MAURY USCG vessel records
← All vessels

SIEM DORADO

SIEM DORADO is a 2009 research vessel. The Coast Guard has recorded 2 inspections in 2020, along with 1 deficiency.

Records in 2020. Most recent: inspection, 15 June 2020.

Built
2009
Last inspected
15 June 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 June 2020
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9424508
1018618
Flag
BAHAMAS, THE
Maury page id
psix-1018618

Documentation record

Tonnage as PSIX records it4869 - Convention (Subpart B), Gross Ton
1616 - Convention (Subpart B), Net Ton
4213 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

15 June 2020 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6977017
13 May 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6952461

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 June 2020 Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard due reguard paid to moving parts, hot surfaces and other hazards. Incinerator exhaust fan failed, leading to a fire, rendering the incinerator inoperable. 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 30 June 2020
Resolution: Satisfactory class report has been recieved and reviewed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.