← All vessels
OWL 2
OWL 2 is a 2008 tank ship. The Coast Guard has recorded 14 inspections since 2011, most recently in December 2023, along with 9 deficiencies and 5 operational controls.
Records from 2011 to 2023. Most recent: operational control imposed, 15 December 2023.
- Built
- 2008
- Last inspected
- 15 December 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9439307 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7KV5
1016709
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1016709
Inspections, by type
…with no type recorded5
Years with a record
5 calendar years (2011–2023)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8539 - Convention (Subpart B), Gross Ton
4117 - Convention (Subpart B), Net Ton
13020 - Dead Weight, Ton
17472 - Displacement, Ton
4117 - Convention (Subpart B), Net Ton
13020 - Dead Weight, Ton
17472 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
15 December 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7839349
14 February 2023
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7636437
14 February 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7636749
14 February 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7636878
10 February 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7635035
28 September 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7568067
11 July 2022
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7503731
22 June 2022
PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7483765
22 January 2022
PSC A · COC-CHEM & TVE Renew · Appeal
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7380641
21 January 2022
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7383611
9 June 2018
COC-CHEM Renew · Administrative Inspection · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6431999
18 August 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4959030
7 August 2014
COC-CHEM & TVE Renew · COE-Dockside · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4943680
8 July 2011
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4074146
Deficiency record · 9
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 22 June 2022
Resolved
Machinery and boilers shall be of a good design and construction adequate for the service when they are intended. The oily water seperator content high, main engine fuel leakage, oil mist detector and aux boiler shutdown alarms are inoperable.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 January 2022
Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The objective nature of the deficiencies 02, 03, and 04 demonstrate the vessel is not being maintained to international standards, bringing into question the validity of the safety management certificate issued pursuant to the ISM code. An external audit is required to be submitted prior to departure from port.
74 SOLAS (20) IX/3.1 ISM A/10.1
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 22 January 2022
Resolved
There shall be available at all times, while the ship is at sea, a supply of electrical energy sufficient to charge any batteries used as part of a reserve source or sources of energy for the radio installations. PSCO found Vessel's installed means of battery charging inoperable. [name withheld] stated to PSCO that Flag Administration and Class Society were not notified of charger failure nor of temporary repairs as required per Safety Management System.
74 SOLAS (20)IV/13.1
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 January 2022
Resolved
The high-level alarm system required under 15.19.6 shall be independent of the overflow-control system required by 15.19.7 and shall be independent of the equipment required by by 13.1. PSCO witnessed high level alarms for 2S, 3P, 3S and 6S tanks not activating properly during functional test of alarms float switch with vessel’s [name withheld] found ship's log indicating satisfactory tests completed the prior day.
74 SOLAS (20) VII/10
IBC 15.19.5
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 January 2022
Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Two emergency escape doors on "B" deck were unable to be opened in direction of escape route from accommodation space to the exterior of the vessel. PSCO discovered both door handles were missing on the interior side and one came off while attempting to open it from the outside.
74 SOLAS (09) II-2/13.1.2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 January 2022
Resolved
Each vapor connection flange must have a permanent stud projecting outward that is at least 1 inch long. While conducting cargo deck walk with [name withheld] the PSCO discovered multiple flanges without the required permanently affixed flange stud.
46 CFR 39.2001(j)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 January 2022
Resolved
Satisfactory means for safe passage required by regulation 25-1 shall be provided for the protection of the crew used in the essential operation of the ship. While conducting cargo deck walk with [name withheld] the PSCO discovered the middle course between the stanchions on port bow edge broken along with wasted supports for steel grating near the starboard anchor windlass.
ICLL(88) I/25(4)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 January 2022
Resolved
Cabin doors in "B" class divisions shall be of self-closing type. While transiting through vessel’s crew mess entrance, PSCO observed a “B” class door unable to fully self-close.
74 SOLAS (09) II-2/9
Deck/Cargo › Cargo Stowage › General
Issued 9 June 2018
Resolved
1999- Other(MARPOL ANNEX II)- Cargo samples in stowage shall be cell-divided in order to avoid shifting of the bottles at sea. PSCO's observed dozens of cargo samples piled on top of other sample bottles. They werent stored securely and were not cell-divided. 74SOLAS(14) VII/10.1 REF. IBC CODE 16.5.2.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National