Records from 2016 to 2026. Most recent: inspection, 1 July 2026.
Inspection history · 14
1 July 2026
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8426784
23 March 2026
Administrative Inspection · COC-TVE Annual
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8330335
9 May 2025
COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8131718
2 August 2024
COC-TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7972929
19 May 2023
COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7686738
19 May 2022
COC-TVE Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7454492
20 May 2021
PSC B · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7201597
8 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7192310
21 February 2020
PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6908356
9 January 2019
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6602085
19 May 2018
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6418252
5 June 2017
COE-Offshore · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6152621
20 April 2016
ISPS II Exam · In-Service Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5858288
9 February 2016
COC-TVE Renew · PII Safety Exam · ISPS II Exam
Physical examination · Activities Europe · Activity 5811844
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2023
Resolved
In tankers electrical equipment... shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable by the Organization. There are 06 explosion-proof lights with cracked lenses, 05 in Cargo Pump Room, 01 forward superstructure Port side. Rectify prior to caro discharge operations to the satisfaction of RO/Flag and U.S. Coast Guard. - 74 SOLAS (20), II-1/45.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2023
Resolution: Six light fixture lenses replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 19 May 2022
Resolved
A system for continuous monitoring of the concentration of hydrocarbon gases shall be fitted. Vessel reported that their fixed hydrocarbon detection system for vent trunk and pump room was inoperable.
74 SOLAS (09) II-2/4.5.10.1.3
Action required: 60 - Rectify deficiencies prior to movement
Due 19 May 2022
Resolved 23 May 2022
Resolution: Vessel provided class report attesting to repair of the fixed hydrocarbon detection system.