GALEN is a 2007 freight ship. The Coast Guard has recorded 38 inspections since 2016, most recently in September 2025, along with 8 deficiencies and 5 operational controls.
Records from 2016 to 2025. Most recent: inspection, 12 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it28142 - Dead Weight, Metric Ton 37864 - Displacement, Metric Ton 22914 - Convention (Subpart B), Gross Ton 9277 - Regulatory (Subpart C or D), Net Ton 9277 - Convention (Subpart B), Net Ton 22914 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
38 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 5 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 38
12 September 2025PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8229579
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 February 2025Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three consecutive starts. PSCOs observed the primary starter for the edg as non-functional.
74SOLAS(2004) II-1/44.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2025
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. PSCOs observed oily water separator as non-operational.
MARPOL Annex I/14.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2025
Resolved 18 March 2025
Resolution: Received class docs attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 March 2024Resolved
THE FIXED FIRE DETECTION AND FIRE ALARM SYSTEM SHALL BE SO DESIGNED AND THE DETECTORS SO POSITIONED AS TO DETECT RAPIDLY THE ONSET OF FIRE IN ANY PART OF THOSE SPACES AND UNDER NORMAL CONDITIONS OF OPERATION OF THE MACHINERY AND VARIATIONS OF VENTILATION. PSCO OBSERVED VENTILATION DIRECTED AT A SMOKE DETECTOR AFT OF THE GENERATORS IMPARING THE SMOKE DETECTOR'S OPERATION.
74 SOLAS (04) II-2/7.4.2
50AC
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2024
Resolved 27 March 2024
Resolution: The smoke detector was relocated outside the reach of the ventilation ducts flow and in compliance with the spacing requirements of SOLAS/FSS Code Ch.9 Reg.2.4.2 Table 9.1 and the smoke detector was tested satisfactorily. Docs uploaded.
Oil filterring equipment referred to in paragraph 1 of this regulation shall be of a design approved by the administration. oil filtering equipment has a small leak securred by gasket material and a ratchet strap.
MARPOL78(17 Cons.) annex 1 reg. 14.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 6 December 2021
Resolution: Class sent in documentation attesting to the correction of the deficiency
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 December 2021Resolved
Two sets of steel ladders, as widely separated as possible, keadibg to doors in the upper part of the space, similarly separated and from which access is provided to the open deck. One of these ladders shall be located within a protected enclosure that satisfies regulation 9.2.2.3.
The bulkhead on the outside of emergency escape ladder compartment located in the engine room is missing approximately.5 by.1 square meter of protective insulation
SOLAS 74(04 Cons.)Ch II-2 / REG 13.4.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 6 December 2021
Resolution: Class sent in documentation attesting to the correction of the deficiency
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 November 2020Resolved
Means shall be provided to control leaks of flammable liquids. PSCOs observed excessive oil accumulation around the main engines, generator, and in the oil purifier room.
74 SOLAS (04) 11-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2020
Resolved 3 December 2020
Resolution: The vessel has cleaned the engine room and repaired the leaks which caused the oil accumulation.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 December 2017Resolved
The fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. The detection for the hyper mist system could not be tested due to unknown control panel malfunction. SOLAS 74 (2009) II-2/14.2.1.1.2 (17ac) *See narrative for change to code 15ac.
Action required: 15 - Rectify deficiencies by next port
Due 10 December 2017
Resolved 8 December 2017
Resolution: PSCOs witnessed satisfactory test of hyper mist system in remote and local in 2 locations.
Each vessel of 10,00 gross tons or more must have a second marine radar system that operates independently of the first. S-Band Radar Inoperable. 33CFR164.37(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2017
Resolved 21 June 2017
Resolution: See attached technician's report.