 CFR 176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 22 May 2024
Resolution: Verified fire servicing equipment annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 May 2024 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with procedures detailed in 49 CFR part 40. Vessel to provide the following: all negative tests of covered employees in the past year, 2023 MIS report, 2 pre-employment testing, and letter of regulatory compliance from consortium. 46 CFR 16.201(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 18 June 2024
Resolution: Verified all applicable items for the deficiency.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 May 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Fixed and portable fire extinguishers have expired annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 May 2022
Resolution: Vessel hired fire inspector while MIs were onboard. All fire extinguishers and systems inspected by third party.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 May 2022 Resolved
Any vessel of at least 5 net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement. Vessel has expired COD.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 June 2022
Resolved 19 June 2022
Resolution: NVDC and PSIX are reporting that COD has been successfully attained with Coastwise endorsement.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 June 2020 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under §67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. The vessel did not have a valid COD onboard during the annual inspection. 46 CFR 67.7
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Operator submitted application for renewal COD in the presence of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2019 Resolved
A vessel on a lakes, bays and sounds, or rivers route must carry three hand red flare distress signals approved in accordance with 160.021 in Subchapter Q of this chapter and three orange smoke distress signals in accordance with 160.037 in subchapter Q of this chapter. Vessel does not have three hand orange smoke distress signals as required. 46CFR180.68(b) code 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 May 2019
Resolved 15 May 2019
Resolution: Vessel procured additional distress signals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2019 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the normally unmanned spaces. Audible alarm at the upper operating station is inoperable. 46CFR182.530(a) code 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: Vessel installed new bilge alarm; tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019 Resolved
Starboard navigation light is inoperable and port navigation light cover is broken. Rectify prior to conducting operations at night or in restricted visibility. Nav Rules, Rule 23. Code 705c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 15 May 2019
Resolution: Vessel completed satisfactory temp repair and provided proof of order for new/permanent lens.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 May 2019 Resolved
A substantial nameplate must be permanently attached to each buoyant apparatus. Nameplate on buoyant apparatus is painted over and not visible. Rectify per manufacturer’s or approved servicing facility’s specifications and provide documentation or reduce COI route to 1 mi. Vessel is restricted to within 1 mile of shore until correction; liferaft must be servicable or COI amended prior to the end of the operating season. 46CFR160.010-8 code 50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 19 June 2020
Resolution: Operator provided picture of nameplate, USCG approval number, and sufficient capacity.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 May 2019 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon requires. Drills logs were not available for inspection. Additionally, lifesaving maintenance records were not available for inspection. 46CFR185.520(f)&.420(c) code 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 May 2019
Resolved 13 May 2019
Resolution: Vessel created log entry for inspections/drills conducted at inspections and will train captains on responsibilities.
Engineering › Fuel Oil Service System › Valve
Issued 12 May 2017 Resolved
Prover proper operation of starboard side emergency fuel shutoff valve. 46CFR182.455(b)(4)
Condition: Improper/Lack of Maintenance
Due 12 May 2017
Resolved 12 May 2017
Resolution: Observed proper operation of emergency fuel shutoff valve.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 12 May 2017 Resolved
Service overdue fire extinguishers. 46CFR181.500
Condition: Improper/Lack of Maintenance
Due 12 June 2017
Resolved 12 May 2017
Resolution: Fire extinguishers serviced.