MAURY USCG vessel records
← All vessels

NORTHERN DEFENDER

NORTHERN DEFENDER is a 2007 freight ship. The Coast Guard has recorded 7 inspections since 2019, most recently in August 2021, along with 3 deficiencies and 2 operational controls.

Records from 2019 to 2021. Most recent: inspection, 2 August 2021.

Built
2007
Last inspected
2 August 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 August 2021
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2019–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9329643
1002482
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1002482

Documentation record

Tonnage as PSIX records it42121 - Dead Weight, Ton
56951 - Displacement, Ton
35975 - Convention (Subpart B), Gross Ton
15938 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

2 August 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7273371
5 January 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7119684
15 April 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6939293
29 August 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6798374
26 August 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6794673
15 July 2019 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6750478
24 June 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6714589

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2021 Resolved
Fire Safety - Oil Accumulation - The purpose of this regulation is to limit the fire growth potential in every space of the ship. The following requirements shall be met: means of control for flammable liquids in the space shall be provided. PSCO observed the gathering of oil as well as non approved oil catches at; M/E booster pump, M/E Fuel Pump, abd along port side A/E Fuel Line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 8 August 2021
Resolution: Verified from class report and pictures of reapairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 24 June 2019 Resolved
The company should establish procedures, plans, instructions, including checklist. PSCO observed a block in quick closing valve. Record show C/E tested on 08JUN19. Safety management system states to test monthly. Vessel could not provide procedures for testing valve. 74 SOLAS (2009) IX/3.1, ISM Part A/7.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 15 July 2019
Resolution: Vessel submitted class report correcting defs.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 24 June 2019 Resolved
All ships 500GT and upwards shall: rudder, propeller and operational mode indicators or other means to determine and display rudder angle. PSCO observed port bridge wing indicator was displaying 5 degree difference from main conning position. 74 SOLAS (2009) V/2.5.4.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 15 July 2019
Resolution: Vessel submitted class report correcting defs.

Ownership record