MAURY USCG vessel records
← All vessels

STAR EAGLE

STAR EAGLE is a 2007 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in June 2025, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 16 June 2025.

Built
2007
Last inspected
16 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 June 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9321938
1014253
Flag
CYPRUS
Maury page id
psix-1014253

Documentation record

Tonnage as PSIX records it30068 - Convention (Subpart B), Gross Ton
13648 - Convention (Subpart B), Net Ton
49790 - Dead Weight, Metric Ton
60033 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

16 June 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8158625
26 March 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7881865
5 March 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7645509
14 August 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7527925
16 May 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7198089
2 February 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7133022
21 January 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7128402
13 January 2020 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6887517
1 October 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6825471
2 March 2019 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6635290
28 January 2019 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6613904
13 January 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797021

Deficiency record · 3

14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 14 August 2022 Resolved
Subject to this provision, oil discharge monitoring and control system approved by the administartion. PSCO observed ODME cargo sampling intake line found holed during deck exam. Conduct repairs prior to operational use of ODME. MARPOL 73/78 An I-31 A/C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2022
Resolved 4 March 2023
Resolution: Received class report attesting to repairs on the cargo sampling intake line.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 January 2020 Resolved
07106 Fire Safety The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs; fire detector and fire alarm systems. PSCO observed 04 Engine room fire & machinery alarm panels inoperable, including 01 incapable of producing light or sound. 74 SOLAS (a) 2014 cons. II-2/14.2.1.1.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2020
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Broken/burned out fuses and bulbs replaced and all panels tested satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 January 2020 Resolved
11129 Life Saving Appliances Each survival craft shall be stowed: in a state of continuous readiness so that two crewmembers can carry out preparations for the embarkation and launching in less than 5 mins. PSCO observed that the forward lashing gripe on the port side lifeboat did not release during launching. Installed gripe with pin & shackle arrangement prevented proper release and was improper according to the vessel's lifeboat maintenance plan. A requirement was issued to provide a class report stating that it has been rectified prior to departure of the vessel. SOLAS 74(a) 2014 cons. III/13.1.3 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2020
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Proper gripes using Ring Links loaded onboard and installed on the lifeboat.

Ownership record