MAURY USCG vessel records
← All vessels

CMA CGM SURABAYA

CMA CGM SURABAYA is a 2007 freight ship. The Coast Guard has recorded 20 inspections since 2022, most recently in July 2026, along with 3 deficiencies and 11 operational controls, 1 with no removal date recorded.

Records from 2022 to 2026. Most recent: operational control imposed, 17 July 2026.

Built
2007
Last inspected
17 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 July 2026
…with no type recorded12
Operational controls 1 with no removal date recorded
Years with a record 5 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9412830
9HA5723
1007176
Flag
MALTA
Maury page id
psix-1007176

Documentation record

Tonnage as PSIX records it21470 - Dead Weight, Ton
17294 - Convention (Subpart B), Gross Ton
7814 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

17 July 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8440618
14 June 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8404282
27 May 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8381929
11 May 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8370625
9 May 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8369677
24 April 2026 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8355267
24 November 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8273420
22 November 2025 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8272563
31 October 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8261439
29 October 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8260306
15 October 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8019248
23 September 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8007896
13 August 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7979799
10 August 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7978228
8 February 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7862470
31 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7757127
24 July 2023 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7749525
12 July 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7740714
20 June 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7718758
15 December 2022 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7609205

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 May 2026 Resolved
"The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs:... fire detection and fire alarm systems." / PSCO observed 01 inoperable flame detector above the fuel oil purifier space. 74SOLAS(09) II-2/14.2.1.1.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2026
Resolved 11 May 2026
Resolution: Flame detector was replaced and tested satisfactory during exam.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2026 Resolved
"Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power." /PSCO observed inadequate lighting at both embarkation stations. 74SOLAS(20) III/ 11.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2026
Resolved 11 May 2026
Resolution: Witnessed replacement of the Emergency lighting during the exam.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 15 December 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While examining the engine room, PSCO noticed a water stream coming out of the ballast water pump flange. The C/E explained the ballast water pump relies on packing material to maintain a eal and cool the motor. To rectificy the issue, additional packing material was added to the seal stopping the leak completely.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 15 December 2022
Resolved 15 December 2022
Resolution: Additional packing was added to the ballast water pump which stopped the leak.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.