Records from 2009 to 2023. Most recent: inspection, 4 April 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
4 April 2023
Uninspected Passenger Vessel
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7778888
8 May 2021
Uninspected Passenger Vessel
Physical examination · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 7390052
14 April 2019
Uninspected Passenger Vessel
Physical examination · USCG Arctic District · USCG Arctic District (CGD-A) · Activity 6908158
13 April 2019
Uninspected Passenger Vessel
Physical examination · USCG Arctic District · USCG Arctic District (CGD-A) · Activity 6907428
10 April 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6660172
20 September 2018
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6545322
6 August 2018
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6503000
1 June 2017
Administrative Inspection · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6161965
25 July 2016
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5952533
14 May 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5878753
11 May 2016
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5874794
28 August 2014
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4968250
11 August 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4951993
25 January 2012
Deficiency Check · Internal Structural Exam · Administrative Inspection · Hull Examination · Simplified Stability Test · Initial Certification
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4231880
1 May 2009
Uninspected Passenger Vessel
Physical examination · USCG Arctic District (dr) · USCG Arctic District (CGD-A) · Activity 3500641
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 September 2018
Resolved
Vessel has only 4 of required 6 flares that are not expired. Provide 2 unexpired flares - 46 CFR 180.68
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 13 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 September 2018
Resolved
Aspirin, burn gel, and eyewash in first aid kit expired. Replace expired meds in first aid kit - 46 CFR 184.710
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 13 April 2019
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 8 August 2018
Resolved
Make wire run on starboard side between #1 and #2 void and #2 and #3 water/Smoke tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2018
Resolution: wire run on starboard side between #1 and #2 void and #2 and #3 has been made water/Smoke tight
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 August 2018
Resolved
Replace/reseal transducer gasket starboard side.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2018
Resolution: transducer has been removed cleaned up and reinstalled with new gaskets and sealant, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018
Resolved
Repair port fuel tank shut off valve.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2018
Resolution: vessel has repaired port fuel tank shut off valve tested all sat
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2017
Resolved
Provide up to date nautical charts
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 9 August 2017
Resolution: Onboard, sat.
Communications › Radio Communications › EPIRB
Issued 1 June 2017
Resolved
Hydrostatic release unit for EPIRB expired. Provide valid HRU.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2017
Resolved 1 June 2017
Resolution: Cleared during inspection.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 June 2017
Resolved
Crew not present during inspection, will conduct drills within 2 weeks with CG MIs.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 9 August 2017
Resolution: Observed, sat.
Lifesaving › Hand Flares › Quantity
Issued 25 July 2016
Resolved
Only 4 hand flares were onboard out of the required 6. Provide 2 additional flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 25 July 2016
Resolution: Master purchased additional flares after inspection.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 July 2016
Resolved
Onboard alcohol test strips were expired. Replace both test strips.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 25 July 2016
Resolution: Master purchased alcohol test strips after inspection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 July 2016
Resolved
Bilge high level alarm panel not functioning properly. Despite dry bilge, void 3 continuously in alarm state. Demonstrate proper operation of the bilge high level alarm system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 8 August 2016
Resolution: Attended vessel to witness testing of new bilge monitoring system, all sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 May 2016
Resolved
Vessel did not have hull/ISE exam conducted by drop dead date.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2016
Resolved 14 May 2016
Resolution: vessel had sat drydock and ise
Communications › Radio Communications › EPIRB
Issued 11 August 2014
Resolved
Properly renew EPIRB battery and renew expired hydro static release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2015
Resolved 26 May 2015
Resolution: Owner purchased a new EPIRB and registered it with NOAA.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 August 2014
Resolved
Conduct underway tests and sea trials and emergency drill in the presence of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 1 May 2015
Resolved 26 May 2015
Resolution: Conducted satisfactory man overboard, fire, and abandon ship drills.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 January 2012
Resolved
Have onboard current FCC safety certificate.
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 8 June 2012
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 January 2012
Resolved
Create company drug and alcohol policy and provide/post hot line number for your employees.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 8 June 2012
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 25 January 2012
Resolved
Post lifejacket donning placard visible to passengers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 8 June 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 January 2012
Resolved
Provide proper float light for vessels lifebuoy w/line and corrosion resistant clip. Prior to carrying passengers at night or reduced visibility.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2012
Resolved 8 June 2012
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 January 2012
Resolved
Install metallic bulkhead fitting were rubber hose penetrates the collision bulkhead.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 8 June 2012
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 25 January 2012
Resolved
Have onboard the 2012 current tables.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 June 2012
Resolved 8 June 2012