Inspection history · 31
12 November 2024
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8033846
21 February 2024
Drydock Extension · COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7868944
10 May 2023
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7671542
21 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7431873
27 April 2021
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7168922
20 November 2020
Special Consideration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7100605
6 May 2020
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6943277
19 October 2018
Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6565593
15 December 2017
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6334856
25 April 2017
Spot Check (Safety) · Administration
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6132928
27 April 2016
Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5864733
4 November 2015
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5757337
16 April 2015
Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5104024
15 April 2014
Spot Check (Safety)
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4840216
5 July 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4647413
7 May 2013
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4586391
1 May 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4299005
15 September 2011
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4149821
14 September 2011
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4149729
9 May 2011
Uninspected Other · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4007630
15 June 2010
DAPI Audit · Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3767447
21 July 2009
Uninspected Other · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3542479
3 July 2009
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3535457
30 April 2008
Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3197349
21 May 2007
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2951537
26 June 2005
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2403265
18 May 2005
Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2361365
3 January 2005
Deficiency Check · Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2267822
6 December 2001
Uninspected Towing Vessel
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1478778
27 November 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 658943
1 November 1996
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 397876
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 May 2023
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel - may be made by the use of any means and materials which result in durable markings, must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. Vessel was not marked with hailing port or vessel name at stern.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2023
Resolved 12 June 2023
Resolution: Vessel properly marked with hailing port & vessel's name.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 April 2022
Resolved
Alarm setpoints and pressure vessel relief valves required to be tested twice every 5 years, with no more than 3 years elapsing since last test. The last test of alarm setpoints and pressure vessel relief valve was completed prior to 28 March 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 3 May 2022
Resolution: Vessel representative provided copy of logs showing proper completion of required tests.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 March 2019
Resolved
Install means of closure for all engine room ventilation openings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Vent closures fabricated and employed on vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 March 2019
Resolved
Log entry for monthly fire drills in Towing Vessel Record (TVR) to include date, description of drill/scenario, and persons involved.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Log included proper entry of required fire drills.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2019
Resolved
Ensure lifeline attached to body of ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Lifeline properly attached to body of ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2019
Resolved
Locate fire axe so that it is readily accessible for use from the exterior of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Fire axe located on exterior, inboard side of starboard tow knee.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 March 2019
Resolved
Ensure monthly testing and inspection of portable fire extinguishers are conducted in accordance with National Fire Protection Association (NFPA) 10 & properly logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Monthly inspection Portable fire extinguishers properly logged.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2019
Resolved
Properly attach approved light floats to two ring buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Two ring buoys equipped with approved light floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 March 2019
Resolved
Outfit vessel with a bilge pump for emergency de-watering meeting requirements of 46 CFR 143.275.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Vessel outfitted with new portable dewatering pump and sufficient hose.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 March 2019
Resolved
Training records did not show safety orientation training topics (10 topics) had been provided to crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Training records amended to include all ten safety orientation training topics and to document that each crewmember received training.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 March 2019
Resolved
Training records did not show navigation safety training requirements (6 requirements) had been provided to non-credentialed mariners.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Training records amended to include all six navigation safety training topics and to document that each non-licensed crewmember received training.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 March 2019
Resolved
Properly document safety orientation training (def. #11) & other crew training (to include nav safety training, def. #12) with training date(s), description, names & signature of individual(s) providing training, & names of individual(s) receiving training.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Log updated to include documentation of crew training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 March 2019
Resolved
Properly equip the auxiliary generator engine with gauges at the machinery location (include the following gauges: engine lubricating oil pressure, engine RPM, and engine cooling water temperature).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Generator equipped with oil pressure, engine RPM, and engine cooling water temperature gauges.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 March 2019
Resolved
Install hand grab on port side of main deck just aft of the engine room door.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2019
Resolution: Hand grab installed on port side of main deck just aft of the engine room door.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 December 2001
Resolved
The labeling for the fuel shutoff valve was lacking the instruction for operation of the valve. LEGACY COMPONENT DESC: Label
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2002
Resolved 4 May 2004
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 December 2001
Resolved
The vessels fixed fire detection system was lacking a cetification letter from a registered professional engineer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2002
Resolved 4 May 2004
Communications › Alarms/Indicators › General Alarm
Issued 6 December 2001
Resolved
Vessel was lacking a placard for the general alarm that was legible from a short distance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 January 2002
Resolved 4 May 2004
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 6 December 2001
Resolved
Vessel was lacking a pre-sailing checklist.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2002
Resolved 4 May 2004
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 6 December 2001
Resolved
Vessel is not conducting required fire drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2002
Resolved 4 May 2004
Communications › Alarms/Indicators › General Alarm
Issued 6 December 2001
Resolved
Vessel is not conducting required weekly tests of general alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2002
Resolved 4 May 2004
Documentation
Issued 1 November 1996
Resolved
The pilot of the vessel did not have his original operators license onboard.
Condition: Unknown
Due 2 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 1 November 1996
Resolved
The official number was not permanently marked on an interior structural part of the hull.
Condition: Unknown
Due 1 December 1996
Resolved 18 May 2002