MAURY USCG vessel records Sign in
← All vessels

CHANTAL

CHANTAL is a 2009 tank ship. The Coast Guard has recorded 22 inspections since 2009, most recently in April 2026, along with 10 deficiencies and 5 operational controls.

Records from 2009 to 2026. Most recent: inspection, 11 April 2026.

Built
2009
Last inspected
11 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9382982 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1016553
Flag
LIBERIA
—
Maury page id
psix-1016553

Inspections, by type

…with no type recorded6
Years with a record 16 calendar years (2009–2026)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it41676 - Convention (Subpart B), Gross Ton
21792 - Convention (Subpart B), Net Ton
74329 - Dead Weight, Metric Ton
882735 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

11 April 2026 PSC B · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8345994
25 June 2025 COC-TVE Annual · PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8165123
12 April 2024 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7889546
6 January 2023 PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7616763
13 December 2021 PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7366292
10 December 2020 PSC B · Ballast Water Examination · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7096178
14 October 2019 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6832117
12 September 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6535291
3 May 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6405025
29 April 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6401502
20 July 2017 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6212128
22 November 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6046351
18 August 2016 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5976396
3 January 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5790112
13 July 2015 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5179600
5 March 2014 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4810751
15 May 2012 COC-TVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4304481
19 January 2011 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3928637
10 February 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3678265
19 July 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3539043
18 July 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3538539
13 July 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3533877

Deficiency record · 10

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 September 2018 Resolved
Condition of ship and its equipment shall be maintained to conform w/ provisions of present regulations to ensure the ship in all respects remain fit to proceed to sea w/o danger to ship or persons on board. Expansion bellows on IGS blowers were found cracked and severly worn. 74SOLAS(14) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 September 2018
Resolution: Received satisfactory class report from ABS attesting to the replacement and operations of the replaced expansion bellows.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 12 September 2018 Resolved
Condition of ship and its equipment shall be maintained to conform with provisions of present regulations to ensure the ship in all respects remain fit to proceed to sea without danger to ship or persons on board. PSCO disovered forward packing gland on stripping pump was leaking cargo. 74SOLAS(14) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 September 2018
Resolution: Received satisfactory class report from ABS attesting to renewing the packing gland on the stripping pump and properly functioning.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 January 2016 Resolved
ON EACH TANKER 10,000 GT OR MORE, THE DUAL RADAR SYSTEM BY THIS PART MUST HAVE A SHORT AND LONG RANGE CAPABILITY. "S" BAND RADAR WAS REPORTED INOPERABLE, IAW 33CFR164.37. IN ACCORDANCE..... SEE NARRATIVE FOR FULL DEF.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 January 2016
Resolution: RECEIVED REPORT FROM VESSEL'S CLASS, ABS, THAT THEY ATTENDED THE VESSEL ON 06JAN2016 IN REGARDS TO THE DOWN S-BAND RADAR. A NEW MODULATION TRANSFORMER, FURUNO, MODEL NO. RT9273, WAS INSTALLED. THE S-BAND RADAR FULLY OPERATIONAL AND CONSIDERED SATISFACTORY
Lifesaving › Rescue Boat › Propeller Shaft
Issued 13 July 2015 Resolved
0610: Each survival craft shall be stowed in a state of continuous readiness. Starboard side rescue boat main drive shaft appears to be warped and binding when tested by hand. Excessive vibration during testing. 74 SOLAS (14) CONS III/13.1.3 Control Action: 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2015
Resolved 14 July 2015
Resolution: Corrected to the satisfaction of the attending Classification Surveyor.
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 13 July 2015 Resolved
1430: Manual starting of the emergency generator must be demonstrated as being effective during testing of the emergency generator, the generator shut off after two minutes of running not under load. 74 SOLAS (04) II-1/44 Control Action: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2015
Resolved 14 July 2015
Resolution: Corrected to the satisfaction of the attending Classification Surveyor.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 13 July 2015 Resolved
0799; The fire integrity of divisions shall be maintained at openings and penetrations. Multiple doors throughout the superstructure, including the stairwells and gallery are not properly self-closing as required, compromising the integrity of the boundaries. Additionally the drying room is been used as a storage locker, 74 SOLAAS (04 Con) II-2/9.1.3, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2015
Resolved 13 July 2015
Resolution: Spoke with the [name withheld] and Chief Engineer about adjusting the doors and maintenance of same.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 July 2015 Resolved
2535; Transfer procedures must include the items listed in 33CFR155.750. Vessel's transfer procedures are missing communication, product description and identification of all involved personnel, 33CFR155.750, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2015
Resolved 13 July 2015
Resolution: Reviewed the procedures with the Captain and [name withheld].
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 13 July 2015 Resolved
2510; Vessel must maintain a Ballast Water Management Plan and Bio-Fouling Plat that he crew shall follow. Vessel is using incorrect forms for training and sediment documentation and crew in not recording Bio-Fouling procedures, 33CFR155.2050(g), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2015
Resolved 13 July 2015
Resolution: Discussed items with the [name withheld] and Chief Engineer.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 March 2014 Resolved
INOP X-Band radar LOD issued 05MAR2014
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2014
Resolved 11 March 2014
Resolution: 11MAR14: Received tech report stating the vessel replaced a worn magnetron and is fully operational.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 19 July 2009 Resolved
Vessel reported a loss of bridge main engine maneuvering control while transiting inbound to the Port of LA/LB. Vessel is to provide a technician's report and satisfactory class report attesting to the proper operation of the bridge main engine control system and final determination on the cause of the failure prior to departing the Port of LA/LB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2009
Resolution: Class report received attesting to the correct operational control of the MDE.

Ownership record