HYUNDAI SINGAPORE is a freight ship. The Coast Guard has recorded 15 inspections since 2017, most recently in January 2026, along with 11 deficiencies and 1 operational control.
Records from 2017 to 2026. Most recent: operational control imposed, 9 January 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it74651 - Convention (Subpart B), Gross Ton 107492 - Displacement, Metric Ton 80157 - Dead Weight, Metric Ton 43151 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
9 January 2026Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8293749
5 January 2026Vessel Attendance · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8288361
21 July 2023PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7748321
26 July 2022PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7516434
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 9 January 2026Resolved
To assist in casualty investigations, ships, when engaged on international voyages... shall be fitted with a voyage data recorder (VDR). Vessel reported that the VDR is inoperable and is not recording rudder movements.
74 SOLAS (20) V/20.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2026
Resolution: Vessel sent in tech report and repair from Mackey Marine attesting to repairs of VDR. Vessel is cleared to depart.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 18 February 2021Resolved
The company should establish procedures, plans, and instructions including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship and protection of the environment. PSCO observed numerous areas not being followed within SMS procedures in regards to storage of CO2 bottles, securing of engineroom skylight hatch, and worn/missing lagging the engine room. Due to the above objective evidence the PSCO questions the adequacy of the implementation of the vessels safety management system, an external audit is recommended to be conducted within 30 days by the flag state. 74SOLAS(14) IX/5 ISM PART A/7 50bc
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2021
Resolved 17 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 February 2021Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be so installed and protected as to reduce to a minimum any danger to persons on board due regard being paid to moving parts, hot surfaces, and other hazards. PSCO observed exhaust leak on maine diesel engine exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2021
Resolved 17 March 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 July 2018Resolved
THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ONBOARD. VESSEL SUFFERED FUEL LEAK ON MAIN PROPULSION ENGINE. 74SOLAS(14)II-2/4.2.2 -60ac-
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 July 2018
Resolution: RECEIVED SATISFACTORY CLASS REPORT ATTESTING TO THE EFFECTIVE REPAIR OF THE MAIN PROPULSION ENGINE AND PROPER CLEAN-UP OF FUEL-OIL IN THE ENGINE ROOM.
Engineering › Lubricating Oil Service System › Purifier
Issued 6 January 2018Resolved
The arrangements for the storage, distribution and utilization of fuel oil shall be such as to ensure the safety of the ship and persons aboard. PSCO witnessed excessive leaking from multiple sources from the purifier room. Solas 74 (14) II-2/4.2.2 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2018
Resolution: Recieved satisfactory class report attesting to the corrected issues.
The arrangements for the storage, distribution and utilization of oil used in a pressure lubrication system shall be such to ensure the safety of the ship and persons onboard. The PSCO discovered excessive leaking throughout the main engine cylinder lubrication system. Solas 74 (2014) II-2/4.2.3 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2018
Resolution: Recieved satisfactory class report attesting to the repairs conducted.
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 January 2018Resolved
Each emergency generating sets arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least three consecutive starts. Emergency generator failed to start as intended on battery mode. Solas 74 (2004) II-1/44.2 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2018
Resolved 6 January 2018
Engineering › Fuel Oil Service System › Heater
Issued 6 January 2018Resolved
The machinery, boilers, and other pressure vessels, associated piping systems shall be designed and constructed for the service intended and installed to reduce any danger to a minimum to persons onboard. Steamline for the M/E F.Oil heater is leaking. Solas 74 (2004) II-1/26.1 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2018
Resolved 6 January 2018
Electrical › Electric Generation Source (service) › Generator
Issued 13 November 2017Resolved
1430 - AUXILIARY MACHINERY - Electrical installations shall be such that all electrical auxiliary
services necessary for maintaining the ship in normal operational
and habitable conditions will be ensured without recourse to the
emergency source of electrical power. Vessel experienced a loss of
power while inbound to port. 74 SOLAS (04) II-1/40.1.1 -60ac-
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 14 November 2017
Resolution: RECEIVED SATISFACTORY CLASS REPORT.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 January 2017Resolved
SHIPS SHALL BE MAINTAINED IN COMPLIANCE WITH STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. SALT WATER COOLER PIPING WAS FOUND WASTED IN MULTIPLE AREAS. ADDITIONALLY, MULTIPLE SOFT PATCHES WERE FOUND ON SALT WATER PIPING. 74SOLAS(04)II-I/3-1 -40AC- 1499
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 January 2017
Resolution: Received e-mail with scanned LR classification society survey report #BUS 1730040 from agent stating deficiency issued from Activity #6067209 has been rectified. Survey report states: fresh water cooler sea water inlet piping was removed and renewed.
Lifesaving › Lifebuoys › Immediately Available
Issued 6 January 2017Resolved
LIFEBUOYS SHALL BE STOWED AS TO BE CAPABLE OF BEING RAPIDLY CAST LOOSE, AND NOT PERMANENTLY SECURED IN ANY WAY. LIFEBUOY LIGHTS FOUND SECURED IN HOUSING BOX RESTRICTING RELEASE. 74 SOLAS(14)III/7.1.1.2 -10C- 0650
Action required: 705 - Other - as specified
Resolved 6 January 2017
Resolution: Crew members removed doors off of enclosures for all lighted life rings. Corrected on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.