Records from 1984 to 2026. Most recent: inspection, 17 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 64
17 April 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8351591
24 July 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8192603
28 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8096199
23 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7946295
30 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7686940
10 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7658189
23 May 2022
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7444037
4 May 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7443849
7 September 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7289009
19 March 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7157032
8 September 2020
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7047423
9 September 2019
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6807641
8 July 2019
Administrative Inspection · Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6742113
28 February 2019
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6627972
11 September 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6534737
8 June 2017
Internal Structural Exam · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6161691
27 April 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6124519
6 September 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5987366
5 May 2016
Construction Oversight · Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5869798
4 September 2015
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5231412
24 May 2012
DAPI Audit · COI Inspection · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4320852
7 September 2010
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3838558
14 May 2009
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3467053
29 May 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3210779
2 April 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2901574
11 January 2006
Construction Oversight · Initial Certification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2621219
9 February 2005
Construction Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2471183
7 August 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1453789
29 June 2000
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1412148
20 June 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1365829
22 November 1999
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 810307
6 July 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1087478
21 September 1998
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 799180
17 March 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 774087
10 September 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 786618
27 September 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142681
16 September 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268479
13 August 1996
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1090281
28 June 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1192218
19 October 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1411183
22 September 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877300
26 August 1995
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 878889
25 August 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 61498
23 May 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875469
25 May 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860777
12 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1169601
19 October 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 827363
23 September 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1151922
5 August 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1153454
27 July 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1156977
23 November 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1136941
9 October 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 957255
23 September 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 937167
2 October 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 934204
14 August 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1251467
2 October 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 901185
4 September 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1237053
22 September 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1329714
7 August 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1349345
13 July 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 897990
15 September 1987
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1009969
18 July 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 994341
10 March 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1301814
18 October 1984
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 981942
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel is missing 1 of the 3 fire buckets and a lanyard must be placed on all 3 fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 7 August 2024
Resolution: 3 new fire buckets have been added with attached lanyards.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 July 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Place a current chart on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 7 August 2024
Resolution: New chart placed on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 July 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The analgesic medication was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2024
Resolved 7 August 2024
Resolution: New bottle of aspirin added to first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 July 2024
Resolved
At each subsequent inspection for certification, the MI shall view the vessel afloat and conduct inspections of the hull structure and its appurtenances. 01 frame located on the stbd side mid section adjacent to the engine is cracked. Repair/replace during next drydock. OLD 46 CFR 176.25-5(a)
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 9 April 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2023
Resolved
FCC Radiosafety Cert expired. Renew.
47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 11 June 2023
Resolution: Certs renewed
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 30 May 2023
Resolved
VHF radio is not set up for DSC. Properly set up in conjunction with GPS system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 7 July 2023
Resolution: DSC installed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 September 2020
Resolved
At each subsequent inspection for certification, the MI shall view the vessel afloat and conduct inspections of the hull structure and its appurtenances. 01 frame located midsection outboard of port batteries is cracked. Repair/replace during next drydock. 46 CFR 176.25-5(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 March 2021
Resolution: Repaired using 16.5" scarfed in piece of oak, fastened using silicon bronze screws and Gflex epoxy. Screws and wood replaced in-kind.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 September 2019
Resolved
Prove proper operation of bilge system alarms audible and visual.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2019
Resolved 3 October 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 September 2019
Resolved
Properly label bilge alarms, nav lights, and all electrical switches on the console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2019
Resolved 3 October 2019
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 September 2016
Resolved
Out of service / maintenance
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 16 September 2016
Resolution: New extinguisher installed on vessel.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 September 2015
Resolved
Provide current COD.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 1 October 2015
Documentation › Certificates/Documents › FCC SSL
Issued 4 September 2015
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 1 October 2015
Fire Fighting › Ventilation Systems › Ducts
Issued 4 September 2015
Resolved
Provide means to secure vent stbd side 2nd deck for engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 1 October 2015
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 May 2012
Resolved
Provide an updated FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 19 June 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2012
Resolved
Provide an eye wash kit for the first aid kit.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 19 June 2012
Documentation › Markings/Placards › Warning Signs
Issued 24 May 2012
Resolved
Post the emergency broadcast placard.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 19 June 2012
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 September 2010
Resolved
Provide proof of drug testing program. Consortium cert and verification form.
Action required: 705 - Other - as specified
Due 14 September 2010
Resolved 10 September 2010
Resolution: Received fax of certificate of enrolment and verification form from Newport Hospital Occupational Health Services.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 September 2010
Resolved
Provide proof of crew training and drills.
Action required: 705 - Other - as specified
Due 14 September 2010
Resolved 24 September 2010
Resolution: Log of training and drills was on board and reviewed.
Engineering › Bilge Water Management System › Valve
Issued 7 September 2010
Resolved
Prove proper operation of bilge manifold valve for engine room pick up.
Action required: 705 - Other - as specified
Due 21 September 2010
Resolved 24 September 2010
Resolution: Handle was installed on valve and tested.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 May 2007
Resolved
Provide current up to date chart for all areas allowed on COI.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: On demand charts observed on board vsl.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 May 2007
Resolved
Complete proper installation of 2 courtesy lights on port side underneath fixed seating.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: Courtesy lights observed to be installed iaw manufacturers specs.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 May 2007
Resolved
Properly install proper bell mount.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: Proper bell mount witnessed to be installed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 30 May 2007
Resolved
Label breaker panel for 3 mislabeled markings as discussed.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 15 June 2007
Resolution: Breaker panel witnessed to be appropriately labeled.
Electrical
Issued 29 June 2000
Resolved
BLANK OFF OPENINGS IN ELECTRICAL DISTRIBUTION PANEL.
Condition: Unknown
Due 7 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 29 June 2000
Resolved
INSTALL A HIGH LEVEL BILGE ALARM IN THE FORWARD COMPARTMENT.
Condition: Unknown
Due 7 July 2000
Resolved 28 July 2000
Documentation
Issued 29 June 2000
Resolved
VESSEL LIMITED TO NOT MORE THAN 1,000 FEET FROM SHORE UNTIL A VALID RADIOTELEPHONY SAFETY CERTIFICATE IS ON BOARD.
Condition: Unknown
Due 7 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 29 June 2000
Resolved
REMOVE ALL RUBBER HOSES FROM THE BILGE/FIRE SYSTEM.
Condition: Unknown
Due 7 August 2000
Resolved 7 August 2000
Lifesaving
Issued 16 September 1996
Resolved
INSTALL DISCONNECT CLIP ON RING BUOY FLOATLIGHT LANYARD.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996
Resolved
PROVIDE BRIGHTLY COLORED, PROPERLY LABELED CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996
Resolved
POST EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996
Resolved
PROVIDE GUARD OVER POWER TAKE OFF PULLEY FOR FIRE PUMP.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Lifesaving
Issued 16 September 1996
Resolved
APPLY RETROREFLECTIVE TAPE TO RING BUOY.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Fire Fighting
Issued 22 September 1995
Resolved
PORTABLE FIRE EXTINGUISHER LOCATED IN FORWARD CABIN NOT PROPERLY MOUNTED. PROVIDE PROPER MOUNTING BRACKET IN ACCORDANCE WITH EXTINGUISHER APPROVAL._x001C_
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Lifesaving
Issued 22 September 1995
Resolved
APPROXIMATELY 31 LIFEPRESEVERS SINGLE STITCHED IN SHOULDER AREA. BRING LIFE PRESERVERS INTO COMPLIANCE WITH 46CFR160. APPROVAL
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Lifesaving
Issued 22 September 1995
Resolved
SEVEN (7) PERSON BOUYANT APPARATUS FADED AND DISCOLORED. BRING BUOYANT APPARATUS INTO COMPLIANCE WITH APPROVAL.
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Accommodation/Occupational Safety
Issued 22 September 1995
Resolved
PROVIDE PROPER RAILS AND GUARDS FOR FORDECK AND BRING INTO COMPLIANCE WITH 46CFR177.35
Condition: Unknown
Due 22 September 1995
Resolved 22 September 1995
Construction/Loadline
Issued 26 August 1995
Resolved
COMPLETE PERMANENT REPAIRS TO FRACTURED TRANSOM PLANKING TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR ON OR BEFORE NEXT SCHEDULED DRYDOCK 30 NOV 95.
Condition: Unknown
Due 26 August 1995
Resolved 26 August 1995
Construction/Loadline
Issued 12 May 1994
Resolved
REFASTEN PLANK ENDS BOTH PORT AND STARBOARD AT SHAFT LOG FROM GARBOARD PLANK UP TO TURN OF BILGE. _x001C_ _x001C_
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Deck/Cargo
Issued 12 May 1994
Resolved
MAKE LAZARETTE WEATHER DECK HATCH WATERTIGHT.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Engineering
Issued 12 May 1994
Resolved
REPLACE ALL HOSE CLAMPS ON RAW WATER EXHAUST HOSE.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Construction/Loadline
Issued 12 May 1994
Resolved
RE-TORQUE ALL SKEG BOLTS AND REPLACE AS NECESSARY.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Construction/Loadline
Issued 12 May 1994
Resolved
REPLACE FRACTURED PLANK STARBOARD BOW AT WATERLINE.
Condition: Unknown
Due 12 May 1994
Resolved 18 May 1994
Documentation
Issued 19 October 1993
Resolved
PRIOR TO OPERATION, PROVIDE A CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Lifesaving
Issued 23 September 1993
Resolved
PROVIDE ONE ADDITIONAL ADULT TYPE I LIFE PRESERVER. UNTIL SUCH TIME, THE TOTAL NUMBER OF PERSONS ALLOWED ABOARD IS REDUCED TO 49.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Navigation
Issued 23 September 1993
Resolved
PRIOR TO OPERATION, INSTALL A MASTHEAD LIGHT IN ACCORDANCE WITH RULE 23 ANDANNEX I OF THE NAVIGATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Construction/Loadline
Issued 23 September 1993
Resolved
RENEW THE FORWARD COMPARTMENT BILGE PICK-UP HOSE.
Condition: Unknown
Due 23 September 1993
Resolved 23 September 1993
Documentation
Issued 27 July 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 July 1993
Resolved 27 July 1993
Unknown
Issued 23 November 1992
Resolved
PRIOR TO PLACING VESSEL IN SERVICE WITH PASSENGERS ARRANGE TO GET UNDERWAY WITH USCG MARINE INSPECTOR ONBOARD FOR THE PURPOSE OF CHECKING STRUCTURAL INTEGRITY.
Condition: Unknown
Due 23 November 1992
Resolved 23 November 1992
Documentation
Issued 23 September 1992
Resolved
PROVIDE DOCUMENTATION SHOWING SATISFACTORY COMPLETION OF FIRE, MAN OVERBOARD, AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 15 October 1992
Resolved 7 October 1992