NS LION

NS LION is a 2007 tank ship. The Coast Guard has recorded 3 inspections since 2019, most recently in January 2020, along with 1 deficiency.

Records from 2019 to 2020. Most recent: inspection, 3 January 2020.

Built
2007
Last inspected
3 January 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9339313
1022551
Flag
LIBERIA
Maury page id
psix-1022551

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 2 calendar years (2019–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it61449 - Convention (Subpart B), Gross Ton
35396 - Convention (Subpart B), Net Ton
115831 - Dead Weight, Metric Ton
133332 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

3 January 2020 ISPS III Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6882083
16 January 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6611279
3 January 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6605047

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 3 January 2019 Resolved
General arrangements plans shall be permanently exhibited for the guidance of ship's officers, showing clearly for each deck, the control stations, the various fire sections enclosed by "A" class divisions. The fire control plan does not diferentiate between "B" class boundaries and "A" class boundaries. "A" class boundaries are shown in yellow on the fire control plan.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 January 2019
Resolution: VESSEL CORRECTED THE FIRE CONTROL PLAN AND SENT IN PICTURES.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.