← All vessels
HYUNDAI SHANGHAI
HYUNDAI SHANGHAI is a 2005 freight ship. The Coast Guard has recorded 21 inspections since 2009, most recently in October 2024, along with 12 deficiencies and 3 operational controls.
Records from 2009 to 2024. Most recent: inspection, 30 October 2024.
- Built
- 2005
- Last inspected
- 30 October 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9305647 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5BZM3
1006474
Flag
CYPRUS
—
Maury page id
psix-1006474
Inspections, by type
…with no type recorded7
Years with a record
11 calendar years (2009–2024)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it80102 - Dead Weight, Metric Ton
107492 - Displacement, Metric Ton
74651 - Convention (Subpart B), Gross Ton
43151 - Convention (Subpart B), Net Ton
107492 - Displacement, Metric Ton
74651 - Convention (Subpart B), Gross Ton
43151 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
30 October 2024
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8026991
4 June 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7215704
21 April 2021
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7179783
4 March 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7150456
14 February 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6909201
12 August 2019
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6781017
15 March 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6644120
29 November 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6589092
2 November 2017
PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6299209
13 October 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6021696
26 July 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5953549
26 July 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5960296
22 September 2015
PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5725119
8 May 2014
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4849051
28 March 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4824801
8 March 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4812353
5 March 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4805582
7 February 2012
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4239458
13 May 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3471555
13 May 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3473258
13 May 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3473876
Deficiency record · 12
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 February 2020
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. Fuel oil leaks were found throughout the purifier room. The fuel oil leaks have caused fuel oil to accumulate, presenting a fire hazard.
Action: 16a Code: 07126 Cite: 74Solas(04)II-2/4.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2019
Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED 04 SOFT PATCHES ON THE BALLAST STRIPPING EDUCTOR.
74SOLAS 2004 CONSOLIDATED II-1/26.1
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 29 November 2018
Resolved
MARPOL I/14.6
MEPC.107(49)4.2.10.2
OIL FILTERING EQUIPMENT SHALL BE PROVIDED WITH ALARM ARRANGEMENTS TO INDICATE WHEN THIS LEVEL CANNOT BE MAINTAINED. THE SYSTEM SHALL ALSO BE PROVIDED WITH ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15 PPM. IN CONSIDERING THE DESIGN OF SUCH EQUIPMENT AND APPROVALS, THE ADMINISTRATION SHALL HAVE REGARD TO THE SPECIFICATION RECOMMENDED BY THE ORGANIZATION. TO AVOID WILFUL MANIPULATION OF THE 15 PPM BILGE ALARMS, THE 15 PPM BILGE ALARM SHOULD BE SO CONSTRUCTED THAT THE ALARM IS ALWAYS ACTIVATED WHENEVER CLEAN WATER IS USED FOR CLEANING OR ZEROING PURPOSES. WHILE CONDUCTING THE SIMULATION TEST FOR THE 107 OIL CONTENT METER, THE OPERATIONAL TEST OF THE 15 PPM ALARM, AND FUNCTION OF THE 3 WAY OVERBOARD VALVE, PSCO IDENTIFIED THE UNRELIABILITY OF THE OIL CONENT METER (OCM), FRESH WATER FLUSH VALVE/CONTROL, AND 3 WAY OVERBOARD VALVE. WITH THE OCM IN A "OK" STATUS, THE 2ND ENGINEER SHIFTED THE FRESH WATER FLUSH VALVE TO FLUSH. THE OCM STAYED IN A "OK" STATUS AND THE OCM DISPLAY FROZE WITH 5 PPM ON THE SCREEN AND NO ALARM WAS RECEIVED ON THE OCM. THE OVERBOARD VALVE DID NOT CHANGE STATE AND REMAINED IN THE CLOSED POSITION. THE 2ND ENGINEER THEN SHIFTED THE FRESH WATER FLUSH VALVE TO NORMAL OPERATION AND THE OVERBOARD VALVE REMAINED IN THE CLOSED POSITION WITH A "OK" STATUS AND NO ALARMS ON THE OCM.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2018
Resolved
74 SOLAS (2014) I/11(a)
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO IDENTIFIED SALT WATER LEAKS ON THE OUTLET PIPE FLANGES FOR BOTH THE #1 & #2 ENGINE COOLERS.
Engineering › Fuel Oil Service System › Hose
Issued 2 November 2017
Resolved
code: 0750: IN A SHIP IN WHICH FUEL OIL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. HIGH PRESSURE FUEL LINES AND O-RINGS ON THE MAIN ENGINE WERE FOUND LEAKING. PURIFIER FEED PUMP FOUND LEAKING IN PURIFIER ROOM. OIL SOAKED LAGGING FOUND IN CONJUNCTION WITH LEAKS ON SHOP SERVICE GENERATORS AND IN PURIFIER ROOM. solas 74(2014 CONS.) CH II-2 REG 4.2.2
Engineering › Steering Gear System › Power Unit
Issued 2 November 2017
Resolved
CODE: 0936 WHERE THE MAIN STEERING GEAR COMPRISES TWO OR MORE IDENTICAL POWER UNITS, AN AUXILIARY STEERING GEAR NEED NOT BE FITTED, PROVIDED THAT IN A CARGO SHIP, THE MAIN STEERING GEAR IS CAPABLE OF OPERATING THE RUDDER AS REQUIRED BY PARAGRAPH 3.2 WHILE OPERATING WITH ALL POWER UNITS. THE NUMBER THREE STEERING GEAR PUMP WOULD NOT RESPOND TO COMMANDS. SOLAS 74 (2014 CONS.) CH II-1 REG 29.6.1.2 40AC ISSUED.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Blower, Centrifugal
Issued 26 July 2016
Resolved
When the vessel was inbound to Tacoma, WA they had a blower trip when increasing rpm and subsequently had a loss of power for approximately 1 minute.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 March 2014
Resolved
On March 1, 2014, M/V HYUNDAY SHANGHAI transited through the Western Alaska Captain of the Port zone while enroute to a U.S. port without a valid Geographic Specific Appendix for Western Alaska in its non-tank vessel response plan.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 March 2014
Resolved
1570- Nautical publications -Nautical publications and nautical charts necessary for the intended voyage shall be adequate and up to date. The vessel's sailing directions for Puget Sound and British Colombia were not up to date.
74SOLAS (2009 Cons.) Ch. V Reg. 27
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 March 2014
Resolved
Abandon Ship drill was not conducted due to bunkering. An abandon ship table top exercise was conducted.
Operations/Management › Drills/Instruction › Fire
Issued 5 March 2014
Resolved
Fire drill was not conducted due to bunkering. A fire drill table top exercise was conducted.
Lifesaving › Launching Appliances › Davit
Issued 5 March 2014
Resolved
Lifeboat was not able to be lowered due to bunkering operations waterside.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.