MAURY USCG vessel records Sign in
← All vessels

ONE CLARA

ONE CLARA is a 2008 freight ship. The Coast Guard has recorded 17 inspections since 2009, most recently in June 2019, along with 8 deficiencies and 2 operational controls.

Records from 2009 to 2019. Most recent: inspection, 19 June 2019.

Built
2008
Last inspected
19 June 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9355408 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1005104
Flag
SINGAPORE
—
Maury page id
psix-1005104

Inspections, by type

…with no type recorded4
Years with a record 8 calendar years (2009–2019)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it34600 - Dead Weight, Metric Ton
46000 - Displacement, Metric Ton
27051 - Convention (Subpart B), Gross Ton
11833 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

19 June 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6718888
24 April 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6669486
27 March 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6650743
29 January 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6616962
24 January 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6342784
23 January 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6075317
28 December 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6063095
30 November 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6050084
2 December 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5774187
4 November 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5757155
1 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4331583
1 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4337390
1 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4337393
29 May 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4321414
26 September 2011 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4154962
26 July 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4086493
5 May 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3467545

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 June 2019 Resolved
74 SOLAS(04) II-1/45.1.3 50ac All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Bottom of electrical control box for mooring system winch is approx. 80 percent corroded and associated grounding wire is affixed to a completely corroded part of the bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 17 July 2019
Resolution: According to Class NK Report #081191, Record #19LA0093, "A new control box was fabricated and fitted and associated grounding wire was affixed accordingly."
Construction/Loadline › Markings › Load Line Mark
Issued 28 December 2016 Resolved
Action: 40ac; Code: 1200. THE RING, LINES AND LETTERS OF THE LOAD AND DECK LINE MARKINGS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THE MARKS SHALL BE PLAINLY VISIBLE. PORT SIDE LOAD AND DECK LINE MARKS PAINT WAS RUBBED OFF AND MARKS WERE NO LONGER CLEARLY DISTINGUISHABLE FROM THE GROUND COLORS. IAW 66 ICLL (P88) REG. 8.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 January 2017
Resolution: Recieved class report with photos attesting to the proper painting of the vessels loadlines.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 4 November 2015 Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement. All four liferafts, 2 port and 2 stbd, were oncorrectly installed to inhibit the float-free arrangement for each inflatable liferaft. IAW 74 SOLAS (2009) Ch III/13.4.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2015
Resolution: Vessel modified existing liferaft arrangement, port and stbd side, ensured separate float-free arrangements.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 4 November 2015 Resolved
Where "A" class divisions are penetrated....penetrations shall be suitable insulated by extension of the insulation at the same level of the division. Found insufficient insulation in multi-deck cable trunk room, in an "A" class fire boundary. IAW 75 SOLAS (2004) Ch II-2/9.3.1 (40ac)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2015
Resolution: Insulation and proper sealing compound were installed.
Lifesaving › Lifebuoys › Serviceable
Issued 4 November 2015 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Both (02) lifebuoys on the bridge were found deteriorated with hole punctures. IAW 74 SOLAS (2009) Ch III/20.2 (40ac)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2015
Resolution: Replaced damaged lifebuoys with new lifebuoys.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 November 2015 Resolved
All electrical apparatuses shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Found exposed portions on several junction boxes in the bosun locker. IAW 74 SOLAS (2004) ChII-1/45.1.3 (40ac)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2015
Resolution: Properly sealed and insulated junction boxes in Bosun store.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 4 November 2015 Resolved
Waste receptacles shall be constructed of non-combustible materials. Food waste containers are made of plastic. IAW 74 SOLAS (2004) Ch II-2/4.4.2 (40ac)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2015
Resolution: Plastic waste receptacles have been replaced with non-combustible receptacles.
Documentation › Certificates/Documents › IOPP Certificate
Issued 26 July 2011 Resolved
CODE: 0150 DESCRIPTION: THE IOPPC SHALL BE DRAWN UP IN THE FORM CORRESPONDING TO THE MODEL GIVEN IN MARPOL ANNEX I/APPENDIX II. THE IOPPC ONBOARD HAS NOT BEEN UPDATED IN ACCORDANCE WITH MEPC 187(59). *Deficiency to remain open until next scheduled IOPP survey. CITE: MARPOL 2006 ANNEX I/REG 9
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2011
Resolved 26 September 2011
Resolution: Class survey indicates new IOPP Certificate issued to the vessel, and is now in compliance with MEPC 187(59).

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.