MAURY USCG vessel records
← All vessels

NEW ACCORD

NEW ACCORD is a 2008 tank ship. The Coast Guard has recorded 5 inspections since 2017, most recently in August 2019, along with 1 deficiency.

Records from 2017 to 2019. Most recent: inspection, 15 August 2019.

Built
2008
Last inspected
15 August 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 August 2019
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9487172
1015908
Flag
LIBERIA
Maury page id
psix-1015908

Documentation record

Tonnage as PSIX records it61736 - Convention (Subpart B), Gross Ton
61736 - Regulatory (Subpart C or D), Gross Ton
32726 - Regulatory (Subpart C or D), Net Ton
109804 - Dead Weight, Ton
129687 - Displacement, Ton
32726 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

15 August 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6783093
15 May 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6684796
15 April 2019 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6662734
18 August 2018 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6504025
15 August 2017 Deficiency Check · COC-TVE Renew · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6235826

Deficiency record · 1

Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 15 August 2017 Resolved
0745-Fire Fighting-The Main Inlet and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The Closing device for the emergency generator supply intake failed to close properly.- SOLAS74(2004cons)II-2/5.2.1.1 [40a]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 August 2017
Resolution: Repairs completed. Received class report attesting to repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.