MAURY USCG vessel records
← All vessels

FLYIN' HIGH

FLYIN' HIGH is a 2009 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in June 2026, along with 24 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 1 June 2026.

Built
2009
Last inspected
1 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 June 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ9844
1012716
Flag
UNITED STATES
Maury page id
psix-1012716

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

1 June 2026 Administrative Inspection · Vessel Attendance · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8373691
2 February 2026 Administrative Inspection · Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304903
6 May 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8129397
30 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8127044
28 August 2024 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7991358
26 April 2024 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7901746
17 April 2024 Administrative Inspection · Deficiency Check · Special Consideration · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7889996
23 February 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7869091
5 June 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7703891
23 March 2022 Drydock Exam · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7413147
7 July 2020 DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6992530
10 March 2020 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6921700
2 April 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6655394
22 May 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6415883
26 April 2018 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6395640
9 May 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6139126
7 June 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5899791
26 April 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5860524

Deficiency record · 24

05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 April 2025 Resolved
FCC Station License not onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 1 June 2026
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 April 2025 Resolved
Vessel must have sound signal device onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 17 February 2026
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2025 Resolved
Vessel's ring buoy is no longer serviceable; out plastic shell is cracked exposing inner foam material.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2025 Resolved
Starboard fuel oil shutoff valve is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 6 May 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 April 2025 Resolved
Vessel's digital engine monitoring display is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2025
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 April 2025 Resolved
Vessel owner/operator must be enrolled as a Marine Employer with consortium.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 1 June 2026
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 April 2024 Resolved
Starboard remote fuel oil shutoff valve does not fully close. The operation of the valve is impeded by hose & wiring bundle.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 18 April 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 April 2024 Resolved
Vessel did not have means to close ventilation openings in engine compartment to prevent exhaust of fire extinguishing agent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 26 April 2024
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2022 Resolved
Vessels port fuel tank has a leak. Repair or replace tank and make available for CG Marine Inspector repair check prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2022
Resolution: Leak was coming from fill fitting; resealed and tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2022 Resolved
Provide proof of required flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2022
Resolution: New flares provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2022 Resolved
Replace or renew life ring and lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2022
Resolution: New life ring and lines provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 18 May 2022 Resolved
Provide proof of consortium enrollment for all crew members.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2022
Resolution: Proof of enrollment provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 May 2022 Resolved
Update all required nautical publications(Tide table, BNM, LL, Coast pilot, etc)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2022
Resolution: All publications provided.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 18 May 2022 Resolved
Properly mark EPIRB hydro release.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2022
Resolution: EPIRB properly marked.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020 Resolved
Provide proof of FCC Station License.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Owner provide proof of new certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020 Resolved
Provide proof of FCC Station Radio Telephony certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 26 May 2022
Resolution: FCC cert provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2020 Resolved
Provide proof of ALCO test strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Owner provide new ALCO strips.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 July 2020 Resolved
EPIRB hydrostatic release expired, renew in kind.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Owner provided new release.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2020 Resolved
Both bilge pumps and high water alarms were inoperative. Repair and test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Owner demonstrated bilge pump and alarm operation.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 July 2020 Resolved
Navigation lights were inoperative, repair and test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Tested NAV Lights, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2020 Resolved
Seal bulkhead penetrations in engine room. Caulk and test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Bulkhead penetrations sealed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020 Resolved
Update tide table, coast pilot and BNTM 2020 editions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Owner provide proof of current nautical publications required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 July 2020 Resolved
Add additional fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Owner added additional fire bucket required.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 April 2018 Resolved
Complete credit annual exam. Vessel is currently undergoing engine maintanance.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2018
Resolved 22 May 2018
Resolution: conducted annual exam; all SAT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.