MOBRO II

Built
1969
Last inspected
14 November 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 14 November 2024
Operational controls None recorded without a removal date
Years with a record 7 calendar years (1999–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCM5368
101640
Flag
UNITED STATES
Maury page id
psix-101640

Documentation record

Registered dimensions (L × B × D)43.6 ft × 15.0 ft × 4.6 ft
Registered tonnagegross 25 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDIESEL SHIPBUILDING CO · JACKSONVILLE · built 1969
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 6 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 9 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

14 November 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8034834
4 November 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8029488
14 November 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7594333
25 August 2021 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7289076
27 July 2021 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7269269
17 April 2014 Administration
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4838157
30 March 2012 Administration
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4275476
18 November 2004 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2243755
25 March 1999 Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1114155

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 November 2024 No resolution recorded
Credit DDE & ISE Worklist Items. 1. Fwd Port Hull Plating iwo keel, wasted Crop & Renew, 3/8 inch plate, 115 inches by 26 inches. 2. Fwd Stbd Hull Plating iwo keel, wasted Crop & Renew, 3/8 inch plate, 140 inches by 30 inches. 3. Stbd Hull Plating iwo keel, wasted Crop & Renew, 3/8 inch plate, 46 inches by 20 inches. 4. Aft stack deck wasted & holed, crop & renew, 1/4 inch, 12inches by 18 inches. 5. Stack Deck iwo engine room exterior hatch wasted with multiple holes. Stack deck to be removed and renewed. 6. 2nd/bosen hole, stbd side overhead two holes iwo of deck bit. Crop & renew, with repairs to good material. 7. 2nd/bosen compartment, centerline, all lower/bottoms of transvers shell frames (holed & wasted. Crop & Renewal, to good material. 8. Engine room, lower bottom transvers frame iwo shaft packing gland damaged. Crop and renew frame. 9. Wheel House, portside window holed. Renew window. 10. Two Sea Valves. Not open, removed valve bonnets and open for inspection. 11. Fwd & Aft engine room wtd gaskets, damaged and unable to property seal. Renew gaskets. 12. 3/8 inch hull plating two areas of localized pitting, max depth 1/8 inch. Clad weld or make proper repairs. 13. Port & Stbd Flanking Rudder bearings appear worn, with excessive movement. Provide rudder bearing clearance readings, for consideration. As of 30JUL2025 Company failed to complete Dry-dock and internal structural repairs. Activity closed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 November 2024 No resolution recorded
Vessel did not complete Dry Dock inspection by 31 AUG 2024. Complete Dry Dock prior to engaging in towing operations.
Condition: Invalid
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 November 2022 Resolved
Except as provided in paragraphs (d)(2) through (4) of this section, each towing vessel must carry the survival craft specified in Table 141.305 of this section, as appropriate for the towing vessel, in an aggregate capacity to accommodate the total number of individuals onboard. Vessel did not have IBA on board. 46 CFR 141.305 (d) (1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Batteries were dead and hooked to a charging unit. 46 CFR 143.205 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 November 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Exhuast leak found in the engine room. 46 CFR 143.205 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 November 2022 Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either: (1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or (2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or (3) Another suitable steel container that provides an equivalent level of protection. Fuel canisters were stored in a plastic container not secured to the vessel. 46 CFR 142.225 (c) (1)-(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 November 2022 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi-portable extinguisher was ratchet strapped to pilot house bulkhead. 46 CFR 142.230 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 November 2022 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Engine room watertight door gasket material was painted over. 46 CFR 140.610 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2022 Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Engine room terminal block not covered and engine room lighting found hanging by electrical wires. 46 CFR 143.410 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 November 2022 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel. Main engine rotating machinery did not have guard in place. 46 CFR 144.820
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 November 2022 Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. On a new vessel, each pipe that contains vapor, gas, or liquid that has a temperature exceeding 150 °F (65.5 °C) which is within reach of personnel must be insulated where necessary or otherwise guarded to prevent injury. Turbo Charger lagging was not secured. 46 CFR 144.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 November 2022 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM; (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM; (4) Auxiliary generator engine cooling water temperature. Engines did not have local guages as required. 46 CFR 143.230 (c)(1)(3)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2022
Resolved 21 November 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 November 2022 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Pin broke off at shut off valve location. 46 CFR 143.260 (b)
Action required: 10 - Deficiency Rectified
Resolved 14 November 2022
Resolution: Fixed while on board for exam.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 November 2022 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. Found numerous items in first aid kit expired. 46 CFR 140.435
Action required: 10 - Deficiency Rectified
Resolved 14 November 2022
Resolution: Resolved while on board for exam.