MAURY USCG vessel records Sign in
← All vessels

IOLE R

IOLE R is a 2008 freight ship. The Coast Guard has recorded 11 inspections since 2010, most recently in February 2023, along with 11 deficiencies and 2 operational controls.

Records from 2010 to 2023. Most recent: operational control imposed, 7 February 2023.

Built
2008
Last inspected
7 February 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9363132 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2610
1007131
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1007131

Inspections, by type

Years with a record 7 calendar years (2010–2023)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it95905 - Displacement, Ton
83684 - Dead Weight, Ton
44146 - Convention (Subpart B), Gross Ton
27058 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

7 February 2023 PSC B · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7624478
7 February 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7633667
27 September 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7066303
13 March 2020 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6919932
26 February 2020 Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6903951
18 October 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6284218
10 February 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5805985
21 May 2012 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4309144
5 July 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4060906
18 February 2010 Ballast Water Examination · Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3679201
12 February 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3679443

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 February 2023 Resolved
Ships shall be provided with independently driven fire pumps as follows: in cargo ships of 1000 GT and upwards - at least two. PSCO observed the #2 fire pump leaking a steady stream of water. 74 SOLAS (a) 2004 cons. II-2/10.2.2.2.2 Code: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2023
Resolution: Received LR class report: pump gland seal packing was replaced
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil/water interface detector
Issued 9 February 2023 Resolved
The accuracy of the 15 PPM bilge alarms should be checked at IOPP certificate renewal surveys according to the manufacturers instructions. Alternatively the unit may be replaced by a calibrated 15 PPM bilge alarm. The calibration certificate for the 15 PPM bilge alarm, certifying date of last calibration check, should be retained on board for inspection purposes. The calibration certificate for the 15 PPM bilge alarm observed by the PSCO did not match the installed serial number on the 15 PPM bilge alarm. Provide accurate calibration certificate. MARPOL ANNEX I/14.7 MEPC 107(49) 4.2.11 CODE: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2023
Resolution: Received LR class report: attested serial #'s matched.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 February 2020 Resolved
All access openings in the bulkheads at ends of enclosed superstructure shall be fitted with doors of steel or other equivalent materials, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. PSCO observed exterior door leading to aft steering allowing light to come past seal when dogged. PSCO also observed evidence of water intrusion in the form of rust around the bottom of the emergency generator room door. Additionally, the dogs would not dog properly and light was observed coming through. ILCC 12.1 50abc
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2020
Resolved 13 March 2020
Resolution: Exterior hatch leading to aft steering gear room and hatch leading to generator room satisfactorily repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2020 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed exposed wires on M/E LO Purifer. 74SOLAS (04)II-1/45.1.3 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 February 2020
Resolved 26 February 2020
Lifesaving › Lifeboat Equipment › Food Ration
Issued 10 February 2016 Resolved
0611- Lifeboat Inventory. Every lifeboat shall have a food ration totalling not less than 10,000 kj for each person the lifeboat is permitted to accomodate. PSCO observed 25 person free fall lifeboat only contains food for 13 people. 74 SOLAS AM III/34; LSA Code 4.4.8
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2016
Resolved 12 February 2016
Resolution: Classification society NKK provided reciept for the purchase of additional food for the life boat and provided photographs of the food upon arrival as proof of delivery. Vessle now has 25 packages of food.
Documentation › Logs/Records › Oil Record Book
Issued 21 May 2012 Resolved
VESSEL OIL RECORD BOOK (ORB) PART ONE (1) HAS SOME INCONSISTENT ENTRIES. AN EXPANDED MARPOL EXAM WAS CONDUCTED WITH SATISFACTORY RESULTS. THE DISCHARGE PIPE ON THE OWS WAS CRACK AND FOUND CLEAN. AN OPERATIONAL TEST OF OWS WAS SATISFACTORY. TWO ORB ENTRIES SHOWED THE OWS TO BE OPERATED ABOVE RATED THROUGHPUT, AND SOME MATHEMATICAL ERRORS. HOWEVER IS IT NOT BELIEVED THAT ANY OTHER ISSUES EXIST.
Due 21 May 2012
Resolved 21 May 2012
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 21 May 2012 Resolved
STEERING ON FREEFALL LIFEBOAT IS INOPERABLE. VESSEL MUST MAKE REPAIRS TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY SURVEYOR PRIOR TO DEPARTURE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2012
Resolution: RECIEVED CLASS REPORT ATTESTING TO SATISFACTORY REPAIRS.
Lifesaving › Launching Appliances › Release Mechanism
Issued 5 July 2011 Resolved
0630 - Launch arrangt. for survival craft - All life-saving appliances shall be in working order and ready for immediate use. Port life raft was tied to bracket and stbd float free arrangt rigged to render life raft inop. SOLAS lifesaving checklists showed inspections occurred since crew says they lashed raft or heavy weather. Maintenance records don't reflect actual condition. - SOLAS 74a III/20.
Action required: 705 - Other - as specified
Due 5 July 2011
Resolved 6 July 2011
Resolution: Received class report from NKK satisfying requirement. Report stated the lashing was removed from the Port Side Liferaft, and both Liferafts were found to be properly stowed and rigged for float-free deployment.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 5 July 2011 Resolved
9900 - Other (not clearly hazardous) - Each commercial vessel 79 feet and longer in US waters are required to have a Vessel General Permit and conduct weekly, quarterly, and annual inspections. Vessel does not have VGP onboard, and has not conducted required inspections. Rectify immediately. - 40 CFR 122.2. Sector New Orleans Port State Control. [email withheld]
Action required: 705 - Other - as specified
Due 5 July 2011
Resolved 7 July 2011
Resolution: Received verification from master that the VGP is onboard, and a copy of a completed weekly inspection.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 5 July 2011 Resolved
0899 - Other (acid. prevention) - Each oil transfer system must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel could not provide proof of hydrostatic test to 1.5 times MAWP. Correct prior to transfer in United States - 33 CFR 156.170
Action required: 703 - Prior to bunkering operations
Resolved 6 July 2011
Resolution: Vessel provided proof of satisfactory hydrostatic tests.
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 18 February 2010 Resolved
1699-(Other Radio) The PSCO observed on the Safety Equipment Certificate that the LRIT system has been fitted. Master was unable to provide the conformance test report for the LRIT. Master did however provided a copy of the class survey report from NKK classification society stating that the LRIT conformance test had been issued on 10th July 2009 by ASP. SOLAS 2004 cons V/19
Due 4 March 2010
Resolved 19 February 2010
Resolution: Received and reviewed LRIT conformance test report sent by the Master of the vessel. Deficiency has been rectified.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.