JENNY LEIGH III

JENNY LEIGH III is a 2009 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2026, along with 11 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 27 May 2026.

Built
2009
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1001920
Flag
UNITED STATES
Maury page id
psix-1001920

Documentation record

Registered dimensions (L × B × D)34.0 ft × 11.0 ft × 4.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2009
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portMOOSE, WY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

27 May 2026 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319422
27 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106654
29 May 2024 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7922791
9 May 2023 COI Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684305
1 June 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7412294
2 June 2021 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7175784
8 October 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073874
7 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6999934
4 June 2019 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690448
8 June 2018 Internal Structural Exam · Deficiency Check · Administrative Inspection · DAPI Audit · COI Inspection · Drydock Exam · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429971
13 July 2017 Administrative Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6223313
7 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6206457
7 June 2017 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6142875
16 May 2016 Deficiency Check · DAPI Audit · Special · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5878636

Deficiency record · 11

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024 Resolved
46CFR182.460(a)((1)ii) An enclosed space containing fuel tanks for gasoline must have a ventilation system consisting of a mechanical exhaust system with at least two ventilation exhaust ducts located at the end of the space opposite from where the supply ducts are fitted, which extend to the lowest part of the bilge of the space on each side of the space, and which are led to one or more exhaust blowers. Noted that vessel only had one exhaust duct connected to the mechanical exhaust system. Rectify within 30 days.
Action required: 705 - Other - as specified
Due 29 June 2024
Resolved 25 June 2024
Resolution: exhuast ducts properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024 Resolved
46CFR182.460(e) Exhaust blower switches must be of the type interlocked with starting switch and the ignition switch so that the blowers are started before the starter motor circuit or engine ignition is energized. Noted there was no interlock between blower and ignition switch, vessel was able to operate without blower being energized. Prove proper operation within 30 days.
Action required: 705 - Other - as specified
Due 29 June 2024
Resolved 25 June 2024
Resolution: interlock properly installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 June 2022 Resolved
The bilge high level alarms are wired to operate when the engine ignition is in the off position. Prove that all bilge high level alarms function while vessel engines are in the on position and running.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 7 June 2022
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 June 2021 Resolved
Prove proper servicing of the fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 June 2021
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2019 Resolved
Ring Buoy found with deteriorating grab line due to UV degradation. Provide proof of serviceable approved ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2019
Resolved 2 July 2019
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 7 June 2017 Resolved
Ensure a fire retardant foam is installed on the vent closures.
Condition: Design Flaw
Due 14 July 2017
Resolved 12 July 2017
Engineering › Fuel Oil Service System › Hose
Issued 7 June 2017 Resolved
Replace the damaged (chewed up) port fuel tank hose. Ensure the hose meets the SAE flexible hose standard listed in subchapter T.
Condition: Improper/Lack of Maintenance
Due 7 July 2017
Resolved 7 July 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 June 2017 Resolved
Replace the outboard chafed hydraulic hose. Ensure the hose meets the SAE flexible hose standard listed in subchapter T.
Condition: Improper/Lack of Maintenance
Due 7 July 2017
Resolved 7 July 2017
Communications › Audible Communications › Horn/Whistle
Issued 7 June 2017 Resolved
Ensure proper operation of the vessel’s installed horn.
Condition: Invalid
Due 7 July 2017
Resolved 7 July 2017
Engineering › Bilge Water Management System › Pump
Issued 7 June 2017 Resolved
Ensure that the activation of the aft fuel compartment high level bilge alarm does not also energize the forward bilge pump.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 7 July 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 31 May 2016 Resolved
Re-secure the Velcro on the air vents.
Condition: Improper/Lack of Maintenance
Due 15 June 2016
Resolved 14 June 2016

Ownership record