Records from 1987 to 2019. Most recent: inspection, 22 July 2019.
Documentation record
Registered dimensions (L × B × D)37.5 ft × 12.7 ft × 6.0 ft
Registered tonnagegross 19 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHERMODYNE INC & HOQUIAM · MARYSVILLE, WA, UNITED STATES · built 1969
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKETCHIKAN, AK
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Net Ton
19 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
22 July 2019
Type not recorded
No type recorded · Station Ketchikan · USCG Arctic District (CGD-A) · Activity 6763122
2 May 1996
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1082175
12 May 1995
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1468350
5 May 1995
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1374283
21 April 1994
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1377164
26 June 1993
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1359596
19 April 1993
Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1436745
8 December 1992
Drydock Extension
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 826215
23 March 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1258751
18 June 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1210651
29 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1229564
10 May 1991
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1232268
26 September 1990
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1238926
7 May 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 915672
21 June 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1202391
4 May 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1042919
26 April 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 895307
6 April 1989
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1210134
23 February 1989
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1353095
8 July 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1208056
24 March 1987
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1021218
Fire Fighting
Issued 6 April 1989
Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Electrical
Issued 6 April 1989
Resolved
RENEW 12 VOLT BATTERY CABLE TERMINALS UTILIZING BOLT ON TYPE CONNECTIONS.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Engineering
Issued 6 April 1989
Resolved
RENEW FUEL LINE HOSE (FLEXIBLE) BETWEEN TANK AND FUEL FILTER UTILIZING U.S.C.G. APPROVED FUEL HOSE.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Lifesaving
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE A WEAK-LINK FOR THE BUOYANT APPARATUS AND RE-PACK THE PAINTER.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Lifesaving
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, ATTACH THE BUOYANT APPARATUS WATER LIGHT TO THE BUOYANT APPARATUS.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Navigation
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE A WORKING HAND TILLER FOR EMERGENCY STEERING.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Lifesaving
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE SIX RED AND SIX ORANGE DISTRESS FLARES.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Fire Fighting
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, SERVICE THE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Electrical
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, SECURE ALL LOOSE WIRING IN THE ENGINE SPACE.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Navigation
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPAINT OR RESTENCIL ALL LIFE SAVINGAPPLIANCES AND HULL WITH VESSEL'S NEW NAME.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Fire Fighting
Issued 24 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE AN ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR PROTECTION OF THE ENGINE SPACE. THIS IS AN INCREASE IN THE NUMBER OF REQUIRED B-II FIRE EXTINGUISHERS FOR A TOTAL OF THREE B-IIAND ONE B-I EXTINGUISHERS.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987