← All vessels
CHANTAL
CHANTAL is a 2009 tank ship. The Coast Guard has recorded 22 inspections since 2009, most recently in April 2026, along with 10 deficiencies and 5 operational controls.
Records from 2009 to 2026. Most recent: inspection, 11 April 2026.
- Built
- 2009
- Last inspected
- 11 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9382982 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8WQ3
1016553
Flag
LIBERIA
—
Maury page id
psix-1016553
Inspections, by type
…with no type recorded6
Years with a record
16 calendar years (2009–2026)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it41676 - Convention (Subpart B), Gross Ton
21792 - Convention (Subpart B), Net Ton
74329 - Dead Weight, Metric Ton
882735 - Displacement, Metric Ton
21792 - Convention (Subpart B), Net Ton
74329 - Dead Weight, Metric Ton
882735 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
11 April 2026
PSC B · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8345994
25 June 2025
COC-TVE Annual · PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8165123
12 April 2024
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7889546
6 January 2023
PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7616763
13 December 2021
PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7366292
10 December 2020
PSC B · Ballast Water Examination · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7096178
14 October 2019
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6832117
12 September 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6535291
3 May 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6405025
29 April 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6401502
20 July 2017
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6212128
22 November 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6046351
18 August 2016
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5976396
3 January 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5790112
13 July 2015
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5179600
5 March 2014
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4810751
15 May 2012
COC-TVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4304481
19 January 2011
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3928637
10 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3678265
19 July 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3539043
18 July 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3538539
13 July 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3533877
Deficiency record · 10
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 September 2018
Resolved
Condition of ship and its equipment shall be maintained to conform w/ provisions of present regulations to ensure the ship in all respects remain fit to proceed to sea w/o danger to ship or persons on board. Expansion bellows on IGS blowers were found cracked and severly worn. 74SOLAS(14) I/11(a)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 12 September 2018
Resolved
Condition of ship and its equipment shall be maintained to conform with provisions of present regulations to ensure the ship in all respects remain fit to proceed to sea without danger to ship or persons on board. PSCO disovered forward packing gland on stripping pump was leaking cargo. 74SOLAS(14) I/11(a)
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 January 2016
Resolved
ON EACH TANKER 10,000 GT OR MORE, THE DUAL RADAR SYSTEM BY THIS PART MUST HAVE A SHORT AND LONG RANGE CAPABILITY. "S" BAND RADAR WAS REPORTED INOPERABLE, IAW 33CFR164.37. IN ACCORDANCE..... SEE NARRATIVE FOR FULL DEF.
Lifesaving › Rescue Boat › Propeller Shaft
Issued 13 July 2015
Resolved
0610: Each survival craft shall be stowed in a state of continuous readiness. Starboard side rescue boat main drive shaft appears to be warped and binding when tested by hand. Excessive vibration during testing. 74 SOLAS (14) CONS III/13.1.3
Control Action: 17ac
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 13 July 2015
Resolved
1430: Manual starting of the emergency generator must be demonstrated as being effective during testing of the emergency generator, the generator shut off after two minutes of running not under load. 74 SOLAS (04) II-1/44 Control Action: 17ac
Fire Fighting › Structural - A Class Divisions › Doors
Issued 13 July 2015
Resolved
0799; The fire integrity of divisions shall be maintained at openings and penetrations. Multiple doors throughout the superstructure, including the stairwells and gallery are not properly self-closing as required, compromising the integrity of the boundaries. Additionally the drying room is been used as a storage locker, 74 SOLAAS (04 Con) II-2/9.1.3, 10C.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 July 2015
Resolved
2535; Transfer procedures must include the items listed in 33CFR155.750. Vessel's transfer procedures are missing communication, product description and identification of all involved personnel, 33CFR155.750, 10C.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 13 July 2015
Resolved
2510; Vessel must maintain a Ballast Water Management Plan and Bio-Fouling Plat that he crew shall follow. Vessel is using incorrect forms for training and sediment documentation and crew in not recording Bio-Fouling procedures, 33CFR155.2050(g), 10C.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 March 2014
Resolved
INOP X-Band radar LOD issued 05MAR2014
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 19 July 2009
Resolved
Vessel reported a loss of bridge main engine maneuvering control while transiting inbound to the Port of LA/LB. Vessel is to provide a technician's report and satisfactory class report attesting to the proper operation of the bridge main engine control system and final determination on the cause of the failure prior to departing the Port of LA/LB.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.