← All vessels
VIGOR SW
VIGOR SW is a 2009 freight ship. The Coast Guard has recorded 11 inspections since 2009, most recently in August 2022, along with 11 deficiencies and 1 operational control.
Records from 2009 to 2022. Most recent: inspection, 30 August 2022.
- Built
- 2009
- Last inspected
- 30 August 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9383508 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EXV3
1018129
Flag
PANAMA
—
Maury page id
psix-1018129
Inspections, by type
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it20236 - Convention (Subpart B), Gross Ton
39678 - Displacement, Ton
32227 - Dead Weight, Ton
10947 - Convention (Subpart B), Net Ton
39678 - Displacement, Ton
32227 - Dead Weight, Ton
10947 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
30 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7547283
8 July 2022
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7492491
21 January 2021
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7127984
16 December 2020
PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7111601
30 July 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6495316
19 June 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6449570
20 July 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6215557
1 July 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6184258
31 January 2012
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4235657
27 January 2012
PII Safety Exam · ISPS I Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4232806
1 July 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3514537
Deficiency record · 11
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 July 2022
Resolved
Guard rails fitted on superstructure and freeboard decks shall have at least three courses. The opening below the lowest courses of the guard rails shall not exceed 230mm. PSCO observed broken course on starboard midship guard rail, exceeding the 230mm requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 December 2020
Resolved
09298 - WORKING CONDITIONS - THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGUARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO NOTED DETERIORATED FIRE BRICK INSULATION INSIDE THE INCINERATOR CAUSING DANGER TO PERSONS ON BOARD IN REGARDS TO HOT SURFACES. 74SOLAS(04)II-1/26.1 - 50ac
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 December 2020
Resolved
07126 - FIRE SAFETY - MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO NOTED OIL ACCUMULATION INDICATING A LEAK ON THE FUEL DELIVERY LINES TO THE MAIN ENGINE. PSCO ALSO NOTED OIL ACCUMLATION ON FUEL OIL STRAINER FITTINGS CAUSED BY MAINTENANCE. 74SOLAS(04)II-2/4.1.1 - 10c
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 December 2020
Resolved
03108 - VENTILATORS, AIR PIPES, CASINGS - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OF PERSONS ON BOARD. PSCO NOTED SEVERAL DECK STORAGE UNITS' EXHAUST AND INTAKE VENTILATION CLOSURES INOPERABLE DUE TO MISSING HARDWARE AND GASKETS. 74SOLAS(14)I/11(a)- 10c
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 July 2018
Resolved
CODE 1430-Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by administration with a stored energy capability of at least three consecutive starts. Primary means of starting emergency generator is non-operational due to expired battery. Cite-SOLAS14 CH II-1 44.2 Action Taken 17 C
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 30 July 2018
Resolved
CODE2199- After any suvey of the ship has been completed. No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. Ships crew is using the aft peak tank as a sewage/gray water holding tank. The crew has two soft hoses connecting the gray water system to the aft peak tank. Cite-SOLAS 2009_CONS.ED) CHI 11(B) Action Taken 50AC
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 July 2018
Resolved
Code 0999- The machinery associated piping systems and fittings shall be so installed and protected as to reduce to a minimum any danger to persons onboard. Due regard being paid to hot surfaces. The outlet pipe for the NO.1 Generator flash cooler presents a signifigant safety hazard. The pipe currently lacks insulation or warning of a hot surface and is in the owrking area of the crew. CITE-74 SOLAS(14) II-1 26 Action Taken-50C
01 - Certificates & Documentation › 013 - Documents › Declaration of AFS compliance
Issued 30 July 2018
Resolved
Code 2510- Vessel must maintain a Ballast Water Management Plan to include biofouling that has been specifically developed for the vesel. The vessel currently does not have a Biofouling Management Plan or record book as required by Cite-33 CFR 151.2050 (G) reference IMO MEPC RES 207 (62) Action Taken-40 C
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to the sea without danger to the ship or persons on board. Exhaust ventilation for CO2 room is non-operational. Mesh opening has been painted closed and does not permit the passage of air. Cite-SOLAS 14 CHI-II Action Taken-50AC
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 July 2018
Resolved
Means Shall be provided to control leaks of flammable liquids; there was asignifigacant oil accumulation under #1 Generator posing major fire hazard. Cite-SOLAS 14, CH II-2 4.1.1 Action Taken-10C
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 July 2017
Resolved
0936-Steering Gear- The steering gear compartments shall be provided with suitable arrangements to ensure working access to steering gear. These arrangements shall include handrails and gratings or other nonslip surfaces. Steering gear room had no gratings or non-slip arrangements. 74 SOLAS (04 Cons.) II-1/29.13.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.