MAURY USCG vessel records Sign in
← All vessels

GANSETT

GANSETT is a 1969 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1984, most recently in April 2026, along with 49 deficiencies.

Records from 1984 to 2026. Most recent: inspection, 17 April 2026.

Built
1969
Last inspected
17 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI3751
100928
Flag
UNITED STATES
368256810
Maury page id
psix-100928

Inspections, by type

…with no type recorded4
Years with a record 35 calendar years (1984–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.5 ft × 5.3 ft
Registered tonnagegross 22 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEAL & BUNKDER · CRANBERRY ISLE, ME, UNITED STATES · built 1969
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM9884MMSI 368256810 · active · compulsorily equipped · granted 18 May 2022, expires 18 May 2032
WDI3751MMSI 367691530 · expired · compulsorily equipped · granted 12 September 2015, cancelled 7 March 2026
WDC5548MMSI 367042760 · expired · compulsorily equipped · granted 17 May 2005, cancelled 18 July 2015
WDA5054MMSI 369013000 · expired · compulsorily equipped · granted 20 June 2001, cancelled 20 August 2011 · licensed under a name not among this hull’s recorded names (not shown)
WBV8230MMSI not assigned · expired · compulsorily equipped · granted 13 July 1998, cancelled 13 September 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCW7091MMSI not assigned · expired · compulsorily equipped · granted 1 July 1996, cancelled 2 September 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 64

17 April 2026 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8351591
24 July 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8192603
28 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8096199
23 July 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7946295
30 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7686940
10 April 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7658189
23 May 2022 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7444037
4 May 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7443849
7 September 2021 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7289009
19 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7157032
8 September 2020 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7047423
9 September 2019 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6807641
8 July 2019 Administrative Inspection · Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6742113
28 February 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6627972
11 September 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6534737
8 June 2017 Internal Structural Exam · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6161691
27 April 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6124519
6 September 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5987366
5 May 2016 Construction Oversight · Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5869798
4 September 2015 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5231412
24 May 2012 DAPI Audit · COI Inspection · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4320852
7 September 2010 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3838558
14 May 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3467053
29 May 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3210779
2 April 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2901574
11 January 2006 Construction Oversight · Initial Certification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2621219
9 February 2005 Construction Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2471183
7 August 2000 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1453789
29 June 2000 COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1412148
20 June 2000 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1365829
22 November 1999 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 810307
6 July 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1087478
21 September 1998 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 799180
17 March 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 774087
10 September 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 786618
27 September 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142681
16 September 1996 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268479
13 August 1996 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1090281
28 June 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1192218
19 October 1995 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1411183
22 September 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877300
26 August 1995 Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 878889
25 August 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 61498
23 May 1995 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875469
25 May 1994 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860777
12 May 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169601
19 October 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 827363
23 September 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1151922
5 August 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1153454
27 July 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1156977
23 November 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1136941
9 October 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957255
23 September 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 937167
2 October 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 934204
14 August 1991 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1251467
2 October 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 901185
4 September 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1237053
22 September 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1329714
7 August 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1349345
13 July 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 897990
15 September 1987 Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1009969
18 July 1986 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 994341
10 March 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1301814
18 October 1984 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 981942

Deficiency record · 49

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel is missing 1 of the 3 fire buckets and a lanyard must be placed on all 3 fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 7 August 2024
Resolution: 3 new fire buckets have been added with attached lanyards.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 July 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Place a current chart on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 7 August 2024
Resolution: New chart placed on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 July 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The analgesic medication was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 7 August 2024
Resolution: New bottle of aspirin added to first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 July 2024 Resolved
At each subsequent inspection for certification, the MI shall view the vessel afloat and conduct inspections of the hull structure and its appurtenances. 01 frame located on the stbd side mid section adjacent to the engine is cracked. Repair/replace during next drydock. OLD 46 CFR 176.25-5(a)
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 9 April 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2023 Resolved
FCC Radiosafety Cert expired. Renew. 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 11 June 2023
Resolution: Certs renewed
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 30 May 2023 Resolved
VHF radio is not set up for DSC. Properly set up in conjunction with GPS system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 7 July 2023
Resolution: DSC installed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 September 2020 Resolved
At each subsequent inspection for certification, the MI shall view the vessel afloat and conduct inspections of the hull structure and its appurtenances. 01 frame located midsection outboard of port batteries is cracked. Repair/replace during next drydock. 46 CFR 176.25-5(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 March 2021
Resolution: Repaired using 16.5" scarfed in piece of oak, fastened using silicon bronze screws and Gflex epoxy. Screws and wood replaced in-kind.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 September 2019 Resolved
Prove proper operation of bilge system alarms audible and visual.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2019
Resolved 3 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 September 2019 Resolved
Properly label bilge alarms, nav lights, and all electrical switches on the console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2019
Resolved 3 October 2019
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 September 2016 Resolved
Out of service / maintenance
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 16 September 2016
Resolution: New extinguisher installed on vessel.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 September 2015 Resolved
Provide current COD.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 1 October 2015
Documentation › Certificates/Documents › FCC SSL
Issued 4 September 2015 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 1 October 2015
Fire Fighting › Ventilation Systems › Ducts
Issued 4 September 2015 Resolved
Provide means to secure vent stbd side 2nd deck for engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 1 October 2015
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 May 2012 Resolved
Provide an updated FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 19 June 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2012 Resolved
Provide an eye wash kit for the first aid kit.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 19 June 2012
Documentation › Markings/Placards › Warning Signs
Issued 24 May 2012 Resolved
Post the emergency broadcast placard.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 19 June 2012
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 September 2010 Resolved
Provide proof of drug testing program. Consortium cert and verification form.
Action required: 705 - Other - as specified
Due 14 September 2010
Resolved 10 September 2010
Resolution: Received fax of certificate of enrolment and verification form from Newport Hospital Occupational Health Services.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 September 2010 Resolved
Provide proof of crew training and drills.
Action required: 705 - Other - as specified
Due 14 September 2010
Resolved 24 September 2010
Resolution: Log of training and drills was on board and reviewed.
Engineering › Bilge Water Management System › Valve
Issued 7 September 2010 Resolved
Prove proper operation of bilge manifold valve for engine room pick up.
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 24 September 2010
Resolution: Handle was installed on valve and tested.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 May 2007 Resolved
Provide current up to date chart for all areas allowed on COI.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: On demand charts observed on board vsl.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 May 2007 Resolved
Complete proper installation of 2 courtesy lights on port side underneath fixed seating.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: Courtesy lights observed to be installed iaw manufacturers specs.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 May 2007 Resolved
Properly install proper bell mount.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: Proper bell mount witnessed to be installed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 30 May 2007 Resolved
Label breaker panel for 3 mislabeled markings as discussed.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: Breaker panel witnessed to be appropriately labeled.
Electrical
Issued 29 June 2000 Resolved
BLANK OFF OPENINGS IN ELECTRICAL DISTRIBUTION PANEL.
Condition: Unknown
Due 7 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 29 June 2000 Resolved
INSTALL A HIGH LEVEL BILGE ALARM IN THE FORWARD COMPARTMENT.
Condition: Unknown
Due 7 July 2000
Resolved 28 July 2000
Documentation
Issued 29 June 2000 Resolved
VESSEL LIMITED TO NOT MORE THAN 1,000 FEET FROM SHORE UNTIL A VALID RADIOTELEPHONY SAFETY CERTIFICATE IS ON BOARD.
Condition: Unknown
Due 7 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 29 June 2000 Resolved
REMOVE ALL RUBBER HOSES FROM THE BILGE/FIRE SYSTEM.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Lifesaving
Issued 16 September 1996 Resolved
INSTALL DISCONNECT CLIP ON RING BUOY FLOATLIGHT LANYARD.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996 Resolved
PROVIDE BRIGHTLY COLORED, PROPERLY LABELED CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996 Resolved
POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996 Resolved
PROVIDE GUARD OVER POWER TAKE OFF PULLEY FOR FIRE PUMP.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996 Resolved
APPLY RETROREFLECTIVE TAPE TO RING BUOY.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Fire Fighting
Issued 22 September 1995 Resolved
PORTABLE FIRE EXTINGUISHER LOCATED IN FORWARD CABIN NOT PROPERLY MOUNTED. PROVIDE PROPER MOUNTING BRACKET IN ACCORDANCE WITH EXTINGUISHER APPROVAL._x001C_
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Lifesaving
Issued 22 September 1995 Resolved
APPROXIMATELY 31 LIFEPRESEVERS SINGLE STITCHED IN SHOULDER AREA. BRING LIFE PRESERVERS INTO COMPLIANCE WITH 46CFR160. APPROVAL
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Lifesaving
Issued 22 September 1995 Resolved
SEVEN (7) PERSON BOUYANT APPARATUS FADED AND DISCOLORED. BRING BUOYANT APPARATUS INTO COMPLIANCE WITH APPROVAL.
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Accommodation/Occupational Safety
Issued 22 September 1995 Resolved
PROVIDE PROPER RAILS AND GUARDS FOR FORDECK AND BRING INTO COMPLIANCE WITH 46CFR177.35
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Construction/Loadline
Issued 26 August 1995 Resolved
COMPLETE PERMANENT REPAIRS TO FRACTURED TRANSOM PLANKING TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR ON OR BEFORE NEXT SCHEDULED DRYDOCK 30 NOV 95.
Condition: Unknown
Due 26 August 1995
Resolved 26 August 1995
Construction/Loadline
Issued 12 May 1994 Resolved
REFASTEN PLANK ENDS BOTH PORT AND STARBOARD AT SHAFT LOG FROM GARBOARD PLANK UP TO TURN OF BILGE. _x001C_ _x001C_
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Deck/Cargo
Issued 12 May 1994 Resolved
MAKE LAZARETTE WEATHER DECK HATCH WATERTIGHT.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Engineering
Issued 12 May 1994 Resolved
REPLACE ALL HOSE CLAMPS ON RAW WATER EXHAUST HOSE.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Construction/Loadline
Issued 12 May 1994 Resolved
RE-TORQUE ALL SKEG BOLTS AND REPLACE AS NECESSARY.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Construction/Loadline
Issued 12 May 1994 Resolved
REPLACE FRACTURED PLANK STARBOARD BOW AT WATERLINE.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Documentation
Issued 19 October 1993 Resolved
PRIOR TO OPERATION, PROVIDE A CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Lifesaving
Issued 23 September 1993 Resolved
PROVIDE ONE ADDITIONAL ADULT TYPE I LIFE PRESERVER. UNTIL SUCH TIME, THE TOTAL NUMBER OF PERSONS ALLOWED ABOARD IS REDUCED TO 49.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Navigation
Issued 23 September 1993 Resolved
PRIOR TO OPERATION, INSTALL A MASTHEAD LIGHT IN ACCORDANCE WITH RULE 23 ANDANNEX I OF THE NAVIGATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Construction/Loadline
Issued 23 September 1993 Resolved
RENEW THE FORWARD COMPARTMENT BILGE PICK-UP HOSE.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Documentation
Issued 27 July 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 July 1993
Resolved 27 July 1993
Unknown
Issued 23 November 1992 Resolved
PRIOR TO PLACING VESSEL IN SERVICE WITH PASSENGERS ARRANGE TO GET UNDERWAY WITH USCG MARINE INSPECTOR ONBOARD FOR THE PURPOSE OF CHECKING STRUCTURAL INTEGRITY.
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Documentation
Issued 23 September 1992 Resolved
PROVIDE DOCUMENTATION SHOWING SATISFACTORY COMPLETION OF FIRE, MAN OVERBOARD, AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 15 October 1992
Resolved 7 October 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.