Records from 2009 to 2021. Most recent: inspection, 28 September 2021.
Documentation record
Tonnage as PSIX records it9927 - Dead Weight, Metric Ton
15256 - Displacement, Metric Ton
9735 - Regulatory (Subpart C or D), Gross Ton
9735 - Convention (Subpart B), Gross Ton
2920 - Regulatory (Subpart C or D), Net Ton
2920 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
28 September 2021
COC-GAS Renew · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7314584
22 June 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6983619
16 June 2020
Administrative Inspection · COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6978555
12 May 2014
ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4853635
30 May 2012
COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4328402
17 January 2012
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4221484
15 December 2011
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 4209595
26 January 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3933891
2 March 2010
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 3689199
10 May 2009
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3471331
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 September 2021
Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCOS OBSERVED 04 HOSES ON THE CO2 CYLINDER SYSTEM THAT EXHIBITED SIGNIFICANT DETERIORATION WHICH EXPOSED THE INNER METALLIC CORE OF THE HOSES.
(74SOLAS(20) II-2/14.2.1.2)
ACTION CODE: 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2021
Resolved 4 October 2021
Resolution: Class report recieved. All sat, deficiency cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 September 2021
Resolved
IN REGARDS TO THE LOAD LINE MARK, THE RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL ALSO BE PERMANENTLY MARKED ON THE SIDES OF THE SHIPS TO THE SATISFACTION OF THE ADMINISTRATION. PSCOS OBSERVED THAT THE PLIMSOLL MARK, WHILE PAINTED, WAS NOT PERMANENTLY MARKED.
(ICLL(88)I/8) ACTION CODE: 40bc.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 October 2021
Resolution: Flag surveyor provided documentation showing completed etching/punch marks on the Load Line. See documents section.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 September 2021
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCOS UNABLE TO WITNESS SATISFACTORY TEST OF RESCUE BOAT ENGINE. ALLOWED CREW UNTIL END OF PSC EXAM TO CORRECT ISSUE. PSCOS WITNESSED SATISFACTORY RESUCE BOAT OPERATIONAL TEST.
(74SOLAS(20)III/20.2)
ACTION CODE: 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 September 2021
Resolution: Deficiency corrected prior to PSCOs departing vessel.
Construction/Loadline › Markings › Load Line Mark
Issued 12 May 2014
Resolved
Loadline freshwater mark is not permanently affixed to the vessel on the port side IAW ILLC Ch I Reg 9.
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 19 May 2014
Resolution: Received Class report attesting to satisfactory repairs.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 12 May 2014
Resolved
Deck waterspray system was not providing coverage at the port manifold IAW IGC Code 11.
Due 12 May 2014
Resolved 12 May 2014
Resolution: Nozzles were replaced and proper coverage was maintained.
Construction/Loadline › Markings › Load Line Mark
Issued 4 June 2012
Resolved
Vessels Loadline mark does not match the one illustrated on the corresponding Loadline certificate. The Loadline is not permanently affixed to the vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 June 2012
Resolution: Recieved Class Survey stating the plimsoll mark has been repainted by the crew. A hull recommendation was issued to permanently affix the Loadline mark by punch or welding by 30 October 2013.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 January 2012
Resolved
X-Band Radar not working properly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2012
Resolved 17 January 2012
Resolution: Recieved Tech report from [name withheld] stating that they repaired X-Band Radar and conducted satisfactory system test.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 May 2009
Resolved
Self shutting fire doors for air lock into motor room were not fitted with self closing mechanisms
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 September 2009
Resolution: CLass report recieved attesting to proper repairs.