MAURY USCG vessel records
← All vessels

VIGOR SW

VIGOR SW is a 2009 freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in August 2022, along with 11 deficiencies and 1 operational control.

Records from 2017 to 2022. Most recent: inspection, 30 August 2022.

Built
2009
Last inspected
30 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 August 2022
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9383508
1018129
Flag
PANAMA
Maury page id
psix-1018129

Documentation record

Tonnage as PSIX records it20236 - Convention (Subpart B), Gross Ton
39678 - Displacement, Ton
32227 - Dead Weight, Ton
10947 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

30 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7547283
8 July 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7492491
21 January 2021 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7127984
16 December 2020 PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7111601
30 July 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6495316
19 June 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6449570
20 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6215557
1 July 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6184258

Deficiency record · 11

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 July 2022 Resolved
Guard rails fitted on superstructure and freeboard decks shall have at least three courses. The opening below the lowest courses of the guard rails shall not exceed 230mm. PSCO observed broken course on starboard midship guard rail, exceeding the 230mm requirement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2022
Resolved 30 August 2022
Resolution: RECEIVED CLASS SURVEY FROM NKK ATTESTING TO RECTIFICATION OF DEFICIENCY.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 December 2020 Resolved
09298 - WORKING CONDITIONS - THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGUARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO NOTED DETERIORATED FIRE BRICK INSULATION INSIDE THE INCINERATOR CAUSING DANGER TO PERSONS ON BOARD IN REGARDS TO HOT SURFACES. 74SOLAS(04)II-1/26.1 - 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2021
Resolved 24 December 2020
Resolution: Incinerator brick replaced to satisfaction of NKK
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 December 2020 Resolved
07126 - FIRE SAFETY - MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO NOTED OIL ACCUMULATION INDICATING A LEAK ON THE FUEL DELIVERY LINES TO THE MAIN ENGINE. PSCO ALSO NOTED OIL ACCUMLATION ON FUEL OIL STRAINER FITTINGS CAUSED BY MAINTENANCE. 74SOLAS(04)II-2/4.1.1 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 December 2020
Resolution: CREW REPLACE 02 O-RINGS IN THE FUEL DELIVERY LINES TO THE INJECTORS AND CLEANED THE ACCUMULATED OIL ON THE STRAINER FILTERS TO THE SATISFACTION OF THE PSCO.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 December 2020 Resolved
03108 - VENTILATORS, AIR PIPES, CASINGS - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OF PERSONS ON BOARD. PSCO NOTED SEVERAL DECK STORAGE UNITS' EXHAUST AND INTAKE VENTILATION CLOSURES INOPERABLE DUE TO MISSING HARDWARE AND GASKETS. 74SOLAS(14)I/11(a)- 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 December 2020
Resolution: CREW REPLACED WORN GASKETS, WINGNUTS, AND ENSURE PROPER OPERATION OF CLOSURE DEVICES.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 July 2018 Resolved
CODE 1430-Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by administration with a stored energy capability of at least three consecutive starts. Primary means of starting emergency generator is non-operational due to expired battery. Cite-SOLAS14 CH II-1 44.2 Action Taken 17 C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2018
Resolved 9 August 2018
Resolution: Ship replaced batteries and sent photos of the new installation, as well as the old removed batteries.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 30 July 2018 Resolved
CODE2199- After any suvey of the ship has been completed. No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. Ships crew is using the aft peak tank as a sewage/gray water holding tank. The crew has two soft hoses connecting the gray water system to the aft peak tank. Cite-SOLAS 2009_CONS.ED) CHI 11(B) Action Taken 50AC
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 31 July 2018
Resolution: Administration approved hose removal and installation of hard piping to the tank.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 July 2018 Resolved
Code 0999- The machinery associated piping systems and fittings shall be so installed and protected as to reduce to a minimum any danger to persons onboard. Due regard being paid to hot surfaces. The outlet pipe for the NO.1 Generator flash cooler presents a signifigant safety hazard. The pipe currently lacks insulation or warning of a hot surface and is in the owrking area of the crew. CITE-74 SOLAS(14) II-1 26 Action Taken-50C
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 31 July 2018
Resolution: Piping wrapped with insulation and crew safety awareness updated.
01 - Certificates & Documentation › 013 - Documents › Declaration of AFS compliance
Issued 30 July 2018 Resolved
Code 2510- Vessel must maintain a Ballast Water Management Plan to include biofouling that has been specifically developed for the vesel. The vessel currently does not have a Biofouling Management Plan or record book as required by Cite-33 CFR 151.2050 (G) reference IMO MEPC RES 207 (62) Action Taken-40 C
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2018
Resolved 16 December 2020
Resolution: Biofouling Managment plan reviewed and found satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to the sea without danger to the ship or persons on board. Exhaust ventilation for CO2 room is non-operational. Mesh opening has been painted closed and does not permit the passage of air. Cite-SOLAS 14 CHI-II Action Taken-50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 31 July 2018
Resolution: Mesh replaced with new material.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 July 2018 Resolved
Means Shall be provided to control leaks of flammable liquids; there was asignifigacant oil accumulation under #1 Generator posing major fire hazard. Cite-SOLAS 14, CH II-2 4.1.1 Action Taken-10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 July 2018
Resolved 30 July 2018
Resolution: Vsl cleaned up oil.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 July 2017 Resolved
0936-Steering Gear- The steering gear compartments shall be provided with suitable arrangements to ensure working access to steering gear. These arrangements shall include handrails and gratings or other nonslip surfaces. Steering gear room had no gratings or non-slip arrangements. 74 SOLAS (04 Cons.) II-1/29.13.2
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 20 July 2017
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.

Ownership record