MAURY USCG vessel records
← All vessels

ATHINA

ATHINA is a 2008 tank ship. The Coast Guard has recorded 1 inspection in 2016, along with 2 deficiencies.

Records in 2016. Most recent: inspection, 9 March 2016.

Built
2008
Last inspected
9 March 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 March 2016
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9389564
1008460
Flag
LIBERIA
Maury page id
psix-1008460

Documentation record

Tonnage as PSIX records it21943 - Convention (Subpart B), Net Ton
74999 - Dead Weight, Metric Ton
88827 - Displacement, Metric Ton
42331 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

9 March 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5826264

Deficiency record · 2

Deck/Cargo › Inert Gas System › Flue Gas Isolating Valve
Issued 9 March 2016 Resolved
0750- Fire Prevention- Tankers operating with a cargo tank cleaning procedure using crude oil washing shall be fitted with an inert gas system complying with the Fire Safety System Code. PSCO observed the inert gas systems's oxygen analyzer was inoperable and PSCO was unable to prove proper operation of the inert gas system. SOLAS 74(am) II-2/4.5.5.1.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2016
Resolved 9 March 2016
Resolution: Electrical short was found in oxygen analyzer caused by condensation dripping on electrical box. Affected parts were replaces and system was successfully calibrated and tested.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 9 March 2016 Resolved
0750- Fire Prevention- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed two temperature sensing devices that were improperly installed on the #1 and #2 ballast water pumps- SOLAS 74(am) I/11a - 10c
Condition: Improper/Lack of Maintenance
Due 16 March 2016
Resolved 9 March 2016
Resolution: Temperature sensing devices were reinstalled properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.