INDUSTRIAL DREAM is a 2007 freight ship. The Coast Guard has recorded 22 inspections since 2017, most recently in April 2026, along with 8 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: inspection, 6 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it2918 - Convention (Subpart B), Net Ton 7968 - Dead Weight, Metric Ton 12372 - Displacement, Metric Ton 7223 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 September 2025Resolved
Fire protection systems shall be kept in good order ensure their required performance if a fire occurs; which includes structural fire protection, fire resistent divisions, openings, and penetrations. PSCO observed the escape trunk door in the lower E/R with unauthorized gasket material which was not in accordance with manufacturer specs or FTP code test procedures.
74 SOLAS (20) II-2/2.1.1.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 November 2025
Resolution: VESSEL SENT IN SUPPORTING DOCUMENTS TO CLEAR DEF.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 September 2025Resolved
One of these ladders shall be located within a protected enclosure that satisfies regulation 9.2.3.3, category (4), form the lower part of the space it serves to a safe position outside the space. Self-closing fire doors of the same fire inegrity standards shall be fitted in the enclosure. PSCO observed lower engine room emergency escape trunk fire door not meeting structural fire protection standards.
74 SOLAS (09) II-2/13.4.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2025
Resolution: Ship installed new structural fire protection inside the escape trunk, and freed the fire door for operation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 October 2022Resolved
Staryways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class doors and not be in open position. Galley dooors were fixed in the open position.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 October 2022
Resolved 13 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 October 2022Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. 03 Life0rafts were improperly installed preventing them from floating free.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 October 2022
Resolved 13 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 October 2022Resolved
Lifebouys complying with the code shall be readily available on both sides of the ship as far as practicable on all open decks. Vessel had missing lifebuoy and floating light on starboard side.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 13 October 2022
Resolved 13 October 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 October 2022Resolved
The company and ship shall comply with the requirements of the ISM Code. Company should establish procedures, plans, and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. The various tasks should be defined and assigned to qualified personnel. Vessel crew did not follow SMS items "5.2.2 " & "5.2.11" of "2M-0701" instructions manual for deficiencies above.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 14 April 2023
Resolution: Received class email stating the company has completed an ISM Audit with additional training and instruction for LSA and FSS
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 June 2019Resolved
07126 - To prevent the ignition of flammable liquids, ignition sources shall be restricted. Pooled oil was observed in the oil purifier room, posing as an ignition source thus, a risk to ship and crew. (SOLAS 74 (2004) Ch. II-2 Part B 4.1.4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 June 2019
Resolution: Crew cleaned oil and verified no active leaks.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 June 2019Resolved
07199 - No flammable liquids may be stowed in any accommodation, control, or service space (other than a paint locker). Fuel oil samples were found not stored in flammable proof locker. (46 CFR 147.45(b))
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2019
Resolved 25 June 2019
Resolution: Received proper documentation attesting to the correction of the deficiency.