PHOEBE is a freight ship. The Coast Guard has recorded 15 inspections since 2009, most recently in April 2021, along with 12 deficiencies and 1 operational control.
Records from 2009 to 2021. Most recent: inspection, 7 April 2021.
- Built
- Not recorded
- Last inspected
- 7 April 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9293765 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5WO7
1017788
Flag
LIBERIA
—
Maury page id
psix-1017788
Inspections, by type
…with no type recorded1
Years with a record
8 calendar years (2009–2021)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it90449 - Convention (Subpart B), Gross Ton
59328 - Convention (Subpart B), Net Ton
106936 - Dead Weight, Metric Ton
134888 - Displacement, Metric Ton
59328 - Convention (Subpart B), Net Ton
106936 - Dead Weight, Metric Ton
134888 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
7 April 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7170462
5 April 2021
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7167971
12 January 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7123370
26 October 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7084240
21 October 2020
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7081854
10 August 2020
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7028968
31 July 2020
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7021141
28 January 2020
Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6898107
30 October 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6845156
26 December 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6328959
19 December 2016
Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6059951
1 February 2011
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3897044
2 February 2010
Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3674383
4 July 2009
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3522046
2 July 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3521520
Deficiency record · 12
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2020
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed multiple corroded and damaged exterior light fixtures. Additionally, PSCO observed 01 exterior light casing was cracked. Lighting fixture on stbd, aft fantail was corroded causing the light to hang by only one side of the fixture and its electrical cables. 74 SOLAS (04) II-1/40.1.3
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 28 January 2020
Resolved
It is required that ships maintain the upkeep of essential warning notices as well as the state of repair or remote control equipment such as alarms and safety devices. The door release for the fish reefer was inoperable from the inside.
ILO 147 pg.46
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2020
Resolved
Every steam pipe and fitting connected thereto which steam passes through shall be so designed constructed and installed to withstand the max working stresses to which it may be subjected. A steam leak was visible near the MDE HFO filter.
74 SOLAS 14/ II/ 1-33
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 October 2019
Resolved
Cargo ships of 1000 GT shall be provided with two independently driven fire pumps. The vessels main fire pump has been taken out of service due to failure of its mechanical seal.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 October 2019
Resolved
Prevention of ignition of combustible or flammable liquids a means shall be provided to control leaks. Lube oil piping on #2 and #5 are leaking due to failure of its o-rings
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 October 2019
Resolved
After a survey has been completed, no change shall be made in the machinery, equipment, and any other items covered by the survey. Upon engine room walk through, PSCO was advised all equipment operational. During walk through, #1 gen actively leaking substantial amount of jacket cooling water and #4 gen currently out of service due to seizure of lube oil pump. Still under investigation with the ship's crew and no notification to flag or class have been made.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 26 December 2017
Resolved
Enclosed space entry and rescue drills should be planned and conducted in a safe manner. Vessel has only one litter, which is rigid and cannot fit into all enclosed spaces. Vessel's crew has been using a harness for those spaces, providing no spinal support for potential injured personnel. Cite: 74SOLAS(14)III/Reg 19.3.6, Action: 40ac.
Operations/Management › Vessel Activity › Other
Issued 26 December 2017
Resolved
Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position with the valve protection cap in place. Oyxgen and acetylene bottles in the lockers are secured in a position without proper brackets and are on the deck. Cite: 46CFR147.60(b), Action: 40ac.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 December 2017
Resolved
Oil filtering equipment refered to in Paragraph 2 of this regulation shall comply with Paragraph 6 of this regulation. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. Onboard calibration for 107.49 is dated 24SEP2012 and past five year anniversary. Cite: MARPOL Annex I, Reg. 14.7, MEPC 107(49), and MOC Policy No. 04-13 Rev. 1. Action: 40ac.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 December 2016
Resolved
In spaces where penetration of oil products is possible, the surface of insulation shall be impervious to oil or oil vapors. The lagging on fuel lines for Diesel generators #1 and #2 were weathered and oil soaked. SOLAS74(2004 CONS.) II-2/4.4.3 40ac CODE:1470
Lifesaving › Lifeboat › Carriage Requirement
Issued 1 February 2011
Resolved
0610: Lifeboats shall be stowed in a continuous state of readiness on both lifeboats the launching arrangement located inside the boat was not inside the lifeboat. In addition there is no plan or checklist instructing the crew to replace the launching arrangement before departure. 70ab
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 February 2011
Resolved
0715: Fixed fire detection alarm system shall be capable of immediate operation at all times. Two smoke detectors in the garbage incinerator room were found covered by cloth and plastic. 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.