OCEAN BREEZE is a tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in November 2025, along with 11 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 25 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it30087 - Convention (Subpart B), Gross Ton 13325 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
25 November 2025Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8273235
21 November 2025Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8272051
30 July 2025COC-CHEM & TVE Annual · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8197643
12 September 2024COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7997743
16 December 2023Deficiency Check · Administrative Inspection
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 July 2025Resolved
The condition of the ship and its equipment shall be mantained to conform with the provisions of the present regulations. PSCO observed 02 wear detection switches disconnected and inoperable on power packs 03 and 04.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2025
Resolved 14 August 2025
Resolution: Submitted class report of re-installed wear detection sensors.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 July 2025Resolved
The condition of the ship and its equipment shall be mantained to conform with the provisions of the present regulations. PSCO observed missing limit switch connection on power pack 03 suction valve
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2025
Resolved 14 August 2025
Resolution: Submitted class report of re-installed limit switch for suction line valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 September 2024Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers or in compartments assigned principally to accumulator batteries, in part paint lockers, acetylene stores or similar spaces unless the administration is satisfied that such equipment is appropriately certified for safe usage in the dusts, vapors or gases likely to be encountered. PSCO observed 04 lights (explosion proof) that were cracked or otherwise damaged.
74SOLAS(04)II-1/45.10.4
40(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2024
Resolution: vessel submitted class report attesting to the replacements of the lights
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 12 September 2024Resolved
The oil record book part II shall be completed on each occasion, on a tank-to-tank basis if appropriate whenever any of the following cargo/ballast operations take place in the ship; discharge of water from slop tanks. PSCO observed 02 entries in the oil record book part II on 27JUL2024 and 13DEC2023 approximately 212(m3)difference from the ODME records.
MARPOL Annex I 36.2.7
10(c)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 12 September 2024Resolved
The company should ensure that all personnel involved in the companies SMS have an adequate understanding of the relevant rules, regulations, codes, and guidelines (6.4) The technical nature of the deficiencies listed above provide objective evidence of a serious failure of the implementation of the ISM code, and an internal audit of the vessels SMS focusing on the ODME operation, electrical maintenance, and testing/calibration of fixed gas detection is required.
74SOLAS(20)IX/3.1
ISM CODE 6.4
40(a)(c)
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2024
Resolution: Vessel submitted internal Audit report.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 September 2023Resolved
01 - 07101 - In addition to the requirements contained elsewhere to the present regulations, ships shall be designed, constructed and maintained in compliance with structural, mechanical and electrical requirements of a classification society. 74 SOLAS (14) II-1/3-1 - 15(a)(c).
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 16 December 2023
Resolution: Vessel submitted Class Report attesting to repairs.
Oil filtering equipment referred to in Regulation 14.2 shall comply with Regulation 14.6. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of effluent exceeds 15 PPM. During testing of the Oily Water System, PSCO observed the overboard solenoid valve was continuously energized regardless of the effluent PPM. When the PPM was increased above 15 PPM, the recirculating solenoid failed to energize and the overboard solenoid remained energized allowing the effluent above 15 PPM to be discharged. MARPOL (2017) Annex I/14.7 17 a c.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2019
Resolution: RECEIVED CLASS REPORT STATING THAT NO SPARE PART IS AVAILABLE. ISSUED SHORT TERM IOPP STATING THAT OWS 3-WAY SOLENOID IS TO BE FIXED BY 31DEC19 AND CAN NOT BE USED UNTIL FIXED.
Oil filtering equipment referred to in Regulation 14.2 shall comply with Regulation 14.6. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of effluent exceeds 15 PPM. PSCO observed the sample line from the OWS to the Oil Content Meter was not receiving effluent flow during the operational test. MARPOL (2017) Annex I/14.7 17 a c.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2019
Resolution: RECEIVED CLASS REPORT STATING THE SAMPLE LINE WAS FOUND OBSTRUCTED AND REPAIRED ACCORDINGLY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 December 2019Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Main engine fuel pump on cylinder number 6 is leaking fuel and is a fire hazard. 74 SOLAS (2004) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 December 2019
Resolution: RECEIVED CLASS REPORT STATING THE PUMP WAS OVERHAULED AND PUNCTURE VALVE WAS REPLACED BY NEEW SPARE AND ALL O-RINGS REPLACED AS NECESSARY. NO LEAKAGED OBSERVED.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 13 December 2019Resolved
For tankers of 20000 DWT and upwards, the protection for the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. The IG System shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. The crew was unable to calibrate the Inert Gas Generator O2 analyzer to verify O2% being delivered. Prove proper operation of the IG System and analyzer calibration prior to discharging a cargo in the United States that requires to be inerted. 74 SOLAS (2014) II-2/4.5.5.1.1. and FSS Code Ch 15.2.2.1.2.5.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 December 2019
Resolution: Received class report from LR stating the deficiency has been rectified.
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The internal offload release cable is inoperable rending the protected release capability ineffective of the starboard lifeboat. 74SOLAS(14CONS)III/20.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2016
Resolved 4 January 2016
Resolution: Repairs conducted to the satisfaction of class. See attached class report.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.