MAURY USCG vessel records
← All vessels

KOUTALIANOS

KOUTALIANOS is a 2007 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in July 2023, along with 4 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 27 July 2023.

Built
2007
Last inspected
27 July 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 July 2023
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9332016
1003490
Flag
LIBERIA
Maury page id
psix-1003490

Documentation record

Tonnage as PSIX records it92710 - Dead Weight, Metric Ton
107968 - Displacement, Metric Ton
49973 - Convention (Subpart B), Gross Ton
30679 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

27 July 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7744405
6 June 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6969643
3 March 2020 MARPOL Annex I Examination · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6914633
25 October 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6293372
20 July 2016 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5935588

Deficiency record · 4

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2023 Resolved
The machinery, associated piping systems, and fittings shall be of a design and construction adequate for service. PSCO observed cooling water leaking from valve on M/E cylinder No. 3. 74SOLAS(04)II-1/26.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
Resolution: Tightened the bolts at cylinder head by the crews, then the cooling water was no longer leaking on MIE cylinder No.3. Visually inspected and found with satisfaction by the undersigned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2023 Resolved
The machinery, associated piping systems, and fittings shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces and other hazards. PSCO observed steam leak from No. 1 purifier heating line. 74SOLAS(04)II-1/26.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
Resolution: Tightened the leaking packing by the crews, the heating line no further steam leakage was observed. Visually inspected and found with satisfaction by the undersigned.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 July 2023 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaking from No. 3 cylinder on diesel generator No. 2. 74SOLAS(09)II-2/4.1.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
Resolution: Dismantled fuel pump cover and replaced o-rings with a new spare by the crews. The undersigned surveyor witnessed the running test with satisfactory results, no more oil leakage now.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 July 2023 Resolved
Fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occured. PSCO observed pin hole leak from CO2 line for cargo hold No. 4 starboard side. 74SOLAS(09)II-2/14.2.1.1 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 July 2023
Resolution: Dismantled the pipe with leaking hole, and replaced it with spare pipe by crew in engine work shop. Visually examined and appropriate gas tightness test found with satisfaction by the undersigned.

Ownership record