← All vessels
SOCRATES
SOCRATES is a 2007 tank ship. The Coast Guard has recorded 12 inspections since 2014, most recently in September 2025, along with 6 deficiencies and 2 operational controls.
Records from 2014 to 2025. Most recent: inspection, 17 September 2025.
- Built
- 2007
- Last inspected
- 17 September 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9390692 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A80E2
1013484
Flag
LIBERIA
—
Maury page id
psix-1013484
Inspections, by type
…with no type recorded2
Years with a record
10 calendar years (2014–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it41676 - Convention (Subpart B), Gross Ton
21792 - Convention (Subpart B), Net Ton
35785 - Simplified, Gross Ton
74327 - Dead Weight, Metric Ton
88225 - Displacement, Metric Ton
28628 - Simplified, Net Ton
21792 - Convention (Subpart B), Net Ton
35785 - Simplified, Gross Ton
74327 - Dead Weight, Metric Ton
88225 - Displacement, Metric Ton
28628 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
17 September 2025
PSC B · Administrative Inspection · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8235946
15 August 2024
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981826
18 August 2023
COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7765680
16 August 2022
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7525427
18 August 2021
PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7283779
12 August 2020
COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7030928
11 August 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7030448
6 March 2019
ISPS II Exam · Ballast Water Examination · COC-TVE Renew · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6632944
20 April 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6392498
30 January 2017
ISPS II Exam · Administrative Inspection · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6079933
30 January 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6080402
28 October 2014
ISPS II Exam · COC-TVE Annual · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5012934
Deficiency record · 6
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 August 2023
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization. PSCO found 01 cracked explosion proof lens in the Cargo Pump Room, 03 broken/disconnected grounding straps on explosion proof lighting fixtures in the pump room and 01 explosion proof light fixture with improperly installed cabling, without any packings going into the fixture. Rubber tape has been used instead of packing on cable.
74 SOLAS (04) 45.5
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 August 2023
Resolved
No person may use any equipment of this section for transfer operations unless the vessel tests and inspects the equipment of this section. Each item of remote operating or indicating equipment such as a tank level alarm. PSCO was informed of unreported condition of class for #3 COT Port and Starboard tank radar, risk assessment had been completed. Class and flag had not been informed, PSCO prompted report. Tank radar inoperable for #3 COT Port and Starboard. Flag dispensation issued and valid until 01Sept2023.
33CFR156.170(c)(5)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 March 2019
Resolved
A FIXED HIGH EXPANSION FOAM FIRE-FIGHTING SYSTEM COMPLYING WITH THE PROVISIONS OF THE FIRE SAFETY SYSTEMS CODE; THE QUANTITY OF FOAM CONCENTRATE AVAILABLE SHALL BE SUFFICIENT TO PRODUCE A VOLUME OF FOAM EQUAL TO AT LEAST FIVE TIMES THE VOLUME OF THE LARGEST SPACE ENCLOSED BY STEEL BULKHEADS, AT THE NOMINAL EXPANSION RATIO OR ENOUGH FOR 30 MIN OF FULL OPERATION FOR THE LARGEST PROTECTED SPACE, OR WHICHEVER IS GREATER. THE MINIMUM REQUIRED QUANTITY OF FOAM CONCENTRATE TO PROTECT THE SHIP’S LARGEST PROTECTED SPACE (ENGINE ROOM) IS 916 LITERS. THE SHIP HAS APPROXIMATELY 736 LITERS OF THE MINIMUM REQUIRED CAPACITY. ON 26FEB19, A MONTHLY INSPECTION REQUIRED BY THE SHIP’S SMS MANUAL (FORM SOM-1) WAS CONDUCTED BY THE CREW AND THE ASSOCIATED RECORD SHEET INDICATED THAT THE FOAM SYSTEM WAS “NIL.” THIS INSPECTION INCLUDED VERIFYING THE AMOUNT OF FOAM IN THE SYSTEM. THE FLAG DISPENSATION LETTER (ISSUED ON 06MAR19) WAS REVOKED BY FLAG ADMINISTRATION AFTER THE FLAG STATE INSPECTOR ONBOARD DISCOVERED THAT THE FOAM LEVEL ONBOARD WAS BELOW THE MINIMUM LEVEL REQUIRED.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 6 March 2019
Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. FOR THE PURPOSE OF THIS REGULATION, THE REQUIREMENTS OF THE CODE SHALL BE TREATED AS MANDATORY. IN MEETING THESE REQUIREMENTS, THE COMPANY SHOULD ENSURE THAT THE RECORDS OF THESE ACTIVITIES ARE MAINTAINED. RECORDS OF MONTHLY FIRE-FIGHTING EQUIPMENT INSPECTIONS AS REQUIRED BY SHIP’S SMS ARE SPORADICALLY MISSING INSPECTION ENTRIES SINCE MARCH 2018, INCLUDING DATES AND “REMARKS/DEFICIENCIES”. DESPITE MISSING ENTRIES IN THE SHIP’S SMS RECORDS, RECORDS HAVE STILL BEEN SIGNED BY SHIPBOARD MANANGEMENT INDICATING THEY WERE REVIEWED. ADDITIONALLY, DUE TO THE SYSTEM NOT BEING MAINTAINED AS PER SMS SCHEDULE, THE OPERATIONAL CONDITION IMPOSED BY FLAG DISPENSATION LETTER FOR THE FIXED FIRE-FIGHTING (WATER-MIST SYSTEM) IS UNKNOWN.
Electrical › Electric Generation Source (service) › Generator
Issued 30 January 2017
Resolved
74SOLAS(2014 CONS. ED.)II-1/43.3.1.3 The emergency source of electrical power may be either a generator or an accumulator battery, which shall comply w/ the following: Provided w/ a transitional source...supplying the required load as quickly as is safe and practicable subject to a max of 45 s. Vessel's generator cannot take a load. 60ac
Engineering › Steering Gear System › Feedback Unit
Issued 30 January 2017
Resolved
74SOLAS(2014 CONS. ED.)II-1/30.3 Short circuit protection and an overload alarm shall be provided for such circuits and motors. Protection against excess current, including starting current, if provided, shall be for not less than twice the full load current of the motor or circuit...appropriate starting currents. Vessel's electric over current relay is inoperable. 40ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.