This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it21943 - Convention (Subpart B), Net Ton 74999 - Dead Weight, Metric Ton 88827 - Displacement, Metric Ton 42331 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 1
9 March 2016COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5826264
Deck/Cargo › Inert Gas System › Flue Gas Isolating Valve
Issued 9 March 2016Resolved
0750- Fire Prevention- Tankers operating with a cargo tank cleaning procedure using crude oil washing shall be fitted with an inert gas system complying with the Fire Safety System Code. PSCO observed the inert gas systems's oxygen analyzer was inoperable and PSCO was unable to prove proper operation of the inert gas system. SOLAS 74(am) II-2/4.5.5.1.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2016
Resolved 9 March 2016
Resolution: Electrical short was found in oxygen analyzer caused by condensation dripping on electrical box. Affected parts were replaces and system was successfully calibrated and tested.
0750- Fire Prevention- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed two temperature sensing devices that were improperly installed on the #1 and #2 ballast water pumps- SOLAS 74(am) I/11a - 10c
Condition: Improper/Lack of Maintenance
Due 16 March 2016
Resolved 9 March 2016
Resolution: Temperature sensing devices were reinstalled properly.