Records from 2017 to 2026. Most recent: inspection, 27 July 2026.
Documentation record
Tonnage as PSIX records it21193 - Convention (Subpart B), Net Ton
39895 - Convention (Subpart B), Gross Ton
34613 - Simplified, Gross Ton
27691 - Simplified, Net Ton
49507 - Dead Weight, Metric Ton
59374 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 9
27 July 2026
Administrative Inspection · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8447622
27 February 2026
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8314572
17 July 2025
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8178874
18 November 2024
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8033409
1 August 2024
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7972090
1 August 2024
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7976030
20 May 2024
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7913636
2 November 2023
PSC A · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7815655
1 November 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6295596
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2026
Resolved
IN ADDITION TO THE REQUIREMENTS CONTAINED ELSEWHERE IN THE PRESENT REGULATIONS, SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. PSCO OBSERVED LEAK IN MAIN DIESEL ENGINE WATER COOLER.
74SOLAS(20)II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2026
Resolution: PSCO verified renewal of MDE raw water piping follow RO attendance and operational testing.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 27 February 2026
Resolved
ALL SHIPS OF 300 GROSS TONNAGE AND UPWARDS... IN ADDITION TO MEETING THE REQUIREMENTS OF PARAGRAPH 2.2, BE FITTED WITH:...A 9GHz RADAR, OR OTHER MEANS TO DETERMINE AND DISPLAY THE RANGE AND BEARING OF RADAR TRANSPONDERS. PSCO OBSERVED INOPERABLE X-BAND RADAR
74SOLAS(20)V/19.2.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2026
Resolution: PSCO verified repair of X-BAND RADAR following RO attendance. PSCO observed satisfactory operation of X-BAND RADAR.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 February 2026
Resolution: Deficiency corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of design and construction adequate for the service for which they are intended. While transiting into New Haven Harbor, the vessel suffered a reduction in propulsion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2024
Resolution: Class report submitted