Records from 2024 to 2026. Most recent: inspection, 10 April 2026.
Inspection history · 4
10 April 2026
COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8343443
3 June 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7925747
28 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7921336
10 May 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7903259
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 10 May 2024
Resolved
THE INERT GAS SYSTEM REFFERED TO IN PARAGRAPH 5.5.3.1 SHALL BE DESIGNED, CONSTRUCTED, AND TESTED IAW WITH THE FIRE SAFETY SYSTEMS CODE.PSCO OBSERVED CREW UNFAMILIAR WITH OPERATION AND TESTING OF INERT GAS GENERATOR.
74 SOLAS 09 ED II-2 4.55.3.2 50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2024
Resolved 3 June 2024
Resolution: C/E completed training with crew on IGG operation see documents for training report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 May 2024
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. [name withheld]/O LEAKING FROM M/E F/O DRAIN LINE AND SATURATED LAGING ON F/O DRAIN LINE.
74SOLAS 20ED I-11A
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2024
Resolved 10 May 2024
Resolution: CREW REPAIRED LINE AND REPLACED LAGGING
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 May 2024
Resolved
IGNITION SOURCES SHALL BE SPERATED FROM COMBUSTIBLEMATERIALS AND FLAMABLE LIQUIDS. PSCO OBSERVED STORAGE OF CARDBOARD BOXES BEHIND ECR ELECTRICAL PANEL AND IN NITROGEN GENERATOR COMPRESSOR ROOM.
74SOLAS 09ED II-2 4.1.5 40 AC
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 May 2024
Resolved 28 May 2024
Resolution: Received Class Report, deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 May 2024
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMEADIATE USE. PSCO OBSERVED HYDROSTATIC FLOAT FREE UNIT ON PORT SIDE LIFE RAFTE SET UP INCORRECTLY.
74 SOLAS 20ED III/20.2 10AC
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 10 May 2024
Resolved 10 May 2024
Resolution: VESSEL CREW INSTALLED DEVICE CORRECTLY
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 May 2024
Resolved
STAIRWAYS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY ATLEAT A-0 CLASS DIVISIONS AND BE PROTECTED BY BY SELF CLOSING DOORS AT ALL LEVELS. PSCO OBSERVED DOOR TO NAVIGATION BRIDGE NOT ABLE TO SELF CLOSE.
74 SOLAS 09ED II-2 9.2.3.4.1 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2024
Resolved 10 May 2024
Resolution: CREW REPAIRED DOOR
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2024
Resolved
FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO OBSERVED FIRE HOSE NOZZLE ON NAVIGATION BRIDGE WING NOT ABLE TO MAINTAIN PRESSURE DUE TO A BROKEN GASKET.
74SOLAS 09 11-2/14.1.1 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2024
Resolved 10 May 2024
Resolution: VESSEL CREW REPAIRED NOZZLE