This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it17822 - Convention (Subpart B), Gross Ton 6662 - Convention (Subpart B), Net Ton 25419 - Dead Weight, Ton 32445 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
30 April 2022COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7432068
7 January 2020Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6885999
6 January 2020Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6883189
30 November 2017ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6315319
3 June 2016COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2020Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. The no. 4 lighting dist. board has 30A breaker listed on placard but has a 40A breaker installed. The waste oil incinerator has 40A breaker listed on placard but has a 50A breaker installed. The no. 2 H.F.O. purifier has a 20A breaker listed on placard but has a 40A breaker installed. The air compressor "Atlas Copco" has a 15A breaker listed on placard but has a 100I breaker installed. This breaker is also not flush with the front of the breaker panel requiring crew to insert finger into breaker panel to secure the breaker.
74 SOLAS(09)/II-1 40.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2020
Resolution: Recieved class report
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National