Records from 2016 to 2018. Most recent: inspection, 9 December 2018.
Inspection history · 8
9 December 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6612885
14 June 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6449044
27 July 2017
Administrative Inspection · In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6226724
24 January 2017
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6077725
31 July 2016
COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963279
4 July 2016
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5938619
18 April 2016
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5907664
9 January 2016
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5794274
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 24 January 2017
Resolved
air cylinder hoses were found with leaks
Condition: Placed in Improper Service
Due 23 February 2017
Resolved 9 April 2017
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 24 January 2017
Resolved
run through cable penetrations were found missin part of the rise
Condition: Improper/Lack of Maintenance
Due 8 February 2017
Resolved 24 February 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 January 2017
Resolved
doors were missing handles and did not fully close
Condition: Improper/Lack of Maintenance
Due 8 February 2017
Resolved 24 February 2017
Lifesaving › Lifeboat › Propulsion Starting System
Issued 18 April 2016
Resolved
Lifeboat #4 engine would not start on either battery due to broken connection
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2016
Resolved 18 August 2016
Resolution: corrected on the spot
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 18 April 2016
Resolved
Lifeboat #s 2 & 3 have faulty main, remote steering, wheen wheel is put over, rudder may be unresponsive or sluggish and intermittent
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 25 April 2016
Resolution: steering rams were found to be leaking fluid, causing them to not operate correctly. Steering rams on all lifeboats (1-6) were replaced and photos /e-mail attesting to this were provided.
Construction/Loadline › Structures › Door
Issued 18 April 2016
Resolved
Self-closing A-class door in the warehouse ws tied back with fiber line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: corrected on the spot, fiber line holding door back was removed
Operations/Management › Drills/Instruction › Abandon Ship
Issued 18 April 2016
Resolved
Muster was not achieved during abandon ship drill. Inspectors had taken crew members aside during drill and the muster takers could not account for them in a timely fashion.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 26 April 2016
Resolution: Multiple drills held with crew by Master's account and displaced crew members accounted for. Mustering procedures were changed and drilled to ensure accountability of crew members in a timely fashion and id missing persons.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 18 April 2016
Resolved
Lifeboat # 1 has parted hand grab line on exterior of boat due to boat gripe chaffing thru the line and all lifeboats showed chaffing on grab lines from boat gripes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 26 April 2016
Resolution: grab line on #1 lifeboat was replaced to original and lines on the other 5 lifeboats were inspected and determined adequate. Crew will monitor chaffing of grab lines to prevent further breakage