CHAMPION POLAR is a 2006 tank ship. The Coast Guard has recorded 18 inspections since 2016, most recently in June 2026, along with 12 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 15 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13081 - Convention (Subpart B), Net Ton 47834 - Dead Weight, Metric Ton 57472 - Displacement, Metric Ton 27916 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
15 June 2026Ballast Water Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8405406
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 6 November 2025Resolved
An immersion suit of an appropriate size complying with the requirements of section 2.3 of the code shall be provided for every person onboard the ship. PSCO observed incorrect sizing of immersion suits for the crew.
74 SOLAS III
32.3.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2025
Resolution: Received, reviewed and accepted proper documentation from master stating the deficiency was rectified. Vessel ordered new immersion suits.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 November 2025Resolved
Paint locker shall be protected by a water spraying or sprinkler system. PSCO observed incorrect heads on sprinkler system in ppaint locker.
74 SOLAS II-2
10.6.3.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2025
Resolved 11 November 2025
Resolution: Received, reviewed proper documentation from vessel stating the deficiency was rectified. Vessel sent in documention of new valve heads and pictures of them.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 November 2025Resolved
In tankers, isolation valves shall be fitted in the fire main at the poop front in a protected position and on the tank deck at intervals of not more than 40m to preserve the integrity of the main system in case of fire or explosion. PSCO observed that 02 isolation valves did not function. Rectify prior to loading flammable cargo.
74 Solas II-2
10.2.1.4.4
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2026
Resolution: VESSEL CLEARED TO THE SATISFACTION OF THE USCG-FORM B UPLOADED TO MISSLE
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 November 2025Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or the persons onboard. PSCO observed that the fixed gas detection was not detecting the correct LEL for the supplied test gas.
74 SOLAS I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 November 2025
Resolution: Received, reviewed and accepted class report / proper documentation from Class report stating the deficiency was rectified. Correct fixed Gas LEL test gas supplied.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 November 2025Resolved
The company shall comply with requirements fo the ISM code. The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The operational nature of the deficiency 05 provides objective evidence of a failure in the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted within 90 days. PSCO observed that the crew does not have procedures for calibrating and testing the fixed gas monitoring system.
74 SOLAS IV/3.1
ISM Code 10.1
Action required: 705 - Other - as specified
Due 4 February 2026
Resolved 10 June 2026
Resolution: DEFICIENCY CLEARED BY USCG-FORM B UPLOADED TO MISSLE
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 8 March 2025Resolved
The IG system shall be capable of the delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. Fixed oxygen analyzer for IGG found inoperable due to previous flooding event of IGG lines, including sensor lines. At the time of the exam vessel was discharging cargo with an electronic bypass on the oxygen sensor and IGG panel, as well as using a portable gas meter for oxygen sampling. Deficiency is required to be rectified prior to cargo operations.
74 SOLAS (2004 Cons.) II-2/4.5.5.1.1 & FSS Code 15.2.2.1.2.5
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2025
Resolved 10 March 2025
Resolution: Received satisfactory class report, see attached. Vessel replaced oxygen sensor with new fixed system. PSCO attended, O2 sensor calibrated and tested by running IGG, all sat.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 8 March 2025Resolved
The inert gas system shall be designed, constructed and tested to the satisfaction of the Administration. IGG system experienced flooding of the scrubber, blowers, and oxygen analyzing lines due to a shutdown caused by a failure of the cargo pump power pack system. Deficiency required to be rectified prior to cargo operations.
74 SOLAS (2004 Cons.) II-2/4.5.5.1.1 & FSS Code 15.2.2.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2025
Resolved 10 March 2025
Resolution: Received satisfactory class report, see attached. PSCO attended and conducted tests of IGG, all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 March 2025Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. No.1 power pack tripped and caused a shutdown of the cargo pump system due to a zero insulation alarm and preferential trip. Deficiency required to be rectified prior to cargo operations.
74 SOLAS (2020 Cons.) II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2025
Resolved 10 March 2025
Resolution: Received satisfactory class report, see attached. PSCO attended to conduct tests, cargo pump system ran on no.1 power pack. Emergency shutdowns tested, all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 March 2025Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. Cargo monitoring system panel found with ongoing alarm condition and erroneous value due to inoperable forward draft sensor in fore peak tank.
74 SOLAS (2020 Cons.) II-1/3-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2025
Resolved 15 April 2025
Resolution: Received satisfactory class report, see attached. Deficiency extended to 30 days to coincide with condition of class. UMS designation removed, new class cert issued by LR.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 8 March 2025Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. The hydrogen sensor on the starboard BWMS venting arrangement is broken off from permenant installation, leaving wires unshielded.
33 CFR 151.2025(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2025
Resolved 15 April 2025
Resolution: Received satisfactory class report, see attached. Deficiency extended to coincide with condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 March 2023Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. SHIP'S MAIN ENGINE GOVERNOR IS INOPERABLE. MAIN ENGINE CONTROL FROM BRIDGE INOPERABLE. SOLAS 74(2020 CONS.) 1/11
Action required: 60 - Rectify deficiencies prior to movement
Due 9 March 2023
Resolved 9 March 2023
Resolution: Vessel submitted Class Report attesting to replacement of electronic block inside engine control console and successful testing of engine.
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2022
Resolution: Vessel provided technician report from PRAXIS confirming the sat operations of the BWMS. Replaced the sensor adapters for channels 31811 (CPP Remote Sept. A-In). Testing is sat.