BUXCLIFF

BUXCLIFF is a freight ship. The Coast Guard has recorded 40 inspections since 2016, most recently in July 2024, along with 27 deficiencies and 14 operational controls.

Records from 2016 to 2024. Most recent: inspection, 26 July 2024.

Built
Not recorded
Last inspected
26 July 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 July 2024
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9221815
1014105
Flag
PORTUGAL
Maury page id
psix-1014105

Documentation record

Tonnage as PSIX records it72760 - Convention (Subpart B), Gross Ton
41077 - Convention (Subpart B), Net Ton
79504 - Dead Weight, Ton
106041 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 40

26 July 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8011805
25 July 2024 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7967307
24 July 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7963876
25 April 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7901173
15 April 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7893523
12 October 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7804554
2 March 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7643896
17 November 2022 PSC B · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7593284
28 July 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7516662
24 July 2022 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7514609
23 April 2022 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7436396
3 April 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7413756
3 November 2021 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7344521
19 October 2021 PSC A · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7332918
19 June 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7229428
26 May 2021 PSC B · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7207347
15 April 2021 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7175891
6 February 2021 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7133597
2 August 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7022439
20 July 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7011309
20 July 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7011490
5 June 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6968771
3 June 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6966924
2 June 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6965943
28 May 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6962515
29 April 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6945490
24 April 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6943525
15 April 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6939329
14 April 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6938778
27 February 2020 PSC C
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6916668
5 February 2020 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6903159
21 December 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6877590
18 December 2019 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6876220
12 October 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6833235
10 March 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6102369
29 February 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5823806
26 February 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5822814
19 February 2016 PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5818370
19 February 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5823842
18 February 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5817256

Deficiency record · 27

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 July 2024 Resolved
Machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. While vessel was transiting outbound Chief Engineer discovered an indicator valve on the main engine cylinder head #10 was blowing down strong exhaust gases resulting in an abnormal noise. Indicator valve had a failed block screw. 74SOLAS(04) II-1 / 26.1
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 25 July 2024
Resolution: Block screw was replaced and tests were carried ot to verify repairs.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 15 April 2024 Resolved
EVERY SHIP 100 GT AND ABOVE SHALL CARRY A GARBAGE MANAGEMENT PLAN WHICH THE CREW SHALL FOLLOW. PSCO OBSERVED STORAGE OF GARBAGE, TO INCLUDE MULTIPLE EMPTY OIL CANS AND WORN HOSES, IN PORT TUNNEL. VESSELS GARBAGE MANAGEMENT PLAN DOES NOT ALLOW FOR STORAGE OF GARBAGE IN TUNNELS. MARPOL 73/78 ANNEX V/Reg. 10.2 15c
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 25 April 2024
Resolution: Vessel provided Class Survey.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 15 April 2024 Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS SHALL BE SO INSTALLED AND PROTECTED TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS. FUEL OIL STEAM PIPES IN BOTH PORT + STBD TUNNELS MISSING INSULATION, EXPOSING HOT PIPES. 74 SOLAS (04) II-1/26.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 April 2024
Resolution: Vessel provided Class Survey.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 April 2024 Resolved
SATISFACTORY MEANS SHALL BE PROVIDED FOR THE PROTECTION OF THE CREW IN GETTING TO AND FROM THEIR QUARTERS, MACHINERY SPACE AND ALL OTHER PARTS USED IN NECESSARY WORK OF THE SHIP. PSCOS OBSERVED STBD LADDER FROM FORECASTLE TO MAIN DECK AND FWD PORT TUNNEL TO MAIN DECK BOTH SEVERLY WASTED. ILLC 1/25.4 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 April 2024
Resolution: Vessel provided Class Survey.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 November 2022 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed, and maintained in compliance with the structural, mechanical and electrical requirements of a classification society. Bureau Veritas to provide repair proposal for wastage and pitting identified on heavy fuel oil tanks #3 starboard side and #4 port side. Additional fractures identified along transverse frame 82. SOLAS (2004) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2022
Resolved 17 November 2022
Resolution: Received class report rectifing the deficiency.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 November 2022 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Identified ventilation cannot be close from outside spaces of CO2 room, Steering, Port and Starboard Passageway. SOLAS (2001) II-2/16.9
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2022
Resolved 17 November 2022
Resolution: Obtained class report rectifing the deficiencies.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 November 2022 Resolved
The machinery, boiler and other pressure vessels, associated pipping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Identified excess oil in bilge of aft cargo hold #4. SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 March 2023
Resolution: Obtained class report rectifying repair of cargo hold.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 3 April 2022 Resolved
The ventilation systems of cargo ships shall be in compliance with the provisions of Regulation 16, except paragraph 8. Ship's crew identified damage in ventilation in cargo holds 3, 4, and 5. 74 SOLAS (2001 cons) II-2/Reg 48
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 July 2022
Resolution: Received Class reports attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 October 2021 Resolved
Doors fitted in boundry bulkheads of machinery spaces of category "A" shall be reasonably gas tight and self-closing. PSCO observed damage to the fire door frame leading to the steering gear room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 November 2021
Resolved 3 November 2021
Resolution: Class reports submitted
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2021 Resolved
The contidions of the ship and its equipment shall be maintained to conorm wuth the provisions of present regulations. PSCO observed a water leak on the #12 cylinder.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 November 2021
Resolved 3 November 2021
Resolution: Class reports submitted
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2021 Resolved
The contidions of the ship and its equipment shall be maintained to conorm wuth the provisions of present regulations. PSCO observed a modification to the waste oil line.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 November 2021
Resolved 3 November 2021
Resolution: Class reports submitted
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2021 Resolved
The contidions of the ship and its equipment shall be maintained to conorm wuth the provisions of present regulations.PSCO observed emergency escape route blocked.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2021
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 October 2021 Resolved
Every oil fuel pope, if damaged, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. PSCO observed the emergency stops on all 04 fuel tanks were blocked.
Action required: 10 - Deficiency Rectified
Resolved 19 October 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 May 2021 Resolved
In a ship in which oil fuel is used, the arrangements for storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Five gallons of fuel oil and multiple oil soaked rags observed in containment of purifier space due to a 10cm crack in very low sulfur service tank leaking approximately 60 liters/day. Additionally, main engine has significant accumulation of fuel oil around all cylinder heads and over the entire body of the engine presenting insufficient cleanliness of engine room and multiple fire hazards throughout the engine room.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 10 June 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 May 2021 Resolved
"A" class divisions are those divisions formed by bulkheads and decks which are constructed of steel or other equivalent material, be suitably stiffened, and so constructed to prevent passage of smoke and flame to the end of the one-hour standard fire test. Crew intentionally cut approximately 12”x8” hole in A-0 bulkhead between corridor and Engine Room, compromising vessel's structural fire protection.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 10 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 May 2021 Resolved
Cargo spaces for dangerous goods shall be fitted with either a fixed fire detection and fire alarm system complying with the requirements of Regulation 13 or a sample extraction smoke detection system complying with the requirements Regulation 13-1. Cargo hold smoke detection system found in continuous alarm status with multiple errors since January 2021.
Action required: 30 - Ship detained
Resolved 10 June 2021
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 May 2021 Resolved
Means of effectively cooling the designated under-deck cargo space by copious quantities of water by spraying nozzles or flooding the cargo space with water shall be provided. Fire main connection for hose is significantly wasted at cargo hold no. 1 and a hose cannot be threaded, demonstrating an inability to effectively fight a fire of certain dangerous cargo in cargo hold no. 1.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 June 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 May 2021 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency including emergency lighting for muster and embarkation station, over the sides, and all service and accommodation alleyways. Over 20 emergency lights failed through multiple areas of deck, embarkation areas and accommodation alleyways, and would not be available in the event of an emergency.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 June 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 May 2021 Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Paint Locker sprinklers have significant rust accumulated on sprinkler head posing significant risk of extinguishing capability in the event of a fire in paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 May 2021 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Observed crew unable to close ventilation to cargo hold no. 3 presenting significant risk in the event of a fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 26 May 2021 Resolved
The International Loadline Certificate shall not be issued to the ship unless the officer or surveyor acting under the provisions of article 13 of the present Convention has certified that the marks are correctly and permanently indicated on the ship's side. Loadline marked on port side of vessel does not match valid Loadline Certificate onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 26 May 2021 Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations. Based on the overall materiel condition of the vessel as substantiated by the objective evidence cited above, an additional external verification is required.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 6 February 2021 Resolved
PORT SIDE PILOT DOOR INOPERABLE. RECTIFIED ON THE SPOT.
Action required: 10 - Deficiency Rectified
Due 6 February 2021
Resolved 15 April 2021
Resolution: Corrected on spot.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 6 February 2021 Resolved
CO2 ROOM VENTILATION WAS INOPERABLE. 74 SOLAS (14) II-2/5.1.13
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2021
Resolved 15 April 2021
Resolution: Received class report.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 6 February 2021 Resolved
AFT STRBD HIGH LEVEL BILGE ALARM INOPERABLE.74 SOLAS (2001) II-1/38
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 15 April 2021
Resolution: Received class report.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 18 December 2019 Resolved
Ship lost it's UMS capability due to the loss of machinery remote control caused by a failure of the electronic governer, and now requires an additional EOW and Engine Rating which none are present on board ship, posing a safety risk.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: verified coc for additional engine rating
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 19 February 2016 Resolved
See Narative
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2016
Resolved 19 February 2016
Resolution: Recieved causal analysis along with class report. Class report is attached in documents.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.