SOCRATES is a 2007 tank ship. The Coast Guard has recorded 11 inspections since 2017, most recently in September 2025, along with 6 deficiencies and 2 operational controls.
Records from 2017 to 2025. Most recent: inspection, 17 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it41676 - Convention (Subpart B), Gross Ton 21792 - Convention (Subpart B), Net Ton 35785 - Simplified, Gross Ton 74327 - Dead Weight, Metric Ton 88225 - Displacement, Metric Ton 28628 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
11 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
17 September 2025PSC B · Administrative Inspection · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8235946
15 August 2024PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981826
18 August 2023COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7765680
16 August 2022COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7525427
18 August 2021PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7283779
12 August 2020COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7030928
11 August 2020Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7030448
6 March 2019ISPS II Exam · Ballast Water Examination · COC-TVE Renew · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6632944
20 April 2018ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6392498
30 January 2017ISPS II Exam · Administrative Inspection · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6079933
30 January 2017Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6080402
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 August 2023Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. PSCO found 01 cracked explosion proof lens in the Cargo Pump Room, 03 broken/disconnected grounding straps on explosion proof lighting fixtures in the pump room and 01 explosion proof light fixture with improperly installed cabling, without any packings going into the fixture. Rubber tape has been used instead of packing on cable.
74 SOLAS (04) 45.5
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 18 August 2023
Resolved 28 August 2023
Resolution: Received class report stating correction deficiencies to the satisfaction of class and flag.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 August 2023Resolved
No person may use any equipment of this section for transfer operations unless the vessel tests and inspects the equipment of this section. Each item of remote operating or indicating equipment such as a tank level alarm. PSCO was informed of unreported condition of class for #3 COT Port and Starboard tank radar, risk assessment had been completed. Class and flag had not been informed, PSCO prompted report. Tank radar inoperable for #3 COT Port and Starboard. Flag dispensation issued and valid until 01Sept2023.
33CFR156.170(c)(5)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 18 August 2023
Resolved 28 August 2023
Resolution: The deficiency was rectified to the satisfaction of their administration, flag dispensation for faulty tank radar has been recinded as of this date.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 March 2019Resolved
A FIXED HIGH EXPANSION FOAM FIRE-FIGHTING SYSTEM COMPLYING WITH THE PROVISIONS OF THE FIRE SAFETY SYSTEMS CODE; THE QUANTITY OF FOAM CONCENTRATE AVAILABLE SHALL BE SUFFICIENT TO PRODUCE A VOLUME OF FOAM EQUAL TO AT LEAST FIVE TIMES THE VOLUME OF THE LARGEST SPACE ENCLOSED BY STEEL BULKHEADS, AT THE NOMINAL EXPANSION RATIO OR ENOUGH FOR 30 MIN OF FULL OPERATION FOR THE LARGEST PROTECTED SPACE, OR WHICHEVER IS GREATER. THE MINIMUM REQUIRED QUANTITY OF FOAM CONCENTRATE TO PROTECT THE SHIP’S LARGEST PROTECTED SPACE (ENGINE ROOM) IS 916 LITERS. THE SHIP HAS APPROXIMATELY 736 LITERS OF THE MINIMUM REQUIRED CAPACITY. ON 26FEB19, A MONTHLY INSPECTION REQUIRED BY THE SHIP’S SMS MANUAL (FORM SOM-1) WAS CONDUCTED BY THE CREW AND THE ASSOCIATED RECORD SHEET INDICATED THAT THE FOAM SYSTEM WAS “NIL.” THIS INSPECTION INCLUDED VERIFYING THE AMOUNT OF FOAM IN THE SYSTEM. THE FLAG DISPENSATION LETTER (ISSUED ON 06MAR19) WAS REVOKED BY FLAG ADMINISTRATION AFTER THE FLAG STATE INSPECTOR ONBOARD DISCOVERED THAT THE FOAM LEVEL ONBOARD WAS BELOW THE MINIMUM LEVEL REQUIRED.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 March 2019
Resolved 12 March 2019
Resolution: Vessel replaced entire high expansion foam onboard. PSCOs verified levels and confirmed that class report detailed class surveyor witnessing delivery of new foam and maintaining of sightglass.
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. FOR THE PURPOSE OF THIS REGULATION, THE REQUIREMENTS OF THE CODE SHALL BE TREATED AS MANDATORY. IN MEETING THESE REQUIREMENTS, THE COMPANY SHOULD ENSURE THAT THE RECORDS OF THESE ACTIVITIES ARE MAINTAINED. RECORDS OF MONTHLY FIRE-FIGHTING EQUIPMENT INSPECTIONS AS REQUIRED BY SHIP’S SMS ARE SPORADICALLY MISSING INSPECTION ENTRIES SINCE MARCH 2018, INCLUDING DATES AND “REMARKS/DEFICIENCIES”. DESPITE MISSING ENTRIES IN THE SHIP’S SMS RECORDS, RECORDS HAVE STILL BEEN SIGNED BY SHIPBOARD MANANGEMENT INDICATING THEY WERE REVIEWED. ADDITIONALLY, DUE TO THE SYSTEM NOT BEING MAINTAINED AS PER SMS SCHEDULE, THE OPERATIONAL CONDITION IMPOSED BY FLAG DISPENSATION LETTER FOR THE FIXED FIRE-FIGHTING (WATER-MIST SYSTEM) IS UNKNOWN.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2019
Resolved 18 March 2019
Resolution: TRAINING CONDUCTED AND CERTIFIED BY CLASS
Electrical › Electric Generation Source (service) › Generator
Issued 30 January 2017Resolved
74SOLAS(2014 CONS. ED.)II-1/43.3.1.3 The emergency source of electrical power may be either a generator or an accumulator battery, which shall comply w/ the following: Provided w/ a transitional source...supplying the required load as quickly as is safe and practicable subject to a max of 45 s. Vessel's generator cannot take a load. 60ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2017
Resolution: 1FEB17 Recieved class report from ABS LA3277344 attesting to the replacement of the malfunctioning emergency generator breaker. Operational test was conducted and found satisfactory.
Engineering › Steering Gear System › Feedback Unit
Issued 30 January 2017Resolved
74SOLAS(2014 CONS. ED.)II-1/30.3 Short circuit protection and an overload alarm shall be provided for such circuits and motors. Protection against excess current, including starting current, if provided, shall be for not less than twice the full load current of the motor or circuit...appropriate starting currents. Vessel's electric over current relay is inoperable. 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 February 2017
Resolution: Received class report attestint to the replacement of the overcurrent relay and successful operational test.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.