← All vessels
CHEMROAD WING
CHEMROAD WING is a tank ship. The Coast Guard has recorded 4 inspections since 2024, most recently in April 2026, along with 6 deficiencies.
Records from 2024 to 2026. Most recent: inspection, 10 April 2026.
- Built
- Not recorded
- Last inspected
- 10 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9309502 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EAB8
1003456
Flag
PANAMA
—
Maury page id
psix-1003456
Inspections, by type
Years with a record
2 calendar years (2024–2026)
The 4 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it18751 - Convention (Subpart B), Gross Ton
9393 - Convention (Subpart B), Net Ton
18733 - Simplified, Gross Ton
9393 - Convention (Subpart B), Net Ton
18733 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
10 April 2026
COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8343443
3 June 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7925747
28 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7921336
10 May 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7903259
Deficiency record · 6
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 10 May 2024
Resolved
THE INERT GAS SYSTEM REFFERED TO IN PARAGRAPH 5.5.3.1 SHALL BE DESIGNED, CONSTRUCTED, AND TESTED IAW WITH THE FIRE SAFETY SYSTEMS CODE.PSCO OBSERVED CREW UNFAMILIAR WITH OPERATION AND TESTING OF INERT GAS GENERATOR.
74 SOLAS 09 ED II-2 4.55.3.2 50AC
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 May 2024
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. [name withheld]/O LEAKING FROM M/E F/O DRAIN LINE AND SATURATED LAGING ON F/O DRAIN LINE.
74SOLAS 20ED I-11A
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 May 2024
Resolved
IGNITION SOURCES SHALL BE SPERATED FROM COMBUSTIBLEMATERIALS AND FLAMABLE LIQUIDS. PSCO OBSERVED STORAGE OF CARDBOARD BOXES BEHIND ECR ELECTRICAL PANEL AND IN NITROGEN GENERATOR COMPRESSOR ROOM.
74SOLAS 09ED II-2 4.1.5 40 AC
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 May 2024
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMEADIATE USE. PSCO OBSERVED HYDROSTATIC FLOAT FREE UNIT ON PORT SIDE LIFE RAFTE SET UP INCORRECTLY.
74 SOLAS 20ED III/20.2 10AC
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 May 2024
Resolved
STAIRWAYS WHICH PENETRATE MORE THAN A SINGLE DECK SHALL BE SURROUNDED BY ATLEAT A-0 CLASS DIVISIONS AND BE PROTECTED BY BY SELF CLOSING DOORS AT ALL LEVELS. PSCO OBSERVED DOOR TO NAVIGATION BRIDGE NOT ABLE TO SELF CLOSE.
74 SOLAS 09ED II-2 9.2.3.4.1 10C
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2024
Resolved
FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO OBSERVED FIRE HOSE NOZZLE ON NAVIGATION BRIDGE WING NOT ABLE TO MAINTAIN PRESSURE DUE TO A BROKEN GASKET.
74SOLAS 09 11-2/14.1.1 10C
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.